HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 8018-2015 English PDF

US$339.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 8018-2015: Determination of oxidation stability of gasoline -- Induction period method
Status: Valid

GB/T 8018: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 8018-2015English339 Add to Cart 3 days [Need to translate] Determination of oxidation stability of gasoline -- Induction period method Valid GB/T 8018-2015
GB/T 8018-1987English359 Add to Cart 3 days [Need to translate] Gasoline. Determination of oxidation stability. Induction period method Obsolete GB/T 8018-1987

PDF similar to GB/T 8018-2015


Standard similar to GB/T 8018-2015

GB 6537   GB/T 2430   GB/T 8019   GB/T 8020   

Basic data

Standard ID GB/T 8018-2015 (GB/T8018-2015)
Description (Translated English) Determination of oxidation stability of gasoline -- Induction period method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard E31
Classification of International Standard 75.160.20
Word Count Estimation 16,133
Date of Issue 2015-12-31
Date of Implementation 2016-06-01
Older Standard (superseded by this standard) GB/T 8018-1987
Regulation (derived from) State Standard Announcement 2015 No.43
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 8018-2015: Determination of oxidation stability of gasoline -- Induction period method

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of oxidation stability of gasoline - Induction period method ICS 75.160.20 E31 National Standards of People's Republic of China Replacing GB/T 8018-1987 Determination of oxidation stability of gasoline - Induction period method Issued on. 2015-12-31 2016-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 8018-1987 "Determination of oxidation stability of gasoline (induction period method)" This standard GB/T 8018-1987 Compared to the main changes are as follows. --- Standard name from "Determination of oxidation stability of gasoline (induction period method)" was changed to measuring the induction period "of the oxidation stability of gasoline law"; --- To increase the "scope" section (see Chapter 1); --- SI units, remove the imperial units, such as pressure is measured in kilopascals (kPa), the temperature in degrees Celsius (℃); --- Added "Normative references" (see Chapter 2); --- Turning point for the definition of the description made changes and 13.8kPa modify 14kPa (see 31, 1987, version 2.1.); --- Added "Method" (see Chapter 5); --- On the thermometer more options (see 62, 1987, version 3.2.); --- Of toluene purity requirement was amended, the "chemically pure" to "analytical grade or purity ≥99%" (see 7.1, 1987 edition 4.1); --- Increased the oxygen purity requirements "pure oxygen, or purity ≥99.6%" (see 7.4); --- An increase of Chapter 8 sample content; --- The cleaning liquid detergent choose to rewrite the text from the comment section, and washing steps and requirements has been modified (see 9.1,1987 In version 5.1); --- For sample loading sequence has been modified (see 101, 1987 version 6.1.); --- Pressure conditions were changed as 7kPa instead of 6.89kPa, 14kPa instead of 13.8kPa, 690kPa ~ 705kPa replaced 689kPa (or 689kPa ~ 703kPa) and so on (see Chapter 10 and Appendix A, 1987 edition of Chapter 6 and Appendix A); --- Pressure release rate was amended to require "the release time of less than 2min" (see 10.1 and 10.4, and 6.1 of the 1987 edition 6.4); --- Complements the termination of the test conditions (see 10.2); --- Oxygen bomb cooling methods were more detailed requirements (see 10.4); --- Calculation expression induction period had been revised (see 112, 1987 version 7.1 and 7.2.); --- The report was amended to require the measurement results taken integer value (see 12.1, Chapter 9, 1987 edition). If the test is stopped When the turning point was not observed in case of the test reporting requirements see 12.2 and 12.3; --- On precision requirements was amended to supplement the applicable conditions (see 131, Chapter 8, 1987 edition.); --- To increase the "standard deviation has not been determined" (see 13.2); --- Appendix A.1 oxygen bomb and related accessories Figure A.1 have changed, more length requirement is a range. Oxygen bomb materials provided Appendix A.3 --- there are changes to a glass vial and cap size requirements, a range of values greater length requirements (see A.3 and Figure A.2 and Legend, 1987 edition of A.3 and A.2); --- Appendix A increased the pressure relief valve of claim (see A.5); --- Appendix A partial oxidation bath require the installation of non-self-resetting thermostat to prevent the liquid bath burned dry, and provides additional oxidation bath --- Appendix A provides more choices for the thermometer (see A.10); --- Remove Appendix B; --- Remove Appendix C, prevention of toluene is described in sections 7.1, chromic acid lotion precautionary statements, see 9.1; --- Increase the informative Appendix B, providing a solid sample bath temperature calibration methods. This standard uses redrafted Law Revision using American Society for Testing Materials Standards ASTMD525-12a "Determination of oxidation stability of gasoline France (induction period method). " This standard when using ASTMD525-12a made some modifications. The main technical difference between the Standard and ASTMD525-12a Isobutyl and the following reasons. --- Increase the range of the car with ethanol content of gasoline, "This standard applies to motor gasoline, ethanol gasoline in tune oil and car components Ethanol to gasoline and other products "; --- The ASTMD525-12a range 1.1 warnings noted in A.5; the Note 2 will indicate in its 13.1; remove its scope in Off warning of mercury; --- For Normative references This standard adopts the ASTM standard and our respective standards (see Chapter 2); --- Thermometer specifications for an increase of the standard requirements (see 6.2 and A.10); --- Increased in the instrument "50mL graduated cylinder" (see Chapter 6); --- Clear toluene, acetone, oxygen purity level (see Chapter 7); --- In Chapter 8 Sampling adds the sampling should be dark manganese-containing gasoline sample content; --- Increased 9.1 warnings for safe use of strong oxidants such as chromic acid to provide information; --- The ASTMD525-12a in "through until the oxygen pressure of 690kPa ~ 705kPa" to "slow bubbling of oxygen until the pressure Lida 690kPa ~ 705kPa "(see 10.1); --- Of ASTMD525-12a "when the induction period than the time required for the product can also stop the test," the standard for the representation Was amended to read "If the sample has a specific product specifications, when the test exceeds the corresponding observation time, but the turning point has not yet Appears, then the test can be stopped as needed "(see 10.2); --- Increasing the "total pressure" is defined in 12.3; --- Removed ASTMD525-12a Keywords chapter; --- A.1.4 in the steel oxygen bomb material specifications meet the increased requirements of the relevant standards of content; --- A.9 Note content added "electric heating bath temperature of the sample calibration method can refer to Appendix B". This standard by the National Standardization Technical Committee on products and lubricant oil (SAC/TC280) proposed. This standard by the National Standardization Technical Committee of petroleum products lubricants oil and lubricants and fuels Technical Committee (SAC/TC 280/SC1) centralized. This standard was drafted. China Petroleum & Chemical Corporation Research Institute of Petroleum. Participated in the drafting of this standard. Dalian Petroleum Instrument Co., Ltd. The main drafters of this standard. Liu Qian, Cheng Yu, Shen Zheng, Wangen Jie. This standard replaces the standards previously issued as follows. --- GB/T 8018-1987. Determination of oxidation stability of gasoline - Induction period method Warning --- application of this standard may involve some hazardous materials, operations and equipment. But not for all safety related thereto Full issues recommendations. Before using this standard has the responsibility to develop appropriate safety and health practices and determine the relevant regulatory restrictions Applicability.

1 Scope

This standard specifies the method for determination under accelerated oxidation conditions of oxidation stability of gasoline. This standard applies to motor gasoline, ethanol gasoline blending components of oil and ethanol gasoline and other products. NOTE. The method for determining the potential of glial measuring the oxidation stability of gasoline, reference SH/T 0585.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 514-2005 petroleum products Glass liquid thermometer technical conditions GB/T 4756 petroleum liquids hand sampling method GB/T 20878-2007 stainless steel and heat-resistant steel grades and chemical composition ASTME1 ASTM standard glass thermometer liquid (SpecificationforASTMliquidinglassthermometers) IP Petroleum and related products - Test methods for analyzing Standard Series Appendix A IP standard thermometer Specification (IPStandardmethods foranalysisandtestingofpetroleumandrelatedproducts-AppendixA. Specifications-IPstandard thermometers)

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 Turning point breakpoint Pressure - that in 15min pressure drop reached this point before the time curve 14kPa, at this point 15min after the pressure drop Not less than 14kPa, it is the turning point. 3.2 Induction period inductionperiod From the oxygen bomb placed in 100 ℃ bath to a turning point between the elapsed time in minutes (min) Fig. 4. Summary Oxidation of the sample in an oxygen bomb, this bomb first oxygen at 15 ℃ ~ 25 ℃ under the charge of oxygen to 690kPa ~ 705kPa, then at 98 ℃ ~ 102 ℃ Under heating conditions. Predetermined time interval pressure reading, pressure or continuous recording until you reach the turning point. Sample needed to reach the turning point The induction time is measured under the test temperature. Thus the measured induction period can be calculated during the induction phase 100 ℃.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 8018-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 8018-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 8018-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 8018-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 8018-2015?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 8018-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.