US$314.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7940.2-2008: Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector Status: Valid GB/T 7940.2: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 7940.2-2008 | English | 314 |
Add to Cart
|
3 days [Need to translate]
|
Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector
| Valid |
GB/T 7940.2-2008
|
GB/T 7940.2-2001 | English | 599 |
Add to Cart
|
3 days [Need to translate]
|
Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector
| Obsolete |
GB/T 7940.2-2001
|
PDF similar to GB/T 7940.2-2008
Basic data Standard ID | GB/T 7940.2-2008 (GB/T7940.2-2008) | Description (Translated English) | Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | J20 | Classification of International Standard | 23.100.50 | Word Count Estimation | 16,158 | Date of Issue | 2008-06-25 | Date of Implementation | 2009-01-01 | Older Standard (superseded by this standard) | GB/T 7940.2-2001 | Quoted Standard | GB/T 3505-2000; GB/T 10610-1998; GB/T 17446-1998; ISO 11727 | Adopted Standard | ISO 5599-2-2001, IDT | Regulation (derived from) | National Standard Approval Announcement 2008 No.10 (Total No.123) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies five with optional pneumatic electrical connector port directional control valve, when the maximum working pressure of 1. 6MPa, the mounting surface requirements are as follows: the mounting surface dimensions and tolerances, identify air inlet, controlling mechanism driving the results of identification, optional size electrical connector, tolerances and specifications. |
GB/T 7940.2-2008: Pneumatic fluid power -- Five-port directional control valves -- Part 2: Mounting interface surfaces with optional electrical connector ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Pneumatic fluid power Five-port directional control valves Part 2. Mounting interface surfaces with optional electrical connector
ICS 23.100.50
J20
National Standards of People's Republic of China
GB/T 7940.2-2008/ISO 5599-2.2001
Replacing GB/T 7940.2-2001
Five - port directional control pneumatic valves
Part 2. with optional electrical connector mounting surface
(ISO 5599-2.2001, IDT)
Posted 2008-06-25
2009-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 7940 under the "Air Five - port directional control valves," the general title, includes the following components.
--- Part 1. Mounting interface surfaces without electrical connector;
--- Part 2. mounting surface with optional electrical connector.
This section GB/T Section 27940, and is identical with ISO 5599-2.2001/Amd. 1.2004, Cor. 1.2007 "gas
Voltage drives - Five - port directional control valves - Part 2. base with optional electrical connector mounting surface "(in English) on the pair
GB/T 7940.2-2001 "Air Five - port directional control valves - Part 2. mounting surface with optional electrical connector" of revisions.
This part of ISO 5599-2.2001 has the following important differences.
--- "2 Normative references" and "references" to replace the corresponding national standards with international standards.
This portion of the GB/T 7940.2-2001 main differences.
--- On the "2" in the reference document was revised and updated.
--- Add "5.5 port for gas identification, additional options according to ISO 11727 to develop."
--- Add "indicator 6.3.4 can be used and/or anti-surge circuit, but should not be polarization sensitive."
This part is proposed by China Machinery Industry Federation.
This part of the National Standardization Technical Committee of hydraulic and pneumatic (SAC/TC3) centralized.
This section is drafted. Pneumatic Co., Ltd. Wuxi Institute of Technology, Beijing Institute of Technology, Industrial Automation Equipment Co., Ltd. Ningbo Sono.
The main drafters of this section. Yang Sui Ran, Lee Enterprises aryl, Zhanglian Ren Peng positive light, Wu Dengkui unit Ning.
This part of the standard replaces the previous editions are.
--- GB/T 7940-1987, GB/T 7940.2-2001.
GB/T 7940.2-2008/ISO 5599-2.2001
Introduction
In the pneumatic system, the power is through a closed loop control and compressed air to pass.
Various devices for distribution and control of gas can be installed directly in the pipeline or on the interface to quickly remove or replace.
Five - port directional accordance with the requirements of this section and installation at the interface of the control valve, its function is to control the flow of compressed gas.
When the valve is electrically driven, it is necessary to electrical connector mounted on the valve body. If you are using a standard electrical connector, a user-friendly valve,
Different manufacturers of connectors can be interchanged.
To this end, the provisions of the air intake port identification and control, control of body movements result of identification, dimensions and tolerances of the mounting surface, to mention
High provisions in this section of the interchangeability of pneumatic directional control valves.
GB/T 7940.2-2008/ISO 5599-2.2001
Five - port directional control pneumatic valves
Part 2. with optional electrical connector mounting surface
1 Scope
GB/T 7940 provisions of this part of the Five - port directional pneumatic with optional electrical connector of the control valve when the maximum operating pressure
1.6MPa, its mounting surface requirements are as follows.
--- Mounting surface dimensions and tolerances;
--- Identify air inlet;
--- Control mechanism driving the results of identification;
--- Optional electrical connector dimensions, tolerances and specifications.
2 Normative references
The following documents contain provisions which, through GB/T reference in this 7940 constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
Terminology GB/T 3505-2000 Geometrical Product Specifications Surface texture Profile method of surface structure, definitions and parameters (eqv
ISO 4287.1997)
GB/T 10610-1998 Geometrical product specifications, surface structure, rules and methods for the assessment of surface structure contour law (eqv ISO
4288.1996)
GB/T 17446-1998 fluid power systems and components term (idt ISO 5598. 1985)
ISO 11727 Pneumatic control valves and other components of the air intake, control identification mechanism
3 Terms and Definitions
GB/T 17446 and established the following terms and definitions apply to this section.
3.1
The device consists of two parts (plug and socket) composition, when they are connected, continuous connecting role of electrical and mechanical.
3.2
Current-carrying element is movable circuit.
3.3
Designed with openings or recesses can be mechanical clamping pin female contacts.
3.4
Designed to match the jacket and plug the male contacts.
3.5
Designed to locate, and to ensure that the contact element contacts and corresponding insulation function devices.
GB/T 7940.2-2008/ISO 5599-2.2001
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7940.2-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 7940.2-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 7940.2-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7940.2-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 7940.2-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7940.2-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|