US$494.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7341.1-2010: Electroacoustics -- Audiological equipment -- Part 1: Pure-tone audiometers Status: Valid GB/T 7341.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 7341.1-2010 | English | 494 |
Add to Cart
|
4 days [Need to translate]
|
Electroacoustics -- Audiological equipment -- Part 1: Pure-tone audiometers
| Valid |
GB/T 7341.1-2010
|
| GB/T 7341.1-1998 | English | 759 |
Add to Cart
|
3 days [Need to translate]
|
Audiometers. Part 1: Pure-tone audiometers
| Obsolete |
GB/T 7341.1-1998
|
| GB/T 7341-1987 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Audiometer
| Obsolete |
GB/T 7341-1987
|
PDF similar to GB/T 7341.1-2010
Basic data | Standard ID | GB/T 7341.1-2010 (GB/T7341.1-2010) | | Description (Translated English) | Electroacoustics -- Audiological equipment -- Part 1: Pure-tone audiometers | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A59 | | Classification of International Standard | 17.140.50 | | Word Count Estimation | 25,22 | | Date of Issue | 2010-12-01 | | Date of Implementation | 2011-05-01 | | Older Standard (superseded by this standard) | GB/T 7341.1-1998 | | Quoted Standard | GB/T 3785.1; GB/T 4854.1; GB/T 4854.3; GB/T 4854.4-1999; GB/T 4854.7; GB/T 4854.8; GB/T 7341.2; GB/T 7583; GB/T 7584.1; GB/T 9001; GB/T 9706.1; GB/T 15951; GB/T 16296; GB/T 16402; GB/T 16403-1996; GB/T 17696; GB/T 48545; IEC 60318-2-1998; IEC 60318-5; IEC 60601-1-2; IEC 60601-1-4; IEC 60318-4; GB/T 25498.1; GB/T 25498.3-2010 | | Adopted Standard | IEC 60645-1-2001, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 9, 2010 (No. 164 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the general requirements for audiometer, and the use of psycho-acoustic test method, with the standard reference hearing threshold level compared to the design for the determination of hearing threshold level of the pure tone audiometer specific requirements. |
GB/T 7341.1-2010: Electroacoustics -- Audiological equipment -- Part 1: Pure-tone audiometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electroacoustics Audiological equipment Part 1. Pure-tone audiometers
ICS 17.140.50
A59
National Standards of People's Republic of China
Replacing GB/T 7341.1-1998
Electroacoustic audiometry equipment
Part 1. pure tone audiometer
Part 1. Pure-toneaudiometers
(IEC 60645-1.2001, IDT)
Issued on. 2010-12-01
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
Type 4 is fixed to a predetermined frequency audiometer of claim 4
General requirements 5 5
6 test signal source 7
7 Speaker Output 10
8-level control signal 10
9 References pure tone 13
10 Calibration 13
11 electrical signal output 14
12 audiogram format 14
13 Regulatory Compliance verification and test procedures 14
14 maximum permitted expanded uncertainty of measurement 17
15 signs and instructions 17
References 19
Figure 1 Test tone rise, fall envelope 12
Table 1 Fixed frequency audiometer minimum functional requirements 5
The lowest frequency and hearing level ranges Table 2 fixed-frequency audiometer should provide claim 7
Table 3 is pressed ear type, ear type, the percentage of insert earphones and bone vibrator Used sound pressure or vibration force represents the maximum allowable acoustic signals
THD 8
Table 4 narrowband masking noise. band center frequency sound pressure than low 3dB spectral density level of the lower cut-off frequency bandwidth of 9
Table 5 hearing zero level reference standards 14
Table 6 illustrates the threshold level of 14 symbols
Umax basic measurement value table 7 of 17
Foreword
GB/T 7341 "electro-acoustics audiometric equipment" is divided into five sections.
--- Part 1. pure tone audiometry (GB/T 7341.1);
--- Part 2. Language audiometric equipment (GB/T 7341.2);
--- Part 3. for audiometric and neuro - otological Auditory test signals of short duration (GB/T 7341.3);
--- Part 4. extension of the high-frequency hearing test equipment (GB/T 7341.4);
--- Part 5. ear acoustic impedance/admittance measuring instruments (GB/T 15953).
This section GB/T 17341 Part of.
This section identical with IEC 60645-1.2001 "electro-acoustics audiometric equipment - Part 1. pure tone audiometer" (second edition). Headquarters
The following sub-national standards referenced in the content and IEC 60645-1.2001 "electro-acoustics audiometric equipment - Part 1. pure tone audiometry
Meter "(second edition) content equivalent to.
a) GB/T 4854.3 acoustic calibration of audiometric equipment - Reference zero - Part 3. pure tones and bone vibrators Reference equivalent threshold force levels
(Eqv ISO 389-3);
b) GB/T 7583 Acoustics pure tone air conduction audiometry hearing protection (eqv ISO 6189);
c) GB/T 9001 Methods of measurement of audio amplifier (eqv IEC 60268-3);
d) GB/T 16296 Acoustics - Audiometric test methods - Part 2. Sound field with pure tone and narrow-band test signals audiometry (eqv ISO 8253-2);
e) GB/T 16402 Acoustics pure tones and insert earphones Reference equivalent threshold sound pressure levels (eqv ISO 389-2);
f) GB/T 16403-1996 Acoustics pure tone audiometry method air conduction and bone conduction threshold audiometry basic (eqv ISO 8253-1.
1989);
g) GB/T 17696 Acoustics - Audiometric test methods - Part 3. Language audiometry (eqv ISO 8253-3).
The partial substitution of GB/T 7341.1-1998 "Audiometers - Part 1. pure tone audiometer."
Compared with the previous version of this part of the great technological changes are technical reprint. The major changes are.
a) the original audiometer functional facilities from five kinds of patterns to four kinds of patterns;
b) adds the following.
1) acoustic safety requirements, pressure requirements and frequency modulation characteristics requirements;
2) an external signal source frequency response requirements;
3) the speaker sound field audiometry requirements and free-field conditions;
Requirement 4) the electrical signal output, audiogram format requirements;
5) the use of various types of transducers and corresponding reference ear simulator calibration and use of equivalent threshold sound pressure levels to ensure alignment
About the standard measurement method number;
6) The maximum allowable expanded uncertainty of measurement;
c) cancel the broadband noise as masking noise;
d) the performance indicators and testing methods to separate provisions.
For ease of use, this section made the following editorial changes.
a) with "this Part" instead of the "standard";
b) use a decimal point instead of a decimal comma ",". ",";
c) Normative references chapter introductory phrase modification according to the provisions GB/T 1.1-2000 of;
d) IEC and ISO international standards in this part of the normative references and references to other sections are in force with the corresponding
National standards in place;
e) reference documents "IEC 60711" after the revision to "IEC 60318-4" so with "IEC 60318-4" instead of "IEC 60711";
f) reference files "IEC 60126" amended to "IEC 60318-5" so with "IEC 60318-5" instead of "IEC 60126".
This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This part of the National Standardization Technical Committee electro-acoustics (SAC/TC23) centralized.
This section is responsible for drafting. Shanghai Institute of Measurement and Testing.
Participated in the drafting of this section. Institute of Otolaryngology, Chinese PLA General Hospital, China Institute of Metrology.
The main drafters of this section. Gujian Xiu, Chen Hongwen, Anzhao Liang, Qiu Jianhua.
This part of the standard replaces the previous editions are.
--- GB/T 7341-1987;
--- GB/T 7341.1-1998.
Introduction
With the development of the field to diagnose hearing, hearing protection and rehabilitation for the purpose of the test levels, making use of the audiometer greatly increase
plus. This allows to consider the audiometer as a series of specific independent functional units. By the provisions of these functional units will be able to make provisions
The performance of various types of hearing devices with these units. GB/T 7341 comprises a series of parts, of which GB/T 7341.1 is the first in this series
Part summarizes the pure tone audiometer requirements.
Because Expand GB/T 7341 following several parts, now, this section only defines a pure tone audiometer required range. This section
The point is that without a broadband noise as a masking noise signal. Broadband is now used only for masking noise signal associated with the language section,
7341.2 as described in GB/T .
The performance version will be separated from the test prescribed requirements out, the purpose is to prove its consistency. Only when the test lab
Actual expanded uncertainty of measurement results comply with the technical requirements of this section in order to be verified. This section Table 7 shows the maximum permissible expansion
Exhibition uncertainty Umax values. Based on this basic phase, audiometer manufacturer to meet the tolerance and GB/T 7341.1-1998 prescribed
with. Compared with the previous version, suitable for use in the audiometer tolerance increased Umax.
Electroacoustic audiometry equipment
Part 1. pure tone audiometer
1 Scope
This section provides general requirements audiometer, and the test method employs psychoacoustic by standard reference hearing threshold level of comparison
Designed for the specific requirements of measuring hearing threshold level of pure tone audiometer.
The purpose of this section is intended to ensure that.
a) comply with the requirements of this audiometer is different, according to GB/T 16403 and GB/T 7583 the method described, for nominee
Ear for hearing test in the frequency range 125Hz ~ 8kHz, especially audiometry should be able to obtain substantially the same result;
b) The results represent the baseline hearing test ear hearing a valid comparison between the threshold;
c) audiometer test signal generated scope, operation or testing of auditory function range of complexity are classified according to their.
2 Normative references
The following documents contain provisions which, through reference to GB/T 7341 to the present, constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 3785.1 electric acoustic sound level meters - Part 1. Specification (GB/T 37851.1-2010, IEC 61672-1.2002,
IDT)
GB/T 4854.1 acoustic calibration of audiometric equipment - Reference zero - Part 1. the ear headphones pure tone reference equivalent threshold sound pressure levels
(GB/T 4854.1-2004, ISO 389-1.1998, IDT)
GB/T 4854.3 Reference zero - Part 3 Acoustics calibration of audiometric equipment. pure tones and bone vibrators Reference equivalent threshold force levels
(GB/T 4854.3-1998, eqv ISO 389-3.1994)
GB/T 4854.4-1999 Acoustics calibration of audiometric equipment - Reference zero - Part 4. Reference levels for narrow-band masking noise (idt
ISO 389-4.1994)
GB/T 4854.7 acoustic calibration of audiometric equipment - Reference zero - Part 7. free field reference diffuse - field listening and hearing threshold
(GB/T 4854.7-1999, idt ISO 389-7.1996)
GB/T 4854.8 Reference zero for the Section 8 acoustic calibrator audiometric equipment. Headphones pure tone reference equivalent threshold sound pressure levels
(GB/T 4854.8-2007, ISO 389-8.2004, IDT)
GB/T 7341.2 Audiometers - Part 2. Language audiometric equipment (GB/T 7341.2-1998, idt IEC 60645-2.1993)
GB/T 7583 Acoustics pure tone air conduction audiometry --- Hearing Protection (GB/T 7583-1987, eqv ISO 6189. 1983)
GB/T 7584.1 Hearing protectors - Part 1. Subjective method for measurement of sound attenuation (GB/T 7584.1-2004, ISO
4869-1.1990, IDT)
GB/T 9001 audio amplifier measurement method (GB/T 9001-1988, eqv IEC 60268-3. 1983)
GB/T 9706.1 Medical Electrical Equipment Part 1. General requirements for safety (GB/T 9706.1-2007, IEC 60601-1.
1988 A1.1991 A2.1995, IDT)
GB/T 15951 measurements on bone vibrators force coupler (GB/T 15951-1995, idt IEC 60373.1990)
GB/T 16296 Acoustics - Audiometric test methods - Part 2. Sound field audiometry with pure tone and narrow-band test signals (GB/T 16296-
1996, eqv ISO 8253-2.1992)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7341.1-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 7341.1-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 7341.1-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7341.1-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 7341.1-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7341.1-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|