US$114.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7130-2016: Plastics -- Phenol-formaldehyde moulding -- Determination of free phenols -- Iodometric method Status: Valid GB/T 7130: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 7130-2016 | English | 114 |
Add to Cart
|
3 days [Need to translate]
|
Plastics -- Phenol-formaldehyde moulding -- Determination of free phenols -- Iodometric method
| Valid |
GB/T 7130-2016
|
GB/T 7130-1986 | English | 159 |
Add to Cart
|
2 days [Need to translate]
|
Determination of free phenols in phenol-formaldehyde mouldings. Iodometric method
| Obsolete |
GB/T 7130-1986
|
PDF similar to GB/T 7130-2016
Standard similar to GB/T 7130-2016 GB/T 7139 GB/T 6670 GB/T 7141 GB/T 1040.1
Basic data Standard ID | GB/T 7130-2016 (GB/T7130-2016) | Description (Translated English) | Plastics -- Phenol-formaldehyde moulding -- Determination of free phenols -- Iodometric method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G31 | Classification of International Standard | 83.080.01 | Word Count Estimation | 6,689 | Date of Issue | 2016-06-14 | Date of Implementation | 2017-01-01 | Older Standard (superseded by this standard) | GB/T 7130-1986 | Quoted Standard | ISO 385; ISO 565; ISO 648 | Adopted Standard | ISO 119-1977, IDT | Regulation (derived from) | National Standard Announcement No. 8 of 2016 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the iodometric method for the semi-quantitative determination of free phenol content in phenolic moldings. The free phenol content of the molded article is mainly affected by the degree of curing. It is also important to determine the free phenol content when consideration must be given to contamination of food or other materials due to contact with the molded article. |
GB/T 7130-2016: Plastics -- Phenol-formaldehyde moulding -- Determination of free phenols -- Iodometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastics.Phenol-formaldehyde mouldings.Determination of free phenols.Iodometric method
ICS 83.080.01
G31
National Standards of People's Republic of China
Replace GB/T 7130-1986
Plastic phenolic molded products
Determination of free phenol by iodometric method
(ISO 119. 1977, IDT)
2016-06-14 release
2017-01-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 7130-1986 "Determination of free phenol in phenolic molded articles by iodometric method", and GB/T 7130-1986 phase
The main technical changes are as follows.
--- standard name changed to "plastic phenolic molded products free phenol determination iodometric method";
--- Added "preface";
--- removed the standard text "This standard is equivalent to the international standard ISO 119. 1977" plastic phenolic molding material free phenol
(See 1986 edition);
--- modify the reagent concentration unit, with "molar concentration" instead of "equivalent concentration" (see Chapter 3, 1986 edition of Chapter 3);
- the use of the test sieve has been removed (see 4.2, 1986, 4.2);
--- modified the formula (see Chapter 7, 1986, Chapter 7);
--- Remove the standard additional instructions.
This standard uses the translation method equivalent to ISO 119. 1977 "Determination of free phenol in plastic phenolic molded products by iodometric method".
And the normative reference in this standard international documents are consistent with the relationship between China's documents are as follows.
GB/T 12805-2011 Laboratory Glass Burettes (ISO 385..2005, NEQ)
GB/T 6005-2008 Basic dimensions of test sieve wire braid, perforated plate and electroformed sheet sieve
(ISO 565..1990, MOD)
GB/T 12808-1991 Laboratory glass instruments Single-line pipette (eqvISO 648..1997)
This standard is proposed by the China Petroleum and Chemical Industry Association.
This standard by the National Plastics Standardization Technical Committee Thermosetting Plastics Subcommittee (SAC/TC15/SC11) centralized.
The drafting of this standard. Shanghai Eurasian Synthetic Materials Co., Ltd., in the blue dawn Chemical Research and Design Institute Co., Ltd., the national synthetic resin
Quality Supervision and Inspection Center, Changshu Southeast Plastic Co., Ltd., Shaxian Hongsheng Plastic Co., Ltd., Shandong Shengquan Chemical Co., Ltd.
The main drafters of this standard. Chen Ziling, Liu Yong, Wang Yonggui, Li Wenjiang, Zhu Chunyu, Chen Jiwei, Chen Ling.
This standard was first published in December 1986, this time for the first revision.
Plastic phenolic molded products
Determination of free phenol by iodometric method
1 Scope
This standard specifies the iodometric method for semi-quantitative determination of free phenol content in phenolic molded articles.
Note. This standard does not provide an absolute amount of free phenol.
The free phenol content in the molded article is mainly affected by the degree of cure. When it is necessary to consider food or other due to contact with the molded article
When the material is contaminated, it is also important to determine the free phenol content.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
ISO 385 burette (Burettes)
ISO 565 test sieve wire mesh, perforated plate and electroformed sheet sieve basic dimensions (Testsieves-Woven
metalwireclothandpertoratedplate-Nominalsizesofapertures)
ISO 648 laboratory glass instrument single standard line pipette (Laboratoryglassware-One-markpipettes)
3 principle
The free phenol was extracted from the powder sample with hot water. The extract is iodized and acidified with iodine solution in the presence of sodium tetraborate. Then immediately use sulfur
Sodium titanate standard titration solution titrated excess iodine, starch solution as indicator. Assume that six iodine atoms are reacted with the phenol of each molecule
Should calculate the result.
4 reagent
Only the approved analytical reagent, distilled water or the same purity of water was used in the analysis.
4.1 Sodium tetraborate. (Na2B4O7 · 10H2O).
4.2 Sulfuric acid. c (
2H2SO4
) = 1 mol/L.
4.3 Iodine. c (
2I2
) = 0.025 mol/L.
In about 40 mL (500 g/L) of potassium iodide solution, 6.35 g of iodine was dissolved and diluted to 1000 mL with water.
4.4 sodium thiosulfate. standard titration solution, c (Na2S2O3) = 0.05mol/L.
4.5 Starch solution. 2.5 g/L.
5 instruments
General laboratory instruments and the following instruments.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 7130-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 7130-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 7130-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 7130-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 7130-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 7130-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|