|
US$134.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 7095.3-2008: Enamelled rectangular copper winding wires -- Part 3: Polyester enamelled rectangular copper wire, class 155 Status: Valid GB/T 7095.3: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 7095.3-2008 | English | 134 |
Add to Cart
|
3 days [Need to translate]
|
Enamelled rectangular copper winding wires -- Part 3: Polyester enamelled rectangular copper wire, class 155
| Valid |
GB/T 7095.3-2008
|
| GB/T 7095.3-1995 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Enamelled rectangtar wires. Part 3--Modified polyester enamelled rectangular copper wires, class 155
| Obsolete |
GB/T 7095.3-1995
|
| GB 7095.3-1986 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Enameled rectangular wires--Part 3: Polyester enameled rectangular copper wires with a temperature index of 155
| Obsolete |
GB 7095.3-1986
|
PDF similar to GB/T 7095.3-2008
Basic data | Standard ID | GB/T 7095.3-2008 (GB/T7095.3-2008) | | Description (Translated English) | Enamelled rectangular copper winding wires -- Part 3: Polyester enamelled rectangular copper wire, class 155 | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K12 | | Classification of International Standard | 29.060.10 | | Word Count Estimation | 7,767 | | Date of Issue | 2008-06-13 | | Date of Implementation | 2009-03-01 | | Older Standard (superseded by this standard) | GB/T 7095.3-1995 | | Quoted Standard | GB/T 7095.1-2008 | | Adopted Standard | IEC 60317-16-1990, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 10 of 2008 (total 123) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies 155 polyester resin-based single flat enamelled copper winding wire coating requirements. If they can retain the original chemical properties of the resin and meets all the requirements for enameled wire, the resin can be modified. 155 of the heat stage, which requires a minimum temperature index of 155, a heat shock temperature of at least 175��C. Corresponds to the temperature in Celsius temperature index is not recommended use temperature enameled wire, including the use of equipment because it depends on many factors, including the type. This part applies to the nominal size range of conductors: Broadside Size: Minimum 2. 00 mm, maximum 16. 00 mm, Narrow Size |
GB/T 7095.3-2008: Enamelled rectangular copper winding wires -- Part 3: Polyester enamelled rectangular copper wire, class 155 ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Enamelled rectangular copper winding wires Part 3. Polyester enamelled rectangular copper wire, class 155
ICS 29.060.10
K12
National Standards of People's Republic of China
GB/T 7095.3-2008/IEC 60317-16.1990
Replacing GB/T 7095.3-1995
Enamelled copper flat wire winding
Part 3. 155 polyester enamelled copper flat wire
(IEC 60317-16.1990, Specificationsforparticulartypesofwindingwires-
Part 16. Polyesterenameledrectangularcopperwire, class155, IDT)
Posted 2008-06-13
2009-03-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Definitions, test methods and appearance General 1
Size 4 1
5 Resistance 1
Elongation 1 6
7 spring angle 2
8 flexibility and adhesion 2
9 Thermal Shock 2
10 Softening 2
11 scratch 2
12 Solvent 2
13 Breakdown Voltage 2
14 Insulation Continuity 2
15 Temperature index 2
16 anti-freezing agent 2
17 solderable 2
18 heat or solvent bonding 2
19 2 dielectric loss factor
20 transformer oil resistant 2
21 3 Loss
23 pinhole test 3
30 3 Packaging
GB/T 7095.3-2008/IEC 60317-16.1990
Foreword
GB/T 7095-2008 "flat enamelled copper winding wires" is divided into seven parts.
--- Part 1. General requirements;
--- Part 2. 120 acetal enamelled copper flat wire;
--- Part 3. 155 polyester enamelled copper flat wire;
--- Part 4. 180 polyester enamelled copper flat wire;
--- Part 5. 240 aromatic polyimide enamelled copper flat wire;
--- Part 6.200 polyester or polyester-imide/polyamide-imide enamelled copper flat wire;
--- Part 7. Polyester enamelled copper flat wire.
This section GB/T 7095 Part 3.
This section identical with IEC 60317-16.1990 "Standard winding wires - Part 16. 155 polyester enamelled copper flat wire"
Version 2.0 (English) and amendments No. 1 (1997).
For ease of use, this section made the following editorial changes.
--- Remove the foreword and introduction of international standards;
--- With a decimal point '. 'Instead of a comma as the decimal point,' ';
--- Increased by 3.2 "look and feel";
--- Fixed IEC 60317-16.1990 in the editorial errors, complements Chapter 23, "pinhole test."
This section instead of the date of implementation of the GB/T 7095.3-1995.
Section compared with the GB/T 7095.3-1995, major changes in the following.
--- According to IEC 60317-16.1990 The structure and content of the GB/T 7095.3-1995 rewritten;
--- Conductor nominal size range and heat levels are listed in Chapter 1, "Scope";
--- Increased Chapter 3, "Definitions, test methods - General and appearance."
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.
This section is drafted. Shanghai Electric Cable Research Institute, four Chuan Jinrui Electric Co., Ltd., Wuxi City Island Wire Factory, Jiangsu Schindler
Wire Co., Ltd., Essex Magnet Wire (Tianjin) Co., Ltd., Shenyang Hongyuan Wire Co., Ltd., Shanghai copper line Yang Co.
the company.
The main drafters of this section. Alan Li, Yuan Qiong, Xu Jin law, Zhou Zhiyun, Yuan Weiguo, Yang Xu Qing, Liu Shunrong.
This part of the standard replaces the previous editions are.
--- GB/T 7095.3-1986, GB/T 7095.3-1995.
GB/T 7095.3-2008/IEC 60317-16.1990
Enamelled copper flat wire winding
Part 3. 155 polyester enamelled copper flat wire
1 Scope
GB/T 7095 provisions of this part of the polyester resin-based single coat enamelled copper flat wire winding requirements 155. As can be reserved
Chemical characteristics of the original resin and meet all the requirements of the provisions of enameled wire, the resin can be modified.
NOTE. chemically-modified resin is a variation of, or contain one or more additives to improve certain properties of the resin or its usage characteristics.
155 represents the thermal level, which requires a minimum temperature index of 155, a heat shock temperature of at least 175 ℃.
Corresponding to the temperature index temperature in Celsius is not recommended wire temperature, because it depends on the type of device in use include
Many factors within.
This section applies to a conductor nominal size range.
--- Broadside size. minimum 2.00mm, maximum 16.00mm;
--- Narrow size. minimum 0.80mm, maximum 5.60mm.
This section includes Level 1 and Level 2 film thickness enamelled copper flat wire, and is applicable to all specifications conductor.
A combination of size and narrow size broadside and wide/narrow ratio see GB/T 7095.1-2008.
2 Normative references
The following documents contain provisions which, through GB/T reference in this 7095 constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 7095.1-2008 flat enamelled copper winding wires - Part 1. General requirements (IEC 60317-0-2.2005, IDT)
3 Definitions, test methods and General Appearance
3.1 General definitions and test methods
General definitions and test methods see GB/T 7095.1-2008 Chapter 3.
If GB/T 7095.1-2008 in this section are contradictory to this section shall prevail.
3.2 Appearance
See GB/T 7095.1-2008 in Chapter 3.
4 Dimensions
See GB/T 7095.1-2008 in Chapter 4.
5 resistance
See GB/T 7095.1-2008 in Chapter 5.
6 Elongation
See GB/T 7095.1-2008 in Chapter 6.
GB/T 7095.3-2008/IEC 60317-16.1990
|