US$348.00 · In stock Delivery: <= 1 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 6496-2017: Test method of aerospace solar cells calibration Status: Valid GB/T 6496: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 6496-2017 | English | 348 |
Add to Cart
|
1 days [Need to translate]
|
Test method of aerospace solar cells calibration
| Valid |
GB/T 6496-2017
|
| GB/T 6496-1986 | English | 559 |
Add to Cart
|
4 days [Need to translate]
|
The general rules of astronautic solar cell calibration
| Obsolete |
GB/T 6496-1986
|
PDF similar to GB/T 6496-2017
Basic data | Standard ID | GB/T 6496-2017 (GB/T6496-2017) | | Description (Translated English) | Test method of aerospace solar cells calibration | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F12;V76 | | Classification of International Standard | 27.160; 49.140 | | Word Count Estimation | 28,244 | | Date of Issue | 2017-11-01 | | Date of Implementation | 2017-11-01 | | Older Standard (superseded by this standard) | GB/T 6496-1986 | | Regulation (derived from) | National Standard Announcement 2017 No. 29 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 6496-2017: Test method of aerospace solar cells calibration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of aerospace solar cells calibration
ICS 27.160; 49.140
F12; V76
National Standards of People's Republic of China
Replacing GB/T 6496-1986
Aerospace solar cell calibration method
Posted.2017-11-01
2017-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 calibration principle 2
4.1 Overview 2
4.2 Irradiance and spectral irradiance correction 3
4.3 temperature correction 3
5 equipment 3
5.1 General Requirements 3
5.2 solar cell short circuit current test equipment 3
5.3 solar temperature control and temperature measurement equipment 4
5.4 solar cell relative spectral response test equipment 4
5.5 ground direct sunlight irradiance test equipment 4
5.6 Ground sunshine spectral irradiance test equipment 4
5.7 sun tracker 4
5.8 Collimation tube 5
6 calibration test system 5
7 calibration procedures 7
7.1 standard solar cell samples and performance testing 7
7.1.1 Standard Solar Cell Sample 7
7.1.2 Standard solar cell sample performance test 8
7.2 Natural sunlight solar cell calibration test 8
7.2.1 Calibration of environmental conditions 8
7.2.2 Calibration Test Step 8
Calculation of calibration results 9
9 standard calibration of solar cells 9
10 Calibration Report 9
Appendix A (Informative) Solar cell altitude calibration method 10
Appendix B (Normative) AM0 standard sunlight spectral irradiance 16
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 6496-1986 "Aerospace solar battery with the general provisions of calibration." This standard and GB/T 6496-1986
Compared to the main technical changes are as follows.
--- Scope The multi-junction gallium arsenide solar cells to increase the corresponding sub-solar cell calibration (see Chapter 1);
--- Added "high-altitude aircraft calibration method" and "high-altitude balloon calibration method" (see Appendix A);
--- Reference ISO 15387.2005, updated AM0 standard sunlight irradiance distribution data (see Appendix B, 1986 edition
Appendix A);
--- The "direct sunlight on the ground calibration method" described by the standard appendix described in the standard text to be described in detail (see Chapter 4,
1986 edition Appendix B);
--- Removed the "Alpine Calibration Law" (see the 1986 edition of Appendix B);
--- Removed the terminology "AM0 calibration short-circuit current value" and "AM0 calibration value" (see 1986 edition of Appendix C).
This standard proposed by China Aerospace Science and Technology Corporation.
This standard by the National Aerospace Technology and Standardization Technical Committee (SAC/TC425) centralized.
This standard was drafted. Beijing Oriental Institute of Measurement and Testing, Shanghai Institute of Space Power, China Electronics Technology Group Corporation eighteenth
graduate School.
The main drafters of this standard. Yang Yiqiang, Zhang Yu, Lu Jianfeng, Ni Jiawei, Xiao Zhibin, Wang Li Gong, Liu Min, Xu Siwei, Liu Zhihong, Lu Runxi,
Su Xinguang, Ma Zhiyi, Zhang Mingzhi, Hu Zhiyuan, Li Zhen, Wu Kang, Mei Gaofeng, Cheng Shuo.
This standard replaces the standards previously issued as.
--- GB/T 6496-1986.
Introduction
Aerospace standard solar cells are used solar space solar array and solar array electrical performance test solar simulator irradiance set by
According to reports, access to an accurate standard aerospace a solar cell calibration results, is to ensure aerospace solar cells and solar array performance test
Accuracy of the premise.
GB/T 6496-1986 recommended in the two space a standard solar cell calibration method "ground sunshine spectroscopy" has been
Used by China's space system, and continue to improve and perfect. From.1990 to.2000, this method participated many times with NASA, ESA,
NASDA and other foreign space agency space standard solar cell comparison test to verify the accuracy and reliability of the method,
Surface direct sunlight calibration method, "the name was included in the international standard ISO 15387.2005" space system single junction solar cell measurement and calibration
Program "(Spacesystems-Single-junctionsolarcels-Measurementandcalibrationprocedures), is currently
The only method of calibration for standard solar cells in China that is internationally recognized as aerospace.
"Direct sunlight on the ground calibration method" the use of natural sunlight and mature universal equipment for AM0 solar cell calibration,
Technology is mature, low cost. The method can be used cavity absolute direct radiometer, high accuracy and can be traced directly to the world radiation center too
Yang irradiation benchmark, with high accuracy and reliability.
High-altitude and space calibration can be directly obtained solar cells in the real AM0 sunshine conditions of the calibration results, with higher accuracy.
Advanced space agencies abroad, "high altitude aircraft calibration method" "high altitude balloon calibration method" altitude calibration method has more than 50 years of experience,
The calibration of mountings carried out with satellites and space shuttles has also been carried out many times, and the work of calibrating the solar cells in the manned space station is also under planning
in. High-altitude and space calibration is also China's space solar cell calibration technology development.
Since.2000, China's research work on altitude and space calibration needs to be improved and improved in terms of methods, equipment and procedures. for
To promote the development of high altitude calibration technology in China, in line with the international advanced standards move closer to provide guidance for the future development, at the same time reflect our country
The status quo of the principle of technology, are listed in Appendix A of the international standard ISO 15387.2005 provides "high altitude balloon calibration method" and "high
Airplane calibration method "for China's space future space solar altitude calibration work to provide guidance.
GB/T 6496-1986 revision has adopted our own independent intellectual property rights internationally recognized calibration method, absorbing China's space too
Positive results of solar cell calibration technology over the years, not only reflects the status quo of our technology, but also consider the future development, and move closer to international advanced standards,
More operational and instructive, will be in China's space solar cell calibration technology development and space photovoltaic power system development, application
Play an active role in raising the level.
Aerospace solar cell calibration method
1 Scope
This standard specifies the use of direct sunlight on the ground approach to a standard solar cell calibration calibration principle, equipment, testing
Test systems and procedures.
This standard applies to aerospace with monocrystalline silicon, gallium arsenide standard solar cells and a multi-junction GaAs GaAs solar cell corresponding
Of a standard solar cell calibration, other types of space with standard solar cells, the ground with a standard solar cell calibration can refer to
carried out.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2297 solar photovoltaic energy system terminology
GB/T 6492 aerospace standard solar cells
GB/T 6495.4 crystalline silicon photovoltaic device Ⅰ-Ⅴ measured characteristics of temperature and irradiance correction method
GB/T 6495.8 Photovoltaic devices Part 8. Measurement of the spectral response of photovoltaic devices
ISO 15387-2005 space system single junction solar cell measurement and calibration procedures (Spacesystems-Single-junction
solarcels-Measurementsandcalibrationprocedures)
3 Terms and definitions
GB/T 2297 and defined by the following terms and definitions apply to this document.
3.1
A standard solar cell primarystandardsolarcel
Produced by the method specified, with the same relative spectral response of the solar cell under test, using the provisions of the other not based on standard solar
Calibration method of the pool of solar cells calibrated.
3.2
A standard solar cell primarystandardcomponentsolarcel
Produced by a predetermined method, having the same relative spectral response as the corresponding subcell of the multi-junction solar cell being tested, adopting a predetermined non-based
Other standard solar cell calibration methods have been calibrated for the solar simulator to set the appropriate wavelength band solar cells.
3.3
Space with solar cell calibration spacesolarcelcalibration
Determine whether a standard solar cell or standard sub-cell will short-circuit current at standard or true AM0 sunshine conditions and standard temperature
process.
3.4
AM0 sun conditions airmasszerosunlightcondition
The sunshine illumination conditions on the vertical plane with the sunshine ray at the average distance between the Earth 's surface and the atmosphere in the upper atmosphere.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 6496-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 6496-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically in 24 hours. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 6496-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6496-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 6496-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6496-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|