US$259.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 6314-2018: Internal micrometer with three-point contact Status: Valid GB/T 6314: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 6314-2018 | English | 259 |
Add to Cart
|
3 days [Need to translate]
|
Internal micrometer with three-point contact
| Valid |
GB/T 6314-2018
|
GB/T 6314-2004 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
Internal micrometer with three-point contact
| Obsolete |
GB/T 6314-2004
|
GB/T 6314-1986 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Three point internal micrometers
| Obsolete |
GB/T 6314-1986
|
PDF similar to GB/T 6314-2018
Basic data Standard ID | GB/T 6314-2018 (GB/T6314-2018) | Description (Translated English) | Internal micrometer with three-point contact | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | J42 | Classification of International Standard | 17.040.30 | Word Count Estimation | 13,162 | Date of Issue | 2018-05-14 | Date of Implementation | 2018-12-01 | Older Standard (superseded by this standard) | GB/T 6314-2004 | Regulation (derived from) | National Standards Announcement No. 6 of 2018 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 6314-2018: Internal micrometer with three-point contact---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Claw inner diameter micrometer)
ICS 17.040.30
J42
National Standards of People's Republic of China
Replace GB/T 6314-2004
Three-jaw inner diameter micrometer
Published on.2018-05-14
2018-12-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 6314-2004 "Three-claw inner diameter micrometer". This standard is compared with GB/T 6314-2004, except for editorial repair
In addition, the main technical changes are as follows.
--- Revised the scope of application of the standard (see Chapter 1, Chapter 1 of the.2004 edition);
--- Redefining related terms (see Chapter 3, Chapter 3 of the.2004 edition);
--- Re-specified the measurement range of the three-claw inner micrometer and its corresponding relationship with the range (see 4.3,.2004 edition 4.2);
--- Increased the requirement for measuring paw interaction (see 5.2);
--- Increased the requirements for the interchangeability of the three-claw inner micrometer probe (see 5.2.3);
--- Revised the requirements for materials required for measuring jaws and measuring heads (see 5.3, 5.2 of.2004 edition);
--- Increased the requirement for scale marking and its coincidence (see 5.4);
--- Added requirements for zero adjustment device, screw pair wear adjustment device and extension rod (see 5.5);
--- Revised the requirements for the force measuring device and its force measurement value (see 5.6, 5.3 of the.2004 edition);
--- Revised the requirements for the shape of the measuring surface and the hardness and surface roughness of the measuring surface (see 5.7.1, 5.7.4, 5.4.1 of the.2004 edition);
--- Increased the requirements for the shape of the special-purpose measuring surface and the requirements of the two-point measuring surface (see 5.7.2, 5.7.3);
--- Re-principle the principle of maximum allowable error and error determination of the indication (see 5.8, 5.7 of.2004 edition);
--- Redefined the technical requirements for the proofreading ring gauge (see 5.9, 5.7 of the.2004 edition);
--- Increased the requirements for inspection conditions (see Chapter 6);
--- Added the content of the inspection method, supplemented the appearance, interaction, scale marking and its coincidence, inspection and measurement of various devices
Inspection methods for items such as face (see Chapter 7);
--- Revised the test method for proofreading ring gauges, and unified with relevant standards (see 7.8,.2004 edition 6.2).
This standard was proposed by the China Machinery Industry Federation.
This standard is under the jurisdiction of the National Standardization Technical Committee for Measuring Instruments (SAC/TC132).
This standard is drafted by. Guilin Measuring Tool has limited liability company.
Participated in the drafting of this standard. Chengdu Tool Research Institute Co., Ltd., Harbin Measuring and Cutting Tool Group Co., Ltd., Suzhou McLean
Measurement Technology Co., Ltd., Guilin Guanglu Digital Measurement and Control Co., Ltd., Guangxi Zhuang Autonomous Region Metrology and Testing Institute, Liaoning Province Metrology Science Research
Research Institute.
The main drafters of this standard. Zhao Weirong, Li Xiaojun, Han Chunyang, Zhang Wei, Huang Xiaobin, Yan Lie Xue, Yang Mingzhu, Yang Bin.
The previous versions of the standards replaced by this standard are.
---GB/T 6314-1986, GB/T 6314-2004.
Three-jaw inner diameter micrometer
1 Scope
This standard specifies the terms and definitions, types and basic parameters of the three-claw inner micrometer (excluding the electronic digital three-claw inner micrometer).
Requirements, inspection conditions, inspection methods, signs and packaging.
This standard applies to scale readings and digital readings with a scale value of 0.001mm, 0.005mm, and an upper limit of the measurement range up to 300mm.
Claw inner micrometer (excluding electronic digital three-claw inner micrometer).
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1216-2018 outer diameter micrometer
GB/T 17163-2008 Geometrical quantity measuring instrument terminology basic terminology
GB/T 17164-2008 Geometric quantity measuring instrument terminology product terminology
GB/T 18779.1-2002 Specification for geometrical quantities of products (GPS) Measurements and measurements of workpieces and measuring equipment - Part 1.
Determination rules for passing or failing to pass the inspection
GB/T 24634-2009 Geometrical Product Specifications (GPS) General concepts and requirements for GPS measuring equipment
JB/T 11233-2012 Calibration ring gauge
3 Terms and definitions
GB/T 17163-2008, GB/T 17164-2008 and GB/T 24634-2009 define the following terms and definitions apply
In this document.
3.1
Three-jaw inner micrometer internalmicrometerwiththree-pointcontact
Using the principle of spiral pair, the three measuring claws are moved radially by rotating the tower-shaped Archimedes spiral or moving cone to make it and measured
Inner bore contact, inner diameter micrometer for measuring inner bore size.
Note. Rewrite GB/T 17164-2008, definition 2.3.16.
4 type and basic parameters
4.1 type
The three-claw inner micrometer is shown in Figure 1 and Figure 2. The illustrations are for illustration only and do not indicate the detailed structure.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 6314-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 6314-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 6314-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6314-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 6314-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6314-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|