US$374.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5654-2007: Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity Status: Valid GB/T 5654: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 5654-2007 | English | 374 |
Add to Cart
|
3 days [Need to translate]
|
Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity
| Valid |
GB/T 5654-2007
|
| GB/T 5654-1985 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Measurement of relative permittivity, dielectric dissipation factor at power frequency and volume resistivity of insulating liquids
| Obsolete |
GB/T 5654-1985
|
PDF similar to GB/T 5654-2007
Basic data | Standard ID | GB/T 5654-2007 (GB/T5654-2007) | | Description (Translated English) | Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K15 | | Classification of International Standard | 29.035.99 | | Word Count Estimation | 19,198 | | Date of Issue | 2007-12-03 | | Date of Implementation | 2008-05-20 | | Older Standard (superseded by this standard) | GB/T 5654-1985 | | Adopted Standard | IEC 60247-2004, IDT | | Regulation (derived from) | China Announcement of Newly Approved National Standards No. 12 of 2007 (No. 112 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the test temperature of liquid insulating material dielectric loss factor and relative permittivity and DC resistivity measurement method. This standard is not used as a reference test liquid, but also applies to the operation of the transformers, cables and other electrical equipment in the liquid. However, this standard applies only to single-phase liquid, as a routine method of measurement can be made to simplify the method described in Appendix C and. For non- hydrocarbon insulating liquids, require the use of other cleaning methods. |
GB/T 5654-2007: Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor and d.c. resistivity ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Insulating liquids. Measurement of relative permittivity, dielectric dissipation factor and dcresistivity
ICS 29.035.99
K15
National Standards of People's Republic of China
GB/T 5654-2007/IEC 60247.2004
Replacing GB/T 5654-1985
Liquid Insulation Materials
Relative permittivity, dielectric loss factor
And measure the DC resistivity
(IEC 60247.2004, IDT)
Posted 2007-12-03 2008-05-20 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is identical with 60247 IEC .2004 "to measure the liquid insulating material of relative permittivity, dielectric dissipation factor and dc resistivity
Amount "(in English).
For ease of use, this standard made the following editorial changes.
a) use the decimal symbol '. 'Decimal symbol instead of' ';
b) "this International Standard" be replaced by "this standard";
This standard replaces GB/T 5654-1985 "liquid insulating material frequency relative permittivity, dielectric loss tangent and volume resistivity
measuring".
The main changes compared to 5654-1985 standard and GB/T as follows.
a) The increase in the standard "Introduction" and "Normative References" section;
b) DC resistivity measurements, the "liquid withstand the test voltage 200V ~ 300V/mm" to "test voltage should be
Liquid withstand 250V/mm "; the power of time" 60s "to" 60s ± 2s "; the" Note the sample 15min after the start of measurement
Quantity "to" no more than 10min Start Measurement ";
c) This standard increased the Figs. 2, 3, 4, 5 in FIG.
This standard Annex A, Annex B, Annex C is informative appendix.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the National Standardization Technical Committee of the insulating material (SAC/TC51) centralized.
This standard was drafted. Guilin Institute of Electrical Science.
The main drafters of this standard. Wang Xianfeng.
This standard previously issued as follows.
--- GB/T 5654-1985.
GB/T 5654-2007/IEC 60247.2004
Introduction
Health and safety.
Warning. This standard does not address all the safety problems associated with the use of the use of this standard has the responsibility to establish appropriate health and safety
Rules and prior to use is determined by the scope of application of the rules of limitation.
surroundings.
This standard will result in some of the insulating liquid, chemicals, used oil contaminated solids in the sample container and other issues, these items
Disposal of the relevant regulations should be to reduce the environmental impacts and hazards, and should be ready every precaution to prevent these fluids due to desertion
polluted environment.
GB/T 5654-2007/IEC 60247.2004
Liquid Insulation Materials
Relative permittivity, dielectric loss factor
And measure the DC resistivity
1 Scope
This standard specifies the method for measuring the dielectric loss factor at the test temperature of the liquid insulating material, the relative permittivity and dc resistivity.
This standard is not used as a reference test liquid, but also applies to the operation of transformers, cables and other electricians set
Preparation of liquid. However, this standard applies only to single-phase liquid, and can be used to simplify the method described in Appendix C when measured as a routine
method.
For non-insulated liquid hydrocarbons, it requires the use of other cleaning methods.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 1409-2006 solid insulating materials at power, audio, high-frequency (including meter wavelengths included) of the permittivity and dielectric loss due to
Number recommended method (IEC 60250. 1969, MOD)
GB/T 1410-2006 solid insulating material volume resistivity and surface resistivity test methods (IEC 60093. 1980, IDT)
GB/T 21216-2007 insulating liquid measuring conductance and capacitance - Test methods for determining dielectric loss factor (IEC 61620.1998,
IDT)
IEC 60475 method for sampling liquid dielectrics
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
The relative permittivity of the insulating material is filled with all the insulating material surrounding a capacitor between the two electrodes and two electrodes having a capacitance
In a vacuum electric capacity ratio of the amount of C0 Cx similar electrode structure.
The air electrode is used in place of the capacitance Ca C0, for the measurement of relative permittivity with sufficient accuracy.
3.2
Insulation material dielectric loss factor (tanδ) is the loss tangent of the angle.
When the capacitor dielectric insulating material composed of only one loss phase angle refers to the applied voltage and the resulting current between
Deviates from π radian/2.
Note. The actual applications, tanδ measured value is less than 0.005, tanδ and power factor (PF) is substantially the same. Available a simple formula for converting the two into
Line conversion. Power factor is the relationship between the loss sine of the angle, power factor and dielectric loss factor can be expressed among the following formula.
PF = tanδ
1+ (tanδ) Sang 2
(1)
GB/T 5654-2007/IEC 60247.2004
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5654-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 5654-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5654-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5654-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5654-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5654-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|