US$274.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5332-2007: Method of test for ignition temperature of flammable liquids and gases Status: Valid GB/T 5332: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 5332-2007 | English | 274 |
Add to Cart
|
3 days [Need to translate]
|
Method of test for ignition temperature of flammable liquids and gases
| Valid |
GB/T 5332-2007
|
| GB/T 5332-1985 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Method of test for ignition temperature of flammable liquids and gases
| Obsolete |
GB/T 5332-1985
|
PDF similar to GB/T 5332-2007
Basic data | Standard ID | GB/T 5332-2007 (GB/T5332-2007) | | Description (Translated English) | Method of test for ignition temperature of flammable liquids and gases | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | C80 | | Classification of International Standard | 75.160 | | Word Count Estimation | 14,170 | | Date of Issue | 2007-07-02 | | Date of Implementation | 2008-01-01 | | Older Standard (superseded by this standard) | GB/T 5332-1985 | | Adopted Standard | IEC 60079-4-1975, IDT | | Regulation (derived from) | National Standard Announcement 2007 No.6 (Total No.106) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the determination of the pure chemical vapors of flammable liquids and gases ignition temperature (auto-ignition temperature) in air at atmospheric pressure. |
GB/T 5332-2007: Method of test for ignition temperature of flammable liquids and gases---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Method of test for ignition temperature of flammable liquids and gases
ICS 75.160
C80
National Standards of People's Republic of China
GB/T 5332-2007/IEC 60079-4. 1975
Replacing GB/T 5332-1985
Temperature Test Method for ignition of flammable liquids and gases
(IEC 60079-4. 1975, Electricalapparatusforexplosivegasatmospheres-
Part 4. Methodoftestforignitiontemperature, IDT)
Posted 2007-07-02
2008-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard is identical with IEC 60079-4. 1975 "explosive gas atmospheres Electrical Equipment Part 4 square test for ignition temperature
Law "second edition (in English and/or French), including its amendments IEC 60079-4-Amd1.1995.
This standard is equivalent translation IEC 60079-4. 1975.
For ease of use, this standard made the following editorial changes.
a) "this International Standard" be replaced by "this standard";
b) use a decimal point instead of a decimal comma ",". ",";
c) Remove the preface to the international standards;
d) Remove the suspension of paragraph 4;
e) increased 4.2 tables in table number, table name;
f) increased 4.4.1 and 4.4.2 of the section heading;
g) increased 5.1 bar title;
h) of the content to 5.2 5.2.1.
This standard replaces GB/T 5332-1985 "Test method for temperature ignition of flammable liquids and gases."
This standard and GB/T 5332-1985 compared to the major differences are as follows.
--- According to IEC 60079-4.1995 "Test Methods for repair orders ignition temperature 1" in Appendix A to asbestos insulation materials;
--- In Appendix A, adding another furnace (Furnace # 2) and the corresponding description of FIG.
Appendix A of this standard is an informative annex.
Please note that some of the content of this standard may involve patents. The standard release mechanism should not bear the responsibility to identify these patents.
The standard proposed by the People's Republic of China Ministry of Public Security.
This standard by the National Standardization Technical Committee on Fire First Technical Committee (SAC/TC113/SC1) centralized.
This standard was drafted. Tianjin Fire Research Institute of Ministry of Public Security.
The main drafters of this standard. Li Jin, Wang Gang, Zhang net, Zhang Xin, Sun incense, fruit Chunsheng, BIMONTHLY Wang Jie.
This standard replaces the standards previously issued as follows.
--- GB/T 5332-1985.
GB/T 5332-2007/IEC 60079-4. 1975
Temperature Test Method for ignition of flammable liquids and gases
1 Scope
This standard specifies the method for determination of chemical purity flammable liquid and vapor gas ignition temperature (self-ignition temperature) atmospheric pressure air.
2 Terms and definitions
The following terms and definitions apply to this standard.
2.1
According to the method specified in this standard test, the lowest temperature when ignition occurs.
2.2
Flammable liquids or gases in the test of the flask were heated, the occurrence of visible flame and/or explosive chemical reaction, this reaction
Delay time of less than 5min.
2.3
Instantaneous sample is completely injected into the flask to the time required for ignition occurs.
3 Test Overview
After exposure to a volume of 200mL conical flask was heated to a certain temperature, the flammable liquid or gas sample injection amount of the cone
Shaped flask, the flask in the dark room and observed whether ignition occurs. By using different temperatures and repeat the test sample amount, the ignition occurs
The lowest temperature of the flask as the sample in air at atmospheric pressure ignition temperature.
4 test device
4.1 Test flask (flask)
Use a volume of 200mL Erlenmeyer flask made of borosilicate glass. Test and final test shall be set for each sample
Use chemically cleaned by clean flask.
When the ignition temperature of the sample exceeds a borosilicate glass flask or a softening point of the sample flasks chemical corrosion, can be quartz flask
Or a metal flask, an acknowledgment in the test report.
4.2 Furnace
The flask was heated uniformly using a heating furnace. It gives the example of furnace suitable for this purpose in Appendix A.
When tested in accordance with this standard test procedure, if the measured substances in Table 1 in the ignition temperature of the error range given in Chapter 7
The, the flask experiment can be considered to be uniformly heated, the temperature selected measurement location is suitable. Purity used test specimens shall not
Less than 99.9%.
Table 1 furnace ignition temperature of the material verification
Combustible ignition temperature/℃
N-heptane
Ethylene
GB/T 5332-2007/IEC 60079-4. 1975
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5332-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 5332-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5332-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5332-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5332-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5332-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|