Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 4: Continuous syringe injection method
| Valid |
GB/T 5275.4-2014
|
PDF similar to GB/T 5275.4-2014
Basic data Standard ID | GB/T 5275.4-2014 (GB/T5275.4-2014) | Description (Translated English) | Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 4: Continuous syringe injection method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G86 | Classification of International Standard | 71.040.40 | Word Count Estimation | 17,171 | Date of Issue | 7/8/2014 | Date of Implementation | 12/1/2014 | Quoted Standard | ISO 6143; ISO 6145-1 | Adopted Standard | ISO 6145-4-2004, IDT | Regulation (derived from) | 2014 National Standards Bulletin No. 18 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the syringe to continuously inject gas balance calibration component gas mixture thereby continuously preparing method comprising two or more components from a purely calibration gas or gas mixture through the other. |
GB/T 5275.4-2014: Gas analysis -- Preparation of calibration gas mixtures using dynamic volumetric methods -- Part 4: Continuous syringe injection method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 4. Continuous syringe injection method
ICS 71.040.40
G86
National Standards of People's Republic of China
Gas analysis prepared dynamic volume Method
Calibration gas mixtures
Part 4. Continuous injection method
volumetricmethods-Part 4. Continuoussyringeinjectionmethod
(ISO 6145-4.2004, IDT)
Issued on. 2014-07-08
2014-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 5275 "gas analysis dynamic volume Preparation of calibration gas mixtures" is divided into the following sections.
--- Part 1. calibration method;
--- Part 2. positive displacement pump;
--- Part 4. continuous injection;
--- Part 5. Capillary calibration devices;
--- Part 6. Critical orifices;
--- Part 7. Thermal mass flow controller;
--- Part 8. Diffusion method;
--- Part 9. Saturation method;
--- Part 10. Permeation;
--- Part 11. Electrochemical method occurs.
This section GB/T 45275 Part of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 6145-4.2004 "gas analysis dynamic volume Preparation of calibration gas mixtures 4th
Part I. Continuous injection method. "
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 10628-2008 gas analysis calibration gas mixture composition measurements and comparison test (ISO 6143.2001,
IDT);
--- GB/T 5275.1-2014 gas analysis equipment dynamic volume Method of calibration gas mixtures - Part 1. calibration method
(ISO 6145-1.2003, IDT).
This part is proposed by the China Petroleum and Chemical Industry Association.
This part of the National Gas Standardization Technical Committee (SAC/TC206) centralized.
This section drafted by. China Institute of Metrology, Southwest Chemical Industry Research and Design Institute Co., Ltd., Beijing helium gas industry has divided the North Cape
Limited, the Ministry of Environmental Protection Institute of the standard sample.
The main drafters of this section. Zhouze Yi, Jane red, Chen Yali, Zhaojun Xiu, Tian.
Gas analysis prepared dynamic volume Method
Calibration gas mixtures
Part 4. Continuous injection method
1 Scope
GB/T 5275 provisions of this section from a pure gas or gas mixture through a syringe to the other balance calibration gas is continuously injected components, from
Continuously prepared containing two or more components of the gas mixture with the calibration methods.
Use premixed gas instead of pure gas (see Appendix A) can be prepared in a mixed gas volume fraction low. Determine the volume fraction of the volume flow,
By a single flow of gas is calculated, it may also be an appropriate method of independent measurements given in ISO 6145-1.
Advantage of continuous injection law can be prepared continuously large number of mixed gas, and as long as the appropriate number of syringes or single syringe
Known multi-component gas mixture containing the gas can be as prepared as easily as binary mixtures prepared multi-component gas mixture. The method may further
By a few steps and easily increase calibration components in a mixed gas volume fraction. Therefore, it can be used to evaluate a gas analyzer
Some other features, such as the limit of detection, blind and accuracy. Binary mixed gas prepared by the method (coverage factor k = 2) relative expanded
Uncertainty of 5%, the scope of 10-5 to 10-2 (volume fraction).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 6143 Gas analysis calibration gas mixture composition measurements and check Comparative Law (Gasanalysis-Comparison
methodsfordeterminingandcheckingthecompositionofcalibrationgasmixtures)
ISO 6145-1 Gas analysis dynamic volume Preparation of calibration gas mixtures - Part 1. calibration method (Gasanalysis-
Preparationofcalibrationgasmixturesusingdynamicvolumetricmethods-Part 1. Methodsofcali-
bration)
Principle 3
Component calibration gas or liquid phase by syringe into the capillaries and then into the gas stream balance, the capillary can be a needle injection device
Vials, syringes, pistons driven by a suitable variable speed motor.
A component in the gas mixed with the balance gas volume fraction φA B by the formula (1) is given by.
φA = qA/(qA qB) (1)
Where.
qA --- calibration component A volume flow;
Gas volume flow qB --- balance of B.
If the calibration component is injected as a liquid, the gas flow rate after the volatile by the formula (2) is given by.
qA = (qA, l × ρA, l)/ρA, g (2)
Where.
qA, l --- injection volume flow rate of liquid, which is the same unit of measure qA;
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5275.4-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 5275.4-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5275.4-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5275.4-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|