US$154.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5013.7-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables Status: Valid GB/T 5013.7: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 5013.7-2008 | English | 154 |
Add to Cart
|
3 days [Need to translate]
|
Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables
| Valid |
GB/T 5013.7-2008
|
GB 5013.7-1997 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
Rubber insulated cables of rated voltages up to and including 450/750V. Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables
| Obsolete |
GB 5013.7-1997
|
PDF similar to GB/T 5013.7-2008
Basic data Standard ID | GB/T 5013.7-2008 (GB/T5013.7-2008) | Description (Translated English) | Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K13 | Classification of International Standard | 29.060.20 | Word Count Estimation | 8,810 | Date of Issue | 2008-01-22 | Date of Implementation | 2008-09-01 | Older Standard (superseded by this standard) | GB 5013.7-1997 | Quoted Standard | GB/T 2951.1-1997; GB/T 2951.2-1997; GB/T 2951.5-1997; GB/T 2951.6-1997; GB/T 3956; GB/T 5013.1-2008; GB/T 5013.2-2008 | Adopted Standard | IEC 60245-7-1994, IDT | Regulation (derived from) | Announcement of Newly Approved National Standards No. 2, 2008 (No. 115 overall) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the rated voltage 450/750V ethylene vinyl acetate rubber insulated cables technical requirements. Each cable shall comply with GB/T 5013. 1 requirements and the special requirements of this section. |
GB/T 5013.7-2008: Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 7: Heat resistant ethylene-vinyl acetate rubber insulated cables ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Rubber insulated cables of rated voltages up to and including 450/750 V. Part 7. Heat resistant ethylene-vinyl acetate rubber insulated cables
ICS 29.060.20
K13
National Standards of People's Republic of China
GB/T 5013.7-2008/IEC 60245-7.1994
Replacing GB 5013.7-1997
Rated voltage 450/750 and below Vp
Rubber insulated cables
Part 7. Heat resistant ethylene - vinyl acetate
Rubber insulated cables
(IEC 60245-7.1994, IDT)
Posted 2008-09-01 2008-01-22 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections.
--- Part 1. General requirements;
--- Part 2. Test methods;
--- Part 3. Heat resistant silicone rubber insulated cables;
--- Part 4. Cords and flexible cables;
--- Part 5. Lift cables;
--- Part 6. Arc welding cables;
--- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables;
--- Part 8. Cords.
This section GB/T 5013 Part 7. This section identical with IEC 60245-7.1994 "rated voltage 450/750V and with
Under rubber insulated cables Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables "(in English) and its amendments Amendment1.
1997 (in English).
For ease of use, GB/T 5013 made this part of the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Delete international standards foreword.
This part of IEC original 2.3.4 and 3.3.4 corresponding editorial errors were corrected.
This section from the implementation date instead of GB 5013.7-1997.
This section of the main changes compared to GB 5013.7-1997 are as follows.
--- Table 1 and Table 3, increased the average outer diameter of the lower limit, the average outer diameter of the cap and modify the value.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee of wire and cable.
This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.
Participated in the drafting of this section. Jiangsu Shangshang Cable Group, Kunming Cable Co., Ltd., Qingdao Hanlan Group Co., Ltd., Hainan
Yang Cable Co., Ltd., Tianjin Jinshan Electric Wire & Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd.
The main drafters of this section. gold righteousness, talk Jianwei, He Wenjun, Zhang Liming, Tan Jinfeng, Zheng Guojun, Xia Yafang.
This part of the standard replaces the previous editions as. GB 5013.7-1997.
GB/T 5013.7-2008/IEC 60245-7.1994
Rated voltage 450/750 and below Vp
Rubber insulated cables
Part 7. Heat resistant ethylene - vinyl acetate
Rubber insulated cables
1 Overview
1.1 Scope
This section GB/T 5013 gives a rated voltage of 450/750V and below, ethylene - vinyl acetate rubber insulated cable technology
Claim.
Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations.
1.2 Normative references
The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick
Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993)
GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot
Aging methods (idt IEC 60811-1-2. 1985)
GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side
Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986)
GB/T 2951.6-1997 cable insulation and sheathing materials test methods - Part 3. Test method specific to PVC compounds
Act 1. temperature pressure test - resistance to cracking (idt IEC 60811-3-1. 1985)
GB/T 3956 cable conductor (GB/T 3956-1997, idt IEC 60228. 1978)
GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC
60245-1.2003, IDT)
GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC
60245-2.1998, IDT)
2 maximum conductor temperature of 110 ℃ heat-resistant ethylene - vinyl acetate rubber or other equivalent synthetic elastomer insulated, single-core, non-sheathed
750 Vp cable
2.1 Model
Solid or stranded conductors. 60245IEC 04 (YYY);
Flexible conductor. 60245IEC 05 (YRYY).
2.2 Rated voltage
450/750V.
2.3 Structure
2.3.1 Conductor
Number of cores. a core.
Conductor shall comply with GB/T 3956 requirements.
GB/T 5013.7-2008/IEC 60245-7.1994
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5013.7-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 5013.7-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5013.7-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5013.7-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5013.7-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5013.7-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|