US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 4333.4-2007: Ferrosilicon -- Determination of aluminium content -- The chrome azurol S spectrophotometric method, the EDTA titrimetric method and the flame atomic absorption spectrometric method Status: Valid GB/T 4333.4: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 4333.4-2007 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Ferrosilicon -- Determination of aluminium content -- The chrome azurol S spectrophotometric method, the EDTA titrimetric method and the flame atomic absorption spectrometric method
| Valid |
GB/T 4333.4-2007
|
| GB/T 4333.4-1988 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods for chemical analysis of ferrosilicon--The chromazurol S photometric method for the determination of aluminium content
| Obsolete |
GB/T 4333.4-1988
|
| GB/T 4333.4-1984 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Methods for chemical analysis of ferrosilicon--The chromazurol S photometric method for the determination of aluminium content
| Obsolete |
GB/T 4333.4-1984
|
PDF similar to GB/T 4333.4-2007
Basic data | Standard ID | GB/T 4333.4-2007 (GB/T4333.4-2007) | | Description (Translated English) | Ferrosilicon -- Determination of aluminium content -- The chrome azurol S spectrophotometric method, the EDTA titrimetric method and the flame atomic absorption spectrometric method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | H11 | | Classification of International Standard | 77.100 | | Word Count Estimation | 12,193 | | Date of Issue | 2007-09-11 | | Date of Implementation | 2008-02-01 | | Older Standard (superseded by this standard) | GB/T 4333.4-1988; GB/T 4333.5-1997; GB/T 4333.9-1988 | | Quoted Standard | GB/T 4010 | | Regulation (derived from) | China National Standard Approval Announcement2007 No.11 (Total No.111) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the determination of ferrosilicon aluminum content-Chromazurol S spectrophotometry, EDTA titration and flame atomic absorption spectrometry. Warning-Use this section personnel should experience regular laboratory work. This section does not indicate that all possible safety problems. Users are responsible for taking appropriate safety and health practices and to ensure compliance with the relevant provisions of the conditions of the country. This section applies to the determination of aluminum content in ferrosilicon. Chromazurol S spectrophotometric measurement range (mass fraction): 0. 10% ~ 0. 60%, EDTA titration range (mass fraction): 0. 60%-5. 00%, Flame Atomic Absorption Spectrometry range (mass fraction) |
GB/T 4333.4-2007: Ferrosilicon -- Determination of aluminium content -- The chrome azurol S spectrophotometric method, the EDTA titrimetric method and the flame atomic absorption spectrometric method
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Ferrosilicon. Determination of aluminium content. The chromazurol S spectrophotometric method, the EDTA titrimetric method and the flame atomic absorption spectrometric method
ICS 77.100
H11
National Standards of People's Republic of China
Replacing GB/T 4333.4-1988, GB/T 4333.5-1997, GB/T 4333.9-1988
Ferrosilicon aluminum content Azure S spectrophotometric determination of chromium
Spectrophotometry, EDTA titration and
Flame Atomic Absorption Spectrometry
Posted 2007-09-11
2008-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
GB/T 4333 This section includes the three measuring Chromium Azure S Spectrophotometry, EDTA titration and flame atomic absorption spectrometry
Analysis ferrosilicon aluminum content. This Part replaces GB/T 4333.4-1988 "Methods for chemical analysis of ferrosilicon chrome azure S Spetrophotometry
Given the amount of aluminum ", GB/T 4333.5-1997" Determination of aluminum content "and GB/T 4333.9-1988 Methods for chemical analysis of ferrosilicon EDTA volumetric method
"Methods for chemical analysis of ferrosilicon flame atomic absorption spectrometric method for the determination of aluminum content."
This portion of the GB/T 4333.4-1988, GB/T 4333.5-1997 and GB/T 4333.9-1988 comparison, in addition to the allowable difference portion
Edit points, mainly on the GB/T 4333.5-1997 made the following technical modifications.
--- The amount of the sample by the 0.5000g, 0.2500g, 0.1500g adjusted to 0.80g and 0.50g;
Zinc Standard Solution --- titration using xylenol orange as indicator Cu-PAN instead of copper as an indicator of the standard titration solution
system;
--- Using sodium carbonate - boric acid flux instead of sodium bisulfate acid insoluble residue decomposition;
--- Using hydrochloric acid - hexamethylenetetramine and alkali secondary separation interference, instead of methyl isobutyl ketone extraction of iron, aluminum and copper precipitate ammonium benzoate
Ferron separation separation of titanium;
--- Using hydrochloric acid - hexamethylenetetramine instead of acetic acid - ammonium acetate buffer solution as the titration system.
This part is proposed by the China Iron and Steel Association.
This section is under the jurisdiction of Metallurgical Industry Information Standards Institute.
This standard was drafted. Sichuan Investment Emei Ferroalloy (Group) Co., Ltd.
The main drafters of this section. Tang Hua Ying, Wu Cuiping, Xuexiu Ping, Fang Yan.
This part of the standard replaces the previous editions are.
--- GB/T 4333.4-1984, GB/T 4333.4-1988;
--- GB/T 4333.5-1984, GB/T 4333.5-1997;
--- GB/T 4333.9-1988.
Ferrosilicon aluminum content Azure S spectrophotometric determination of chromium
Spectrophotometry, EDTA titration and
Flame Atomic Absorption Spectrometry
Warning --- Use this section shall be a person experiences regular laboratory work. This section does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
GB/T 4333 provisions of this part of the chromium azure S spectrophotometric determination of silicon EDTA titration and flame atomic absorption spectrometry
Iron aluminum content.
This section applies to the determination of ferrosilicon aluminum content. Chromium Azure S Spectrophotometry range (mass fraction). 0.10% to 0.60%;
EDTA titration range (mass fraction). 0.60% - 5.00%; flame atomic absorption spectrometry range (mass fraction).
0.05% to 5.00%.
2 Normative references
The following documents contain provisions which, through reference to GB/T 4333 this section, constitute provisions of this part. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 4010 alloy chemical analysis and preparation of samples
3 Method One. Chromium Azure S Spectrophotometry
3.1 Principle
Sample with nitric acid, hydrofluoric acid dissolution, perchloric acid smoke, then dilute hydrochloric acid medium to precipitate cupferron iron, vanadium, titanium and other elements. again
At a pH (5.8 ± 0.4) in hydrochloric acid solution with hexamethylenetetramine buffer solution, aluminum and chrome azure S purple envelope and was formed,
Spectrophotometer 550nm wavelength measured absorbance.
3.2 Reagents and materials
Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled water or its equivalent purity water.
3.2.1 sodium bisulfate, solid.
3.2.2 nitrate, ρ1.42g/mL.
3.2.3 perchloric acid, ρ1.67g/mL.
3.2.4 hydrofluoric acid, ρ1.15g/mL.
3.2.5 hydrochloric acid, ρ1.19g/mL.
3.2.6 hydrochloric acid, 1 + 9.
3.2.7 hydrochloric acid, 20 + 1.
3.2.8 hydrochloric acid, 60 + 1.
3.2.9 hydrochloric acid, 99 + 1.
3.2.10 ammonia, 1 + 9, stored in a plastic bottle.
3.2.11 ammonium fluoride solution, 20g/L. Stored in plastic bottles.
3.2.12 hexamethylenetetramine solution, 200g/L. Weigh 200g of hexamethylenetetramine dissolved in water, dilute to 1L, stored in plastic bottles.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 4333.4-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 4333.4-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 4333.4-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 4333.4-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 4333.4-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4333.4-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|