|
US$694.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 42064-2022: Equipment for general lighting purposes - Flicker characteristics - Test method applying light flicker meter Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 42064-2022 | English | 694 |
Add to Cart
|
6 days [Need to translate]
|
Equipment for general lighting purposes - Flicker characteristics - Test method applying light flicker meter
| Valid |
GB/T 42064-2022
|
PDF similar to GB/T 42064-2022
Basic data | Standard ID | GB/T 42064-2022 (GB/T42064-2022) | | Description (Translated English) | Equipment for general lighting purposes - Flicker characteristics - Test method applying light flicker meter | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K71 | | Classification of International Standard | 33.100 | | Word Count Estimation | 38,343 | | Date of Issue | 2022-10-12 | | Date of Implementation | 2023-05-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 42064-2022: Equipment for general lighting purposes - Flicker characteristics - Test method applying light flicker meter ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Equipment for general lighting purposes - Flicker characteristics - Test method applying light flickermeter
ICS 33.100
CCSK71
National Standards of People's Republic of China
General lighting equipment
Flicker characteristic light scintillation meter test method
Released on 2022-10-12
2023-05-01 implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
table of contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms, Definitions, Abbreviations and Symbols 2
4 General 4
5 Light Scintillation Meter 5
6 Voltage fluctuation interference signal 5
7 Test setup and equipment 8
8 Verification procedure 11
9 Test procedure 13
10 Test conditions 16
11 Evaluation of test results 16
12 Test report 16
Appendix A (Informative) Optical Scintillation Meter Specifications 18
Appendix B (Informative) Uncertainty Discussion 22
Appendix C (Informative) Lighting Equipment Test Results Example 25
Appendix D (informative) PLMst test guidelines based on test type 31
Reference 32
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
This document is equivalent to IEC TR61547-1.2020 "Electromagnetic Compatibility Immunity Requirements for General Lighting Equipment Part 1.Objective
Test Method for Optical Scintillation Meter and Voltage Fluctuation Immunity", the file type has been adjusted from IEC technical report to the national standard of our country.
The following minimal editorial changes have been made to this document.
--- Modified the name of the standard;
---Adjusted the list of normative references in Chapter 2 according to the specific reference method in the text;
--- TLA is added to the abbreviation;
--- P1t is added in the symbol.
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by China National Light Industry Council.
This document is under the jurisdiction of the National Standardization Technical Committee of Lighting Appliances (SAC/TC224).
This document is mainly drafted by. Hengdian Group Debang Lighting Co., Ltd., Beijing Electric Light Source Research Institute Co., Ltd., National Electric Light Source
Quality Supervision and Inspection Center (Beijing), Xiamen Tongshida Lighting Co., Ltd., Zhangzhou Lidaxin Photoelectric Technology Co., Ltd., Ningbo Lange Lighting
Electric Co., Ltd., Changzhou Tianzheng Industrial Development Co., Ltd.
The main drafters of this document. Nie Lixun, Bao Linjie, Wang Chong, Gao Tao, Pei Lihua, Ni Wei, Zhang Junbin, Yang Jie, Zhang Chonghao, Yang Qingfeng.
General lighting equipment
Flicker characteristic light scintillation meter test method
1 Scope
This document describes an objective light scintillation meter that can be used for the following purposes.
---Measure the inherent performance of lighting equipment without introducing voltage fluctuations related to illuminance flicker. During this measurement, provide lighting equipment
Provide a stable power supply.
--- Test the immunity of lighting equipment to (unintentional) voltage fluctuations applied to the AC power supply in terms of illuminance flicker; here
During the test, a specified set of voltage fluctuations is applied to the AC mains and the immunity of the lighting equipment to disturbances is determined.
In addition to the above two purposes, the immunity of lighting equipment can also be tested under the AC power supply with predetermined voltage fluctuations, such as from
The signal is transmitted from the power supply. However, this document does not define it in further detail.
Note 1.IEC 61000-4-13.2015[24] provides guidance on the test level and frequency of interference power transmission signals.
This document establishes a common and objective test reference to evaluate the performance of lighting equipment in terms of illuminance flicker. This test does not
Consider temporal changes in the color of light (flickering of colors).
This method applies to lighting equipment covered by IEC TC34, such as lamps and luminaires intended to be connected to the low-voltage network system. alone
Independent accessories, such as control gear, can be tested with representative light sources.
The objective optical scintillation meter and voltage fluctuation immunity method described in this document is based on the standards of IEC 61000-3-3 Voltage fluctuation limits and
IEC 61000-4-15 Standard for scintillation meters.
The objective optical scintillation meter described in this document is suitable for objectively evaluating the flicker of lighting equipment powered by various power sources, such as AC mains, DC
mains, battery or via external dimming. The specific voltage fluctuation immunity test method described in this document is applicable to the rated voltage
120VAC and rated voltage 230VAC, 50Hz and 60Hz lighting equipment.
Note 2.The principle of the above method can be used for other nominal voltage and frequency values.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
IEC 61000-3-3 Electromagnetic Compatibility Part 3-3.Limits for equipment with rated current ≤ 16A per phase and unconditional access in public
connection]
Note. GB/T 17625.2-2007 electromagnetic compatibility limit is for the equipment with rated current ≤ 16A per phase and unconditional access in the public low-voltage power supply system
Limits of resulting voltage changes, voltage fluctuations and flicker (IEC 61000-3-3.2005, IDT)
IEC 61000-4-15 Electromagnetic Compatibility Part 4-15.Test and Measurement Techniques Scintillation Meter Function and Design Specifications [Electro-
|