US$419.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 41629.2-2022: Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV) - Part 2: Long AC submarine cables Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 41629.2-2022 | English | 419 |
Add to Cart
|
4 days [Need to translate]
|
Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV) - Part 2: Long AC submarine cables
| Valid |
GB/T 41629.2-2022
|
PDF similar to GB/T 41629.2-2022
Basic data Standard ID | GB/T 41629.2-2022 (GB/T41629.2-2022) | Description (Translated English) | Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV) - Part 2: Long AC submarine cables | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K13 | Word Count Estimation | 22,213 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 41629.2-2022: Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV) - Part 2: Long AC submarine cables ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Long AC submarine cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500 kV(Um=550 kV) - Part 2.Long AC submarine cables
ICS 29.060.20
CCSK13
National Standards of People's Republic of China
Rated voltage 500kV (Um=550kV) cross-linking
Polyethylene insulated long-length AC submarine cables and accessories
Part 2.Large length AC submarine cables
Published on 2022-07-11
2023-02-01 Implementation
State Administration for Market Regulation
Released by the National Standardization Administration
directory
Preface III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Use feature 2
5 Product code, model, specification and product representation 2
6 Cable material and construction 4
7 Finished cable marking 9
8 Finished cable requirements9
9 Acceptance Rules 11
10 Shipping and Storage 12
11 Test after laying 12
Appendix A (Informative) Properties of Cross-Linked Polyethylene Insulating Materials 13
Appendix B (Informative) Properties of Semiconductive Shielding Materials 14
Appendix C (Informative) Properties of Semiconductive Sheathing Compounds and Wrapping Tapes 15
Reference 16
Table 1 Types and names of submarine cables3
Table 2 Specifications of submarine cables3
Table 3 Nominal thickness of insulating layer4
Table 4 Nominal thickness of lead sleeve6
Table 5 Nominal thickness of inner sheath6
Table 6 Identification color code8
Table 7 Test Category and Code 9
Table 8 Routine test and sampling test items and requirements for finished cables9
Table 9 Type test items and requirements for finished cables 10
Table 10 Optical fiber unit test items and requirements 11
Table A.1 Properties of XLPE insulating material 13
Table B.1 Properties of semiconductive shielding materials 14
Table C.1 Properties of Semiconductive Sheath Materials and Tape 15
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
drafted.
This document is GB/T 41629 "rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cables and accessories
Part 2.GB/T 41629 has released the following parts.
--- Part 1.Test methods and requirements;
--- Part 2.Large-length AC submarine cables;
--- Part 3.Submarine cable accessories.
Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by China Electrical Equipment Industry Association.
This document is under the jurisdiction of the National Standardization Technical Committee of Wires and Cables (SAC/TC213).
This document is drafted by. China Electric Power Research Institute Co., Ltd., Shanghai Electric Cable Research Institute Co., Ltd., Shanghai State Cable Testing Co., Ltd.
Co., Ltd., Zhongtian Technology Submarine Cable Co., Ltd., State Grid Zhejiang Electric Power Co., Ltd. Electric Power Research Institute, Ningbo Dongfang Cable Co., Ltd.
Co., Ltd., Jiangsu Hengtong High Voltage Submarine Cable Co., Ltd., Qingdao Han Cable Co., Ltd., AVIC Baosheng Offshore Engineering Cable Co., Ltd., Futong Living
Electric Submarine Cable Co., Ltd.
The main drafters of this document. Zhao Jiankang, Xu Xiaofeng, Li Chuang, Hu Ming, Wang Shaohua, Zheng Lin, Pan Wenlin, Duan Weixi, Zhang Huiluo, Zhou Houqiang,
Zhang Zhenpeng, Xu Mingzhong, Shi Nannan, Sun Jiansheng, Fan Yujun, Gu Xiao, Hu Liexiang, Li Te.
Introduction
Submarine cables are widely used in offshore wind power transmission, island power supply, and offshore platform power supply and distribution. Compared with onshore cables, submarine power
The cable has the characteristics of complex product structure, high protection requirements, and special grounding methods. GB/T 41629 is rated voltage 500kV submarine cable
Product standards for submarine cables and accessory systems, including the naming rules, test methods, technical requirements, etc. of submarine cables and accessory systems, consisting of the following 3
composed of parts.
--- Part 1.Test methods and requirements. The purpose is to unify the test and technology of the rated voltage 500kV submarine cable and accessory system.
technical requirements.
--- Part 2.Large-length AC submarine cables. The purpose is to unify the structural parameters and basic parameters of the rated voltage 500kV submarine cable.
performance requirements.
--- Part 3.Submarine cable accessories. The purpose is to unify the structural parameters and basics of the rated voltage 500kV submarine cable accessories
can request.
Rated voltage 500kV (Um=550kV) cross-linking
Polyethylene insulated long-length AC submarine cables and accessories
Part 2.Large length AC submarine cables
1 Scope
This document specifies the rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cable (the following submarine electricity
Cable refers to the type, material, technical requirements, test, acceptance rules, shipment, storage and transportation of AC submarine cables).
This document is applicable to the XLPE insulation with rated voltage of 500kV (Um=550kV) used under subsea laying and operating conditions.
Length AC submarine cable (including fiber optic composite).
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document.
GB/T 2951.11-2008 General test methods for insulating and sheathing materials of electrical and optical cables - Part 11.General test methods
Thickness and Outline Dimensions Measurement Mechanical Properties Test
GB/T 3956-2008 Conductor of cables
GB/T 6995.1 Wire and Cable Identification Marking Method Part 1.General Provisions
GB/T 6995.2 Wire and Cable Identification Marking Method Part 2.Standard Colors
GB/T 9771 (all parts) single-mode optical fiber for communication
GB/T 12357 (all parts) Multimode optical fibers for communication
GB/T 15972.40-2008 Specification for test methods for optical fibers - Part 40.Measurement methods and tests for transmission and optical properties
Program decay
GB/T 15972.42-2021 Specification for test methods for optical fibers - Part 42.Measurement methods and test procedures for transmission characteristics Wavelength
Dispersion
GB/T 41629.1-2022 Rated voltage 500kV (Um=550kV) XLPE insulated long-length AC submarine cables and
Annex Part 1.Test Methods and Requirements
JB/T 8996 Guidelines for selection of high voltage cables
3 Terms and Definitions
The terms and definitions defined in GB/T 41629.1-2022 and the following apply to this document.
3.1
approximatevalue
A value that is neither guaranteed nor checked.
Note. Approximate values are usually used in the calculation of other dimension values.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 41629.2-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 41629.2-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 41629.2-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 41629.2-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|