GB/T 41577-2022: Operational intervention levels for nuclear power plant emergencies
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 41577-2022English349 Add to Cart 4 days [Need to translate] Operational intervention levels for nuclear power plant emergencies Valid GB/T 41577-2022

PDF similar to GB/T 41577-2022


Standard similar to GB/T 41577-2022

GB 39220   EJ/T 307   GB 27742   GB/T 41580   GB/T 41579   

Basic data

Standard ID GB/T 41577-2022 (GB/T41577-2022)
Description (Translated English) Operational intervention levels for nuclear power plant emergencies
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F70
Word Count Estimation 17,160
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 41577-2022: Operational intervention levels for nuclear power plant emergencies

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Operational intervention levels for nuclear power plant emergencies ICS 27.120 CCSF70 National Standards of People's Republic of China Intervention level of emergency operation of nuclear power plant Published on 2022-07-11 2023-02-01 Implementation State Administration for Market Regulation Released by the National Standardization Administration directory Preface I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Operational Intervention Level Application Purpose 2 5 Establishment of Operational Intervention Levels 2 5.1 Type 2 of operational intervention levels 5.2 Default values for operational intervention levels3 5.3 Description of default values for operational intervention levels 3 5.3.1 Description of OIL1 3 5.3.2 Description of OIL2 4 5.3.3 Description of OIL3 4 5.3.4 Description of OIL4 4 5.3.5 Description of OIL5 5 5.3.6 Description of OIL6 5 5.3.7 Description of OIL7 5 5.3.8 Description of OIL8 5 5.3.9 Description of OIL9 5 5.4 Determination of initial values for operational intervention levels 6 6 Operational Intervention Level Correction 6 6.1 General requirements6 6.2 OIL1 and OIL2 corrections 6 6.3 OIL4 Amendment 7 6.4 OIL6 and OIL7 corrections 7 6.5 OIL8 and OIL9 Correction 8 Appendix A (Normative) Dose Action Levels for Acute Exposure9 Appendix B (normative) Generic optimized intervention levels and action levels in emergency exposure situations10 Appendix C (Informative) Inhaled dose rate conversion factor11 Appendix D (informative) Deposition dose and deposition dose rate conversion factor 12 Reference 14

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents" drafted. Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed and managed by the National Nuclear Energy Standardization Technical Committee (SAC/TC58). This document was drafted by. China Institute of Radiation Protection, Fujian Fuqing Nuclear Power Co., Ltd., Institute of Nuclear Industry Standardization. The main drafters of this document. Xu Xiaoxiao, Zhang Jiangang, Wang Renze, Yang Yapeng, Feng Zongyang, Jin Li, Jia Linsheng, Dong Fangfang, Guo Jianxin, Li Yufang and Zheng Jijia. Intervention level of emergency operation of nuclear power plant

1 Scope

This document specifies the methodology for establishing and correcting operational intervention levels under reactor emergency conditions. This document applies to pressurized water reactors, other types of reactors can also be used for reference.

2 Normative references

The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document. GB 18871-2002 Basic standard for ionizing radiation protection and radiation source safety

3 Terms and Definitions

The following terms and definitions apply to this document. 3.1 interventionlevel The preventable dose level established for an emergency exposure situation or a continuous exposure situation. NOTE. When reaching this preventable dose level, consider taking appropriate protective or remedial actions. [Source. GB 18871-2002, J6.10, with modifications] 3.2 actionlevel In the case of continuous exposure or emergency exposure, the dose level or activity concentration level at which remedial action or protective action is taken into account. [Source. GB 18871-2002, J6.11, with modifications] 3.3 The value derived from the corresponding generic intervention level or generic action level. NOTE. Operational intervention levels are quantities that can be directly compared with instrumental measurements or laboratory analyses, such as ambient dose equivalents in radioactive plumes rate, radionuclide concentration, etc. 3.4 Preventable dose of averagedose The dose reduced by taking protective action, that is, the dose expected to be received if protective action is taken and the dose not taking protective action The difference between the doses expected to be received under the circumstances. [Source. GB 18871-2002, J6.9] 3.5 covert sheltering Emergency protection measures for personnel staying (or entering) indoors, closing doors, windows and ventilation systems.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 41577-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 41577-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 41577-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 41577-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.