|
US$669.00 ยท In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 41504-2022: Test method of burglar resistance for building external windows, doors and shutters Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 41504-2022 | English | 669 |
Add to Cart
|
5 days [Need to translate]
|
Test method of burglar resistance for building external windows, doors and shutters
| Valid |
GB/T 41504-2022
|
PDF similar to GB/T 41504-2022
Basic data | Standard ID | GB/T 41504-2022 (GB/T41504-2022) | | Description (Translated English) | Test method of burglar resistance for building external windows, doors and shutters | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | P32 | | Word Count Estimation | 34,338 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 41504-2022: Test method of burglar resistance for building external windows, doors and shutters ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of burglar resistance for building external windows, doors and shutters
ICS 91.060.50
CCSP32
National Standards of People's Republic of China
Doors, windows and shutters outside the building prevent abnormal opening
Performance testing method
shutters
Published on 2022-04-15
2022-11-01 Implementation
State Administration for Market Regulation
Released by the National Standardization Administration
directory
Preface I
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Grading and Judgment 2
5 Testing equipment and personnel 4
6 Specimen and installation 9
7 Detection 10
8 Test report 13
Appendix A (normative) Test method for damage resistance of glass panel 14
Appendix B (normative) Anti-static load performance detection point and position 20
Appendix C (normative) Impact resistance testing location 29
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
drafted.
Please note that some content of this document may be patented. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China.
This document is under the jurisdiction of the National Standardization Technical Committee for Building Curtain Walls and Doors and Windows (SAC/TC448).
This document is drafted by. China Academy of Building Research Co., Ltd., Guangdong Jianlang Hardware Products Co., Ltd., Sigiriya Obi
Window and Door Hardware (Sanhe) Co., Ltd., Jianyan Testing Group Co., Ltd., Hebei Orun Shunda Window Industry Co., Ltd., Xiluo Construction Technology (Guangdong)
Co., Ltd., Zhuhai Xingye Green Building Technology Co., Ltd., Guangdong Chuangao Curtain Wall Door and Window Engineering Co., Ltd., Botian (Shanghai) Hardware Co., Ltd.
Company, Guangdong Century Construction Group Co., Ltd., Shenzhen General Institute of Architectural Design and Research Co., Ltd., Henan Provincial Institute of Architectural Sciences Co., Ltd.
Company, Greentown Decoration Engineering Group Co., Ltd., Zhejiang Hongyi Construction Co., Ltd., Mingwei Technology Group Co., Ltd., Wangli Security Technology Co., Ltd.
Co., Ltd., Guangdong Kraton Curtain Wall Co., Ltd.
The main drafters of this document. Wang Hongtao, Shi Qing, Yan Qiang, Qiu Ming, Han Kun, Wang Liang, Wang Yaping, Jiao Changlong, Feng Tao, Cheng Yan, Yang Cuijuan,
Ye Baoxia, Huo Jianfeng, Ma Shiming, Chang Jianguo, Wang Xian, Jiang Xianlong, Liu Yongliang, Wang Yuebin, Feng Yingzhang, Liu Huitao, Wang Junyang, Liu Huihua, Shan Bo,
Sun Meifeng, Hu Naidong, Wang Ye, Hou Yuanyuan.
Doors, windows and shutters outside the building prevent abnormal opening
Performance testing method
1 Scope
This document specifies the classification, testing equipment and personnel, test pieces, installation, testing and
Report.
This document is applicable to the laboratory testing of the anti-abnormal opening performance of exterior doors, windows and shutters.
This document is not applicable to the detection of the connection between the test piece and the wall, and the damage to the test by technical means to open the lock cylinder or chemical corrosion.
the case where the item enters the non-intrusive side.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations
documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to
this document.
GB/T 3785.1 Electroacoustic Sound Level Meter Part 1.Specification
GB/T 5823 Terms of Building Doors and Windows
GB/T 6031-2017 Determination of hardness of vulcanized rubber or thermoplastic rubber (10IRHD~100IRHD)
GB/T 13304.1 Steel Classification Part 1.Classification by Chemical Composition
GB 15763.3-2009 Safety Glass for Construction Part 3.Laminated Glass
GB/T 38264 Classification and testing methods of impact resistance performance of building curtain walls
GA/T 73-2015 Mechanical anti-theft lock
JG/T 393-2012 Double-sided handle for building door and window hardware
3 Terms and Definitions
The terms and definitions defined in GB/T 5823 and the following apply to this document.
3.1
shutters
shutter doors and windows
A collective term for shutter doors and shutters.
Note. For the definition of shutters and shutters, see 3.4.7 and 4.4.5 in GB/T 5823-2008.
3.2
Anti-abnormal opening performance burglarresistance
The ability of doors, windows and shutters to resist entering the non-intrusive side through abnormal opening methods within the specified time.
Note. Abnormal opening refers to the opening of doors, windows and shutters by applying static loads, impact loads, and using specific tools to break down.
3.3
intrusion side attackside
During actual use, the side may be subject to abnormal opening.
Note. The other side of the invasive side is the non-invasive side. In practical engineering, there may be cases where both sides of the specimen are intrusion sides.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 41504-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 41504-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 41504-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 41504-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|