Polyethylene (PE), polypropylene (PP) and polystyrene (PS) resin -- Determination of peroxide value
| Valid |
GB/T 38286-2019
|
Standard ID | GB/T 38286-2019 (GB/T38286-2019) | Description (Translated English) | Polyethylene (PE), polypropylene (PP) and polystyrene (PS) resin -- Determination of peroxide value | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G31 | Classification of International Standard | 83.080.01 | Word Count Estimation | 6,666 | Date of Issue | 2019-12-10 | Date of Implementation | 2020-11-01 | Drafting Organization | China Certification and Inspection Group Ningbo Co., Ltd., Ningbo Customs of the People's Republic of China, Guangzhou Special Pressure Equipment Testing Research Institute, Zhonglan Chenguang Chengdu Testing Technology Co., Ltd., Qingdao Dagang Customs of the People's Republic of China, Guangzhou Institute of Quality Supervision and Inspection, Taicang of the People's Republic of China customs | Administrative Organization | National Plastics Standardization Technical Committee (SAC/TC 15) | Proposing organization | China Petroleum and Chemical Industry Federation | Issuing agency(ies) | State Administration for Market Regulation, National Standardization Administration |
GB/T 38286-2019
Polyethylene (PE), polypropylene (PP) and polystyrene (PS) resin--Determination of peroxide value
ICS 83.080.01
G31
National Standards of People's Republic of China
Polyethylene, polypropylene, polystyrene resin
Determination of peroxide value
2019-12-10 release
2020-11-01 implementation
State Administration of Market Supervision and Administration
Issued by the National Standardization Management Committee
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the China Petroleum and Chemical Industry Federation.
This standard is under the jurisdiction of the National Plastic Standardization Technical Committee (SAC/TC15).
This standard was drafted by. China Inspection and Certification Group Ningbo Co., Ltd., Ningbo Customs of the People's Republic of China, Guangzhou Special Pressure Equipment
Inspection Research Institute, China Blue Chenguang Chengdu Inspection Technology Co., Ltd., Qingdao Dagang Customs of the People's Republic of China, Guangzhou Quality Supervision and Inspection Research
Institute, Taicang Customs of the People's Republic of China.
The main drafters of this standard. Wu Beilei, Ye Jiamei, Luo Chuan, Li Maodong, Luo Xiaoxia, Chen Minjian, Gao Jianguo, Wang Wanjuan, Huang Guo, Song Changsheng
Yu Qiaoling.
Polyethylene, polypropylene, polystyrene resin
Determination of peroxide value
1 Scope
This standard specifies the method for determining the peroxide value of polyethylene, polypropylene and polystyrene resins.
This standard is applicable to the determination of peroxide value of polyethylene, polypropylene and polystyrene resins.
Note. Other resins can be measured with reference to this standard.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
Preparation of GB/T 601 chemical reagent standard titration solution
GB/T 6682 Analysis laboratory water specifications and test methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Peroxide value
Ip
The amount of peroxide that can react with sodium thiosulfate in the sample is expressed in millimoles of active oxygen contained in 1000g of sample.
4 Method summary
The sample is immersed in the mixed solution of chloroform/acetic acid, the peroxide dissolved in the solution reacts with the excess potassium iodide solution to generate iodine, and sulfur
Titrate with sodium titrate standard titration solution to calculate the peroxide value of the sample.
5 Reagents and materials
Warning --- Chloroform is a volatile solvent. In order to avoid possible poisoning of the reagents, please protect and keep the experiment personnel in use.
Good ventilation.
Unless otherwise specified, the reagents used are of analytical grade, and the experimental water should meet the requirements of secondary water specified in GB/T 6682.
5.1 Chloroform. superior grade pure.
5.2 Acetic acid. pure grade.
5.3 Chloroform/acetic acid mixed solution. Mix according to the volume ratio of 2. 3.
5.4 Saturated potassium iodide solution. 14g potassium iodide, add 10mL of water to dissolve, ensure that there are insoluble crystals, sealed and protected from light.
5.5 Sodium thiosulfate solution. c (Na2S2O3) = 0.1mol/L. Prepare and calibrate according to the requirements of GB/T 601.
5.6 Sodium thiosulfate standard titration solution. c (Na2S2O3) = 0.01mol/L. It is obtained by diluting 5.5 times by 5.5.
......
|