HOME   Cart(2)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 38021-2019 English PDF

US$184.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 38021-2019: Analogue quartz clocks - Timing accuracy
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 38021-2019English184 Add to Cart 3 days [Need to translate] Analogue quartz clocks - Timing accuracy Valid GB/T 38021-2019

PDF similar to GB/T 38021-2019


Standard similar to GB/T 38021-2019

GB/T 38023   GB/T 30106   QB/T 4055.2   GB/T 38020.2   GB/T 38020.1   

Basic data

Standard ID GB/T 38021-2019 (GB/T38021-2019)
Description (Translated English) Analogue quartz clocks - Timing accuracy
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y11
Classification of International Standard 39.040.20
Word Count Estimation 10,194
Date of Issue 2019-08-30
Date of Implementation 2020-03-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 38021-2019: Analogue quartz clocks - Timing accuracy

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Analogue quartz clocks - Timing accuracy ICS 39.040.20 Y11 National Standards of People's Republic of China Pointer quartz clock travel accuracy (ISO 19235.2015, IDT) Published on.2019-08-30 2020-03-01 implementation State market supervision and administration China National Standardization Administration issued

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the translation method equivalent to ISO 19235.2015 "pointer type quartz clock travel time accuracy". This standard was proposed by the China Light Industry Association. This standard is under the jurisdiction of the National Clock Standardization Technical Committee (SAC/TC160). This standard was drafted. Shenzhen Jinbawang Precision Electronics Co., Ltd., Shenzhen Titan Clock Technology Co., Ltd., Xi'an Light Industry Clock Table Research Co., Ltd., Yantai Polaris State-owned Holdings Co., Ltd., Shengzhou Hengli Electronics Co., Ltd., Changzhou Jingke Industrial Co., Ltd. Fujian Shangrun Precision Instrument Co., Ltd., Fujian Shengbang Electronic Technology Co., Ltd., Guangzhou Fuda Watch Industry Co., Ltd., Fujian Ruida Seiko Co., Ltd., Fujian Jibang Electronics Co., Ltd., Yantai Long-lasting Watch Group Co., Ltd. The main drafters of this standard. Zhu Jihua, Yin Xiaoyu, Wang Yanmin, He Guangxian, Jin Yingshu, Yu Hongyun, Yu Chengbo, Shao Yueming, Lan Liping, Sun Gang, Su Fangzhong, Lin Jian, Wu Xiaolin, Luo Xiaomei, Jiang Wei, Li Xia, Chen Yili, Qiu Xuqiang, Sun Yukai. Pointer quartz clock travel accuracy

1 Scope

This standard specifies the basic parameters, requirements and test methods for the accuracy of the walking time of the quartz clock (hereinafter referred to as "quartz clock"). This standard is applicable to the quartz quartz clock and wall clock with crystal frequency of 32768Hz and nominal voltage of DC1.5V. The bell heart can also be used as reference. This standard does not apply to the following quartz clocks. ---Special use of the clock on aircraft, ships, vehicles and other equipment; ---The clock matched with other products; --- Radio clock.

2 Terms and definitions

The following terms and definitions apply to this document. 2.1 Average instantaneous difference melaninstantaneousrate 􀭿m The arithmetic mean of the three instantaneous differences of the quartz clocks tested in consecutive 3d, in units of "s/d" or "s/month". 2.2 Voltage coefficient CU The rate of change of the instantaneous difference in the quartz clock due to changes in the supply voltage. 2.3 Temperature coefficient Ct The rate of change of the instantaneous difference in the quartz clock due to temperature changes. 2.4 Nominal voltage nominalvoltage Un The voltage identified by the movement.

3 Basic parameters and requirements for travel time accuracy

3.1 Average instantaneous difference 􀭿m After the quartz clock is continuously transported for 3 days, the average instantaneous difference should be in the range of -1.0 s/d to 1.0 s/d. 3.2 Voltage coefficient CU The voltage coefficient CU should be in the range of -1.0 s/(d · V) ~ 1.0 s/(d · V).

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 38021-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 38021-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 38021-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 38021-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.