Search result: GB/T 37900-2019
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 37900-2019 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Test method of hardness and fracture toughness for ultra-thin glass - Low-load Vickers hardness indentation method
| Valid |
GB/T 37900-2019
|
Standard ID | GB/T 37900-2019 (GB/T37900-2019) | Description (Translated English) | Test method of hardness and fracture toughness for ultra-thin glass -- Low-load Vickers hardness indentation method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | Q30 | Classification of International Standard | 81.040.10 | Word Count Estimation | 10,177 | Date of Issue | 2019-08-30 | Date of Implementation | 2020-07-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 37900-2019
Test method of hardness and fracture toughness for ultra-thin glass - Low-load vickers hardness indentation method
ICS 81.040.10
Q30
National Standards of People's Republic of China
Ultra-thin glass hardness and fracture toughness test method
Small load Vickers hardness indentation method
Published on.2019-08-30
2020-07-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the China Building Materials Federation.
This standard is under the jurisdiction of the National Industrial Glass and Special Glass Standardization Technical Committee (SAC/TC447).
This standard was drafted. China Building Materials Inspection and Certification Group Co., Ltd., China Building Materials Science Research Institute Co., Ltd., Jiang
Sutie Anchor Glass Co., Ltd., Fuling Qibin Electronic Glass Co., Ltd.
The main drafters of this standard. Liu Xiaogen, Bao Yiwang, Wan Detian, Wang Yinmao, Liu Songhua, Qiu Yan, Tu Yi, Tian Yuan, Sun Hekang, Liu Baihui,
Pan Ruina, Ma Delong, Wang Yanping, Ai Fuqiang.
Ultra-thin glass hardness and fracture toughness test method
Small load Vickers hardness indentation method
1 Scope
This standard specifies the hardness and fracture toughness of ultra-thin glass measured by Vickers indentation method with loading force of 1.961N~49.03N.
Language and definition, test principle, test equipment, specimens, tests, calculation of results, marking and test reports.
This standard is applicable to the hardness test of glass with a thickness of 0.1mm~1.1mm and the breakage of glass with a thickness of 0.3mm~1.1mm.
Crack toughness test.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4340.2 Vickers hardness test for metallic materials - Part 2. Examination and calibration of durometer
GB/T 16534 fine ceramics room temperature hardness test method
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Small load Vickers hardness low-loadvickersindentation
The load of 1.961N~49.03N is used to press the Vickers indenter into the surface of the sample to form an indentation. The load is divided by the diagonal according to the indentation.
The value obtained by calculating the indentation surface area from the line length average.
3.2
Vickers indentation fracture toughness vickersindentationfracturetoughness
With a certain load, the diamond Vickers indenter is pressed into the surface of the sample to form an indentation, and pre-cracks are generated at the four vertices of the indentation.
The value calculated from the load and the indentation crack propagation length.
4 Test principle
A square tapered diamond indenter with an angle of 136° on the opposite side is pressed into the surface of the specimen at a given test pressure and maintained at the specified
After the time, the test force is removed, and the length of the two diagonal lines of the indentation and the length of the diagonal crack propagation of the indentation are measured by a microscope, according to a given meter.
Calculate the formula and calculate the hardness and fracture toughness of the sample surface. The schematic diagram of the test principle is shown in Figure 1. The indentation morphology and diagonal and diagonal cracks
The schematic diagram of the length measurement is shown in Figure 2.
......
|