US$199.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37617-2019: Test methods for Zeta potential of nanofiltration membrane surface - Streaming potential measurement Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 37617-2019 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Test methods for Zeta potential of nanofiltration membrane surface - Streaming potential measurement
| Valid |
GB/T 37617-2019
|
PDF similar to GB/T 37617-2019
Basic data | Standard ID | GB/T 37617-2019 (GB/T37617-2019) | | Description (Translated English) | Test methods for Zeta potential of nanofiltration membrane surface - Streaming potential measurement | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | J77 | | Classification of International Standard | 07.060; 23.100.60 | | Word Count Estimation | 10,158 | | Date of Issue | 2019-06-04 | | Date of Implementation | 2020-05-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 37617-2019: Test methods for Zeta potential of nanofiltration membrane surface - Streaming potential measurement ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for Zeta potential of nanofiltration membrane surface--Streaming potential measurement
ICS 07.060; 23.100.60
J77
National Standards of People's Republic of China
Nanofiltration membrane surface zeta potential test method
Flow potential method
Published on.2019-06-04
2020-05-01 implementation
State market supervision and administration
China National Standardization Administration issued
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed and managed by the National Separation Membrane Standardization Technical Committee (SAC/TC382).
This standard was drafted. Tianjin Membrane Engineering Technology Co., Ltd., Yantai Jinzheng Environmental Protection Technology Co., Ltd., Tianjin Membrane Technology Group
Co., Ltd., Shandong Zhaojin Membrane Co., Ltd., Jiangsu Jiuwu High-Tech Co., Ltd., Hangzhou Tianchuang Environmental Technology Co., Ltd.
Company, Tianjin Polytechnic University, Anton Paar (Shanghai) Trading Co., Ltd., Time Wharton Technology Co., Ltd., National Oceanic Administration Tianjin Seawater Desalination
Comprehensive use of research institutes.
The main drafters of this standard. Fan Yunshuang, Wang Wei, Miao Jing, Hu Xiaoyu, Wang Xuliang, Wang Le translation, Peng Wenbo, Wang Yanfeng, Li Yeping,
Wang Siliang.
Nanofiltration membrane surface zeta potential test method
Flow potential method
1 Scope
This standard specifies the principle, instrument, conditions and steps for testing the zeta potential of the nanofiltration membrane surface by the flow potential method.
This standard applies to the test of zeta potential on the surface of flat nanofiltration membrane. Other flat membranes, tubular membranes and external pressure hollow fiber membranes Zeta
The potential test can be used as reference.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 6682-2008 Analytical laboratory water specifications and test methods
GB/T 6904 Determination of pH in industrial circulating cooling water and boiler water
GB/T 6908 Boiler water and cooling water analysis methods - Determination of conductivity
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Nanofiltration membrane
A semipermeable membrane for removing multivalent ions, partially monovalent ions, and organic substances having a relative molecular mass greater than.200.
Note. Rewrite GB/T 20103-2006, definition 4.1.2.
3.2
Zeta potential Zetapotential
The potential difference between the sliding surface in the membrane-liquid electric double layer structure and the solution body.
3.3
Flow potential
When the electrolyte solution flows in a capillary channel, the free charged particles in the solid-liquid interface diffusion layer flow along the solution flow direction.
The potential difference across the capillary channel produced by the motion.
4 Test principle
During the membrane separation process, some functional groups on the surface of the membrane are dissociated or protonated, or the surface of the membrane is charged by some adsorption.
Sexuality, so that the membrane-liquid interface is different from the main body of the solution, which can be described by the theory of electric double layer structure, in which zeta potential
The size reflects the chargeability of the film surface. The Zeta potential cannot be measured directly and can be measured indirectly by the flow potential.
5 main reagents
The test reagents are as follows.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37617-2019_English be delivered?Answer: Upon your order, we will start to translate GB/T 37617-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 37617-2019_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37617-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|