US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 36063-2018: Nanotechnologies -- Raman shift standard curve for spectrometer calibration Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 36063-2018 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Nanotechnologies -- Raman shift standard curve for spectrometer calibration
| Valid |
GB/T 36063-2018
|
PDF similar to GB/T 36063-2018
Basic data Standard ID | GB/T 36063-2018 (GB/T36063-2018) | Description (Translated English) | Nanotechnologies -- Raman shift standard curve for spectrometer calibration | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | N35 | Classification of International Standard | 17.180.30 | Word Count Estimation | 14,133 | Date of Issue | 2018-03-15 | Date of Implementation | 2018-10-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 36063-2018: Nanotechnologies -- Raman shift standard curve for spectrometer calibration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Nanotechnologies--Raman shift standard curve for spectrometer calibration
ICS 17.180.30
N35
National Standards of People's Republic of China
Nanotechnology for Raman Spectroscopy Calibration
Standard Raman frequency shift curve
Published by.2018-03-15
2018-10-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Administration released
Directory
Preface III
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Overview 1
5 Calibration Condition 1
6 Raman frequency shift calibration 1
7 Uncertainty assessment 2
8 Report 3
Appendix A (informative annex) Raman frequency shift calibration curve measurement method 4
Appendix B (Informative Appendix) Raman Frequency Shift Calibration Curve Report Format 7
Reference 8
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard was proposed by the Chinese Academy of Sciences.
This standard is under the jurisdiction of the National Nanotechnology Standardization Technical Committee (SAC/TC279).
This standard was drafted by. China Academy of Metrology, Qingdao Haishu Group Co., Ltd.
The main drafters of this standard. Ren Lingling, Yao Yayi, Gao Huifang, Wang Xunlong.
Introduction
Raman spectroscopy has become a major measurement in the field of nanotechnology with its unique information, rich information, simple sample preparation, and no damage to the sample.
One of the characterization means. With the development of new materials such as fullerenes, graphene, and carbon nanotubes and high-tech industries such as MEMS and semiconductors,
As the requirements for the characterization and measurement of microstructures and stress effects continue to increase, so does the accuracy of Raman frequency shift measurements. such as
The Raman frequency shift is closely related to the structure of the material. Its minor changes, in addition to the qualitative nature of the material, can also reflect charge doping and deformation stress.
Therefore, the calibration of the Raman shift has significant implications for the development of Raman spectroscopy.
The development of this standard will provide methods for the calibration of Raman shifts using standard substances and the uncertainty introduced by the calibration process for Raman
The comparable and reliable basis for the frequency shift measurement results promotes the use and development of Raman spectroscopy in nanotechnology and other fields.
Nanotechnology for Raman Spectroscopy Calibration
Standard Raman frequency shift curve
1 Scope
This standard specifies the terms and definitions of Raman shift calibration curves, calibration conditions, Raman shift calibration, and uncertainty assessment.
This standard applies to Raman spectrometer (hereinafter referred to as the instrument) Raman frequency shift calibration.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 33252-2016 Nanotechnology Laser Confocal Microscopy Raman Spectrometer Performance Test
3 Terms and definitions
The terms and definitions defined in GB/T 33252-2016 apply to this document.
4 Overview
Raman spectroscopy is a molecular scattering spectrometer that produces modulated frequencies due to inelastic scattering when the material is exposed to monochromatic radiation energy.
The spectrum. The Raman frequency shift is closely related to the structure of the material. Its minor changes, in addition to the qualitative nature of the material, can also reflect the charge doping and shape.
The stress is changed, so the Raman shift needs to be calibrated. When Raman spectrometers are used, monocrystalline silicon is generally used for preliminary calibration to check the instrumentation.
state. When performing measurements, linear calibration of multiple Raman shifts across the entire raster range is required. At this point, the calibration of the Raman shift needs to be established
Curves, and find the linear correlation coefficient of the calibration curve. This standard provides comparable and reliable basis for Raman frequency shift measurement results and promotes Raman
The use and development of spectroscopy in nanotechnology and other fields.
5 calibration conditions
5.1 Laboratory conditions
The ambient temperature is 20 °C ~ 25 °C, the use of temperature fluctuation range does not exceed ± 2 °C. Relative humidity ≤ 60%.
5.2 Instrument warm-up
Turn on the laser before testing. Preheat and settling times follow the instructions for the instrument.
6 Raman frequency shift calibration
6.1 Selection of reference materials
Select the certified reference material that covers the Raman shift range of the sample to be tested. To meet the above conditions, it is advisable to select a solid and liquid sample
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 36063-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 36063-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 36063-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36063-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|