US$359.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 35734-2017: Portable tube-excited X-ray fluorescence analysis equipment -- Classification, safety requirements and test Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 35734-2017 | English | 359 |
Add to Cart
|
4 days [Need to translate]
|
Portable tube-excited X-ray fluorescence analysis equipment -- Classification, safety requirements and test
| Valid |
GB/T 35734-2017
|
PDF similar to GB/T 35734-2017
Basic data Standard ID | GB/T 35734-2017 (GB/T35734-2017) | Description (Translated English) | Portable tube-excited X-ray fluorescence analysis equipment -- Classification, safety requirements and test | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | F86 | Classification of International Standard | 27.120 | Word Count Estimation | 18,198 | Date of Issue | 2017-12-29 | Date of Implementation | 2018-07-01 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 35734-2017: Portable tube-excited X-ray fluorescence analysis equipment -- Classification, safety requirements and test ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Portable tube-excited X-ray fluorescence analysis equipment - Classification, safety requirements and test
ICS 27.120
F86
National Standards of People's Republic of China
Portable tube excitation X-ray fluorescence analyzer
Classification, safety requirements and tests
Classification, safetyrequirementsandtest
(IEC 62495..2011, Nuclearinstrumentation-PortableX-ray
fluorescenceanalysisequipmentutilizingaminiatureX-raytube, MOD)
2017-12-29 Posted
2018-07-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
Introduction IV
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 General Requirements 2
5 Portable XRF Analyzer Requirements 3
6 Warning signs and instructions 6
7 Test 7
Appendix A (Informative) Impact of the recommended value and range 11
Reference 13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafted law to amend the use of IEC 62495..2011 "nuclear instrumentation portable tube excitation X-ray fluorescence analyzer."
This standard IEC 62495..2011 technical differences and the reasons are as follows.
--- On normative references, this standard made a technical difference with the adjustment to adapt to China's technical conditions, adjust the situation
Concentration reflected in the second chapter "Normative references", the specific adjustments are as follows.
● Replacing IEC 60982. 1989 with GB/T 11923 that does not equivalently adopt international standards;
● Replace IEC 60692..1999 with GB/T 13980, which is not equivalent to international standards;
● Replacing IEC 61336..1996 with GB/T 15636 that is not equivalent to international standards;
● IEC 61326 (all parts) replaced by GB/T 18268 (all parts) that is not equivalent to international standards;
● increase the reference GB 18871-2002;
● increase the reference GB/T 31364-2015.
--- Chapter 3, "Terms and definitions", according to the standard using the circumstances were cut and the order of adjustments; delete the "collimation device" "Probing
Box "" Circuit measurement device "" Handheld device "" Measuring head "under" normal conditions "" portable device "" radiation generating device "" Department
System Shield "" alarm device "" X-ray fluorescence measurement system "a total of 11 terms;
--- Added 5.5.2.3 "distance sensor", the two types of sensors described in 5.5.2.2.2 and 5.5.2.2.3 as "distance sensor";
--- 7.2 Added 7.2.1,7.2.2,7.2.3,7.2.4, a clear electromagnetic compatibility test technical requirements and test methods.
This standard made the following editorial changes.
--- In line with the existing standard series, the standard name changed to "portable tube excitation X-ray fluorescence analyzer classification, safety
Seeking its test ";
--- Added "Introduction", IEC 62495..2011 in Chapter 1 of the standard preparation purposes and the "portable tube excited X-ray fluorescence
Optical analyzer "profile into the" Introduction ";
--- Chapter 1 "Range" According to GB/T 1.1-2009 requirements, an increase of "This standard specifies the portable tube excitation X-ray fluorescence analysis
Terms and definitions of instruments, classification, safety requirements and tests, and warning labels and instructions. ";
--- Chapter 6 "Warning signs and instructions" According to our standard habits, will be marked that a unified representation;
--- Added Table A.1, Appendix A of the ambient temperature and relative humidity and other parameters are placed in Table A.1;
--- Reference lists an increase of the reference to the relevant national standards and industry standards of our country.
This standard proposed by China National Nuclear Corporation.
This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized.
This standard was drafted. Institute of High Energy Physics, Chinese Academy of Sciences.
The main drafters of this standard. Wei Long, Zhao Jingwei, Xiong Zhenglong, Feng Minzi, Guo Jing, Li Zhuoxin.
Introduction
This standard is intended for portable tube excitation X-ray fluorescence analyzer (hereinafter referred to as portable XRF analyzer) and radiological safety related
Design and operation of, and experimentation with, performance specifications for common radiation, electrical, safety and environmental characteristics to minimize and avoid
Health risks during use. Portable XRF analyzer general performance and test methods see GB/T 31364-2015.
Portable fluorescence analyzers using low-power, small x-ray tubes as ionizing radiation sources represent a new type of industrial equipment. use
Portable analyzers with small X-ray tubes to replace radioisotope sources (eg, 55Fe, 57Co, 109Cd, 241Am and 244Cm) have been used
Such as the analysis of lead in paint, alloy identification, screening of soil containing harmful substances.
Portable tube excitation X-ray fluorescence analyzer
Classification, safety requirements and tests
1 Scope
This standard specifies the terms and definitions portable pipe excitation X-ray fluorescence analyzer, classification, safety requirements and test and warning
Marks and instructions.
This standard applies to the use of small X-ray tube as a commercial application of ionizing radiation source portable fluorescence analyzer.
This standard does not apply to the following X-ray fluorescence (XRF) analyzer.
a) Portable XRF analyzers using radioactive sources;
b) Large, fixed-mount XRF analyzers using X-ray tubes;
c) Portable XRF analyzers for veterinary and medical applications.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 11923 ionizing radiation level gauge (GB/T 11923-2008, IEC 60982. 1989, NEQ)
GB/T 13980 ionizing radiation densitometer (GB/T 13980-2008, IEC 60692..1999, NEQ)
GB/T 15636 ionizing radiation thickness gauge (GB/T 15636-2008, IEC 61336..1996, NEQ)
GB/T 18268 (all parts) Electromagnetic compatibility requirements for electrical equipment for measurement, control and laboratory use (GB/T 18268,
IEC 61326, NEQ)
Basic ionizing radiation protection and radiation source safety standards
Energy dispersive X - ray fluorescence spectrometer the main performance test methods GB/T 31364-2015
IEC 61010-1..2010 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1. General requirements (Safetyre-
quirementsforelectricalequipmentformeasurement, control, andlaboratoryuse-Part 1. Generalre-
quirements
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
X-ray system X-raysystem
A collection of components that produce and use x-rays, including x-ray generators and x-ray ancillary equipment.
3.2
X-ray generator X-ray generator
X-ray systems include X-ray tubes and components that provide accelerated (high) voltage and current to the X-ray tube.
3.3
X-ray accessory X-ray accessoryapparatus
Any part of the x-ray device that is external to the x-ray generator and through which the x-ray beam passes and is being measured or otherwise used.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 35734-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 35734-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 35734-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 35734-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|