HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 34926-2017 English PDF

US$759.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 34926-2017: Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34926-2017English759 Add to Cart 7 days [Need to translate] Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV Valid GB/T 34926-2017

PDF similar to GB/T 34926-2017


Standard similar to GB/T 34926-2017

GB/T 31489.4   GB/T 34016   GB/T 33594   GB/T 29631   GB/T 11017.1   

Basic data

Standard ID GB/T 34926-2017 (GB/T34926-2017)
Description (Translated English) Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 38,398
Date of Issue 2017-11-01
Date of Implementation 2018-05-01
Regulation (derived from) National Standard Announcement 2017 No. 29
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34926-2017: Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1 kV ICS 29.060.20 K13 National Standards of People's Republic of China Rated voltage 0.6/1kV and below mica with minerals Insulation corrugated copper sheath cable and terminal Posted.2017-11-01 2018-05-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 classification, code, specifications and markings, the use of features 3 5 technical requirements 9 6 Test conditions 13 7 routine test 14 8 sampling test 15 Electrical type test 18 10 Non-electrical type test 19 11 terminal 21 12 Inspection Rules 22 13 logos and labels 23 14 Packaging, transport and storage 23 Appendix A (Normative) Determination of protective layer thickness and non-metallic outer sheath thickness of the assumed value calculation method 25 Appendix B (Normative) Mica tape performance 28 Appendix C (Informative) Low-smoke halogen-free flame retardant tape performance 30 Appendix D (informative) cable reference diameter 31 Appendix E (Informative) Cable Terminal Schematic 33 Appendix F (normative) numerical repair about 34 References 35

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the China Electrical Equipment Industry Association. This standard by the National Standardization Technical Committee wire and cable (SAC/TC213) centralized. This standard was drafted. Shanghai Pudong Wire and Cable (Group) Co., Ltd., the State Quality Supervision and Testing Center for Wire and Cable, Shanghai Sheng Wu Cable Co., Ltd., Jiangsu Shangshang Cable Group Co., Ltd., Jiangsu Hengtong Power Cable Co., Ltd., Far East Cable Co., Ltd., Shanghai Pudong Mineral Cable Co., Ltd., Guangxi Cable Technology Group Co., Ltd., Chongqing Three Gorges Cable (Group) Co., Ltd., Jinbei Electric Hengyang Electric Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Zhejiang Wanma Co., Ltd., Shanghai Shenghua Electric Co., Ltd., Guangzhou Nanyang Electric Cable Co., Ltd., Anhui Hui Ning Electric Instrument Group Co., Ltd., Anhui Pacific Cable Co., Ltd., Hangzhou Cable Co., Ltd., Chung Chen Cable Co., Ltd., Sichuan Star Cable Co., Ltd., Hunan Golden Dragon Cable Co., Ltd., Xingle Group Co., Ltd., Hebei Dehao Cable Co., Ltd., Shandong Hualing Cable Co., Ltd., Anhui Huaxing Cable Group Co., Ltd., East China Architectural Design and Research Institute, Liaoning Provincial Architectural Design and Research Institute, Shanghai Architectural Design and Research Institute Co., Ltd., Beijing Institute of Architectural Design Co., Ltd., Shenzhen City Architectural Design Research Institute Co., Ltd. The main drafters of this standard. Chen Wei, Wu Changshun, Zhang Rongsheng, Li Bin, Guan Xinyuan, Xu Jing, Chen Yuhua, Chen Zenan, Pan Zhihua, Chen Hao, He Jincun, Chen Shanqiu, Ma Zhuang, Liu Huanxin, Wang Jianzhong, Wang Zhihui, Zhang Yuanjian, Wang Yishan, Teng Zhaofeng, Bai Qingmei, Chen Guanggao, Mo Xia, Yu Jingfeng, Wu Jian, Li Guangjie, Wu Junsheng, Qian Guanrong, Sun Shengjin, Jiang Ming, Wang Meng, Chen Weisong. Rated voltage 0.6/1kV and below mica with minerals Insulation corrugated copper sheath cable and terminal

1 Scope

This standard specifies the terms and definitions mica with mineral insulated ripple copper sheathing cables and terminations rated voltage 0.6/1kV and below, points Classes, Codes, Models, Specifications and Markings, Characteristics of Use, Technical Requirements, Tests, Inspection Rules, Signs and Labels, Packaging, Transport and Storage. This standard applies to the rated voltage 0.6/1kV susceptible to the spread of fire or direct impact of fire and other places for power transmission with the mica tape Mineral insulated corrugated copper sheathed power cables and terminals, and the rated voltage 450/750V susceptible to the spread of fire or fire directly affect the field Controlled, monitoring circuit and the protection of mica cable with mineral insulated ripple copper sheath control cables and terminals.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Copper and copper alloy strip GB/T 2900.10 Electrotechnical terminology cables GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 11. Thickness of common test methods Mechanical and performance tests on dimensions and dimensions GB/T 3048.4-2007 wire and cable electrical performance test methods - Part 4 DC conductor resistance test GB/T 3048.5-2007 wire and cable electrical performance test methods Part 5. Insulation resistance test GB/T 3048.8-2007 Electrical wire and cable test methods - Part 8. AC voltage test Conductor for GB/T 3956-2008 cables Mica - based insulating materials - Part 2. Test methods GB/T 6995.3-2008 wire and cable Identification Marking Methods Part 3. Wire and Cable Identification Mark GB/T 6995.5-2008 wire and cable identification methods - Part 5. Power cable insulated core identification mark Plastic insulated control cables - Part 1. General provisions GB/T 12706.1-2008 Rated voltage 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) extruded insulated power cables And accessories Part 1. Rated voltage 1kV (Um = 1.2kV) and 3kV (Um = 3.6kV) cable GB/T 17650.2-1998 Test methods for the release of gases on combustion of materials from cables or cables - Part 2. Measurement with pH and conductivity to determine the gas acidity General rules of flame-retardant and fire-resistant wire and cable GB/T 19666-2005 Tobacco toxicity toxicity classification according to GB/T 20285-2006 High Voltage Cable Selection Guide YS/T 649 copper and copper alloy rod Insulating hoses - Part 2. Insulating hoses (Flexibleinsulatingsleeving - Part 2. Methodsoftest) BS6387.2013 Fire conditions in the cable line integrity test fire test method (Testmethodforresistanceto fireofcablesrequiredtomaintaincircuitintegrityunderfireconditions) BS8491.2008 fire-resistant integrity of large-diameter power cables used as components of smoke and heat control systems and other active fire safety systems

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 34926-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 34926-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 34926-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 34926-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.