GB/T 34554-2017: Test method of structural adhesion reliability for building glass curtain wall
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34554-2017English279 Add to Cart 3 days [Need to translate] Test method of structural adhesion reliability for building glass curtain wall Valid GB/T 34554-2017

PDF similar to GB/T 34554-2017


Standard similar to GB/T 34554-2017

GB/T 38264   GB/T 38388   GB/T 34555   GB/T 34553   

Basic data

Standard ID GB/T 34554-2017 (GB/T34554-2017)
Description (Translated English) Test method of structural adhesion reliability for building glass curtain wall
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard P32
Classification of International Standard 91.060.10
Word Count Estimation 14,189
Date of Issue 2017-10-14
Date of Implementation 2018-09-01
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34554-2017: Test method of structural adhesion reliability for building glass curtain wall

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method of structural adhesion reliability for building glass curtain wall ICS 91.060.10 P32 National Standards of People's Republic of China Building glass curtain wall bonding structure Reliability test methods 2017-10-14 Published 2018-09-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 test principle 2 5 test conditions 2 5.1 Data Preparation 2 5.2 Test Preparation 2 6 equipment 3 6.1 equipment requirements 3 6.2 equipment installation 3 7 test pieces 4 8 Test Procedure 4 Determination of the initial stiffness modulus of silicone structural sealants 4 8.2 silicone structural sealant test displacement limit calculation 4 8.3 Glass curtain wall point load - displacement coefficient calculation 5 8.4 Monolithic glass curtain wall bonding structure reliability test method 5 8.5 Hollow glass curtain wall bonding structure reliability test method 6 9 Test Report 7 Appendix A (Informative) Building Glass Curtain Wall Adhesion Structure Reliability Test Report

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China. This standard by the National Building Curtain wall Standardization Technical Committee (SAC/TC448) centralized. This standard is drafted by China Academy of Building Research, Guangzhou Baiyun Chemical Industry Co., Ltd., Guangzhou set Thai Chemical Co., Ltd. Limited company. Participated in the drafting of this standard. Shenzhen Branch source Construction Group Co., Ltd., Zhengzhou Zhongyuan Applied Technology Research and Development Co., Ltd., Chengdu Si Bao Technology Co., Ltd., Hangzhou Zhijiang Silicone Chemical Co., Ltd., Dow Corning (China) Investment Co., Ltd., Momentive high-tech materials Mission, Shanghai Academy of Building Research (Group) Co., Ltd., Guangdong Academy of Building Research Group Co., Ltd., Fujian Provincial Construction Department Institute of Science, Henan Academy of Building Research Co., Ltd., Beijing Jianghe Creation Group Co., Ltd., Beijing Gangyuan Curtain Wall Co., Ltd., Zhejiang Lexus Chemical Co., Ltd., Guangzhou Coats Industrial Co., Ltd., Hubei days back to New Materials Co., Ltd., Jiangmen big bright viscose Limited Division, Guangzhou City, the new exhibition Silicone Co., Ltd. The main drafters of this standard. Zhang Xiaomin, Liu Ying, Ma Qiyuan, Jiang Guangming, Chen Ai Sen, Jiang Jinbo, Shi Zhengjin, Cui Hong, Wang Youzhi, Lai Yande, Xu Qin, Tao Wei, Li Guangxu, Wang Tianshu, Wang Wenkai, Liu Ming, Chen Shilong, Hu Xin Song, Wei Chunyan, Wang Cuihua, cold Yan Ping, Wang Ming Shuang, Wang Feng Ping. Building glass curtain wall bonding structure Reliability test methods

1 Scope

This standard specifies the terms and definitions, test principles, test conditions, equipment design test method of construction glass curtain wall adhesion structure Preparation, test pieces, test procedures, test reports. This standard applies to both the existing hidden frame and semi-hidden glass curtain wall adhesive structure in situ detection of reliability, does not apply to the use of mechanical connections Glass curtain wall reliability in situ testing.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. Statistical processing and interpretation of statistics - Determination of statistical tolerance interval GB/T 11944 insulating glass GB/T 14682 Building sealing materials terminology Building structural silicone sealants GB/T 19155 height operating basket JGJ80 Building Construction Height Operational Safety Technical Specifications JGJ102 glass curtain wall engineering specifications Hollow glass elastic sealant for door and window curtain wall of building

3 Terms and definitions

GB/T 11944 and GB/T 14682 define the following terms and definitions apply to this document. 3.1 Glass curtain wall adhesive structure adhesionstructureofglasscurtainwal Hidden frame and semi-hidden frame curtain wall panel glass and metal frame bonding molding structure. 3.2 Point load pointload Vertical load locally concentrated on curtain glass panels. 3.3 Test displacement limit testdisplacementlimit Building glass curtain wall bonding structure reliability test process, the maximum load of silicone structural sealant under the point load. 3.4 Selected point load selectedpointload Selected point loads based on field tests. At this point the load, the glass curtain wall bonding structure and the failure of the bonding structure of silicon Ketone structural sealant showed a significant difference in displacement.