HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 34142-2017 English PDF

US$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 34142-2017: Radiation protection instrumentation -- Highly sensitive hand-held instruments for photon detection of radioactive material
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 34142-2017English439 Add to Cart 4 days [Need to translate] Radiation protection instrumentation -- Highly sensitive hand-held instruments for photon detection of radioactive material Valid GB/T 34142-2017

PDF similar to GB/T 34142-2017


Standard similar to GB/T 34142-2017

GB/T 13286   NB/T 20318   GB/T 24247   GB/T 34138   GB/T 34138   

Basic data

Standard ID GB/T 34142-2017 (GB/T34142-2017)
Description (Translated English) Radiation protection instrumentation -- Highly sensitive hand-held instruments for photon detection of radioactive material
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F84
Classification of International Standard 13.280
Word Count Estimation 22,258
Date of Issue 2017-07-31
Date of Implementation 2017-11-01
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 34142-2017: Radiation protection instrumentation -- Highly sensitive hand-held instruments for photon detection of radioactive material


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Radiation protection instrumentation - Highly sensitive hand-held instruments for photon detection of radioactive material ICS 13.280 F84 National Standards of People's Republic of China Radiation protection equipment for photon detection of radioactive material Highly sensitive hand-held instrument Radiationprotectioninstrumentation-Highly sensitive and-heldinstruments (IEC 62533.2010, IDT) 2017-07-31 Posted 2017-11-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions, abbreviations, quantities and units 2 3.1 Terms and definitions 2 3.2 Abbreviations 4 3.3 volume and unit 5 4 General requirements 5 4.1 General characteristics 5 4.2 Physical Structure 5 4.3 basic information 5 4.4 Communication Interface 5 4.5 User Interface 6 4.6 warm-up time 6 4.7 logo 6 4.8 Power 6 4.9 Control and Protection 7 4.10 photon around the dose equivalent rate instructions 7 4.11 alarm 7 4.12 effective measurement range 7 4.13 Angle dependency 7 4.14 Explosive air 7 4.15 Indicator Features 7 5 General test methods 7 5.1 Experimental nature 7 5.2 Reference conditions and standard test conditions 8 5.3 Reference gamma radiation background 8 5.4 Statistics Fluctuation 8 6 Radiation test 9 6.1 (Source tips) false alarm rate 9 6.2 source alarm and response time 9 6.3 personal protection alarm and response time 9 6.4 around the dose equivalent rate indicator value 9 6.5 around the dose equivalent rate of overload indicator characteristics 10 7 additional features 10 7.1 Overview 10 7.2 mobile use removed when the natural changes encountered in the background 10 7.3 Classification of sources 10 Environmental, mechanical and electrical performance requirements 8.1 temperature test 11 8.2 humidity test 12 8.3 Dust and waterproof test 12 8.4 Mechanical tests 13 8.5 Collision (flutter) test 14 8.6 Electrical Tests 14 8.7 Radiofrequency radiation emission 15 Conducted harassment 16 8.9 Magnetic Field 16 9 file 17 9.1 Overview 17 9.2 Type Test Report 17 9.3 Certificate of Conformance 9.4 Operation and Maintenance Manual 17 References 18 Table 1 reference conditions and standard test conditions 8 Table 2 RF radiation emission limits 16

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard uses the translation method identical with IEC 62533.2010 "Radiation protection instrumentation for photon detection of radioactive substances highly sensitive Handheld instrument. " The documents of our country that have consistent correspondence with the international standards that are normative references in this standard are as follows. --- GB/T 4208-2008 enclosure protection (IP code) (IEC 60529.2001, IDT); Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2). 2001, IDT); --- GB/T 17626.3-2006 Electromagnetic compatibility test and measurement techniques RF electromagnetic field radiation immunity test (IEC 61000-4-3.2002, IDT); --- GB/T 17626.6-2008 electromagnetic compatibility test and measurement techniques RF field induced conduction disturbances immunity (IEC 61000-4-6.2006, IDT). This standard proposed by China National Nuclear Corporation. This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized. This standard was drafted unit.Nuclear Industrial Standardization Institute, Xiamen City, metrological testing institute, Xiamen Minya Zhongmin Electronic Technology Co., Ltd.. The main drafters of this standard. Zhang Jingchang, Zheng Peng, Ling Winter root. Radiation protection equipment for photon detection of radioactive material Highly sensitive hand-held instrument

1 Scope

This standard applies to the detection and positioning of photons emitted radioactive handheld devices. These highly sensitive instruments are designed primarily for the purpose Used to detect subtle changes within the normal background caused by the illicit trafficking or unintentional transfer of radioactive material. With pocket-sized instrument (See GB/T 31835-2015), high-sensitivity instruments allow scanning large volume items such as vehicles or containers. In order to monitor the inspection Points or hazardous areas, these instruments also allow fixed or temporarily fixed unattended use. These instruments also provide ambient dose equivalent rate indications generated by photon radiation. However, this standard does not apply to GB/T 4835.1-2012 And GB/T 13161-2015 radiation protection equipment involved in the performance. These instruments provide the following additional functions (not including the portable instruments specified in GB/T 31837-2015 for nuclide identification All the features). --- When used in the movement, the suppression of natural background fluctuations; --- According to the concerns of natural radioactive substances (NORM) alarm or medical radionuclide alarm classification; --- Remote source classification data (including limited photon spectrum). The purpose of this standard is to establish performance requirements, including physical characteristics, general test conditions, radiation characteristics, electrical safety and environmental conditions. In order to determine whether the instrument meets the requirements of this standard, this standard provides examples of acceptable test methods. Test results provide users with spokes Radiation detection equipment reliable detection of photon source capability information. Equipment to meet or exceed the technical requirements of this standard performance requirements depend on the correct establishment of appropriate working parameters, the implementation of school Proper implementation of appropriate response testing and maintenance procedures, formal training of operators and development of exercises that take into account instrument limitations and capabilities As a method.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 2423.55-2006 Environmental testing for electric and electronic products Part 2. Environmental test Eh. Hammer test (IEC 60068-2-75.1997, IDT) GB/T 2900.81-2008 Electrotechnical terminology Nuclear physics and basic concepts (IEC 60050-393.2003, IDT) GB/T 2900.82-2008 Electrotechnical terminology Instruments Instruments, systems, equipment and detectors (IEC 60050-394.2007, IDT) Part 1. X and gamma reference radiations for calibration of dosimeters and dose rate meters and determination of their response. Radiation characteristics and methods of production (ISO 4037-1.1996, IDT) X and gamma reference radiations for the calibration of dosimeters and dose rate meters and determination of their response - Part 2. GB/T 12162.2-2004. Radiation protection with the energy range of 8keV ~ 1.3MeV and 4MeV ~ 9MeV reference radiation dosimetry (ISO 4037-2. 1997, IDT) X and gamma reference radiations for the calibration of dosimeters and dose rate meters and determination of their response - Part 3. GB/T 12162.3-2004. Calibration of site dosimeters and personal dosimeters and determination of their energy response and angular response (ISO 4037-3.1999, IDT) IEC 60529.1989 Enclosure rating (IP code) IEC 61000-4-2.2008 Electromagnetic compatibility (EMC) part 4-2. Testing and measurement techniques - Electrostatic discharge immunity test

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 34142-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 34142-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 34142-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 34142-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.