US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34140-2017: Radiation protection instrumentation -- Highly sensitive hand-held instruments for neutron detection of radioactive material Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 34140-2017 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Radiation protection instrumentation -- Highly sensitive hand-held instruments for neutron detection of radioactive material
| Valid |
GB/T 34140-2017
|
PDF similar to GB/T 34140-2017
Basic data Standard ID | GB/T 34140-2017 (GB/T34140-2017) | Description (Translated English) | Radiation protection instrumentation -- Highly sensitive hand-held instruments for neutron detection of radioactive material | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | F84 | Classification of International Standard | 13.280 | Word Count Estimation | 22,255 | Date of Issue | 2017-07-31 | Date of Implementation | 2017-11-01 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 34140-2017: Radiation protection instrumentation -- Highly sensitive hand-held instruments for neutron detection of radioactive material ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Radiation protection instrumentation - Highly sensitive hand-held instruments for neutron detection of radioactive material
ICS 13.280
F84
National Standards of People's Republic of China
Radiation protection equipment for radioactive material neutrons
Detection of highly sensitive handheld instrument
Radiationprotectioninstrumentation-Highly sensitive and-heldinstruments
(IEC 62534.2010, IDT)
2017-07-31 Posted
2017-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
3.1 Overview 1
3.2 Definition 2
3.3 volume and unit 3
4 General requirements 3
4.1 General characteristics 3
4.2 Physical Structure 3
4.3 basic information 3
4.4 working mode 4
4.5 Maintenance/Calibration 4
4.6 Communication Interface 4
4.7 User Interface 4
4.8 logo 5
4.9 Power 5
4.10 switch protection 5
4.11 display unit 5
4.12 effective measuring range 5
4.13 alarm 6
4.14 Explosive air 6
4.15 Indicator Features 6
5 General test methods 6
5.1 Experimental nature 6
5.2 Reference conditions and standard test conditions 6
5.3 Statistics Fluctuation 6
6 radiation test 7
6.1 source prompt false alarm rate 7
6.2 source alarm and response time 7
6.3 Neutron Alarms in the Presence of Photons 7
6.4 Neutron alarm overload characteristics 8
6.5 Personal Protection Alarm 8
6.6 Preheat 8
7 Environmental, mechanical and electrical performance requirements 8
7.1 Temperature 8
7.2 Humidity 9
7.3 Cold start 9
7.4 Dust and waterproof test 9
7.5 Machinery 10
7.6 Collision (flutter) 11
7.7 Battery Requirements 11
7.8 Electrostatic discharge test 12
7.9 Radio Frequency (RF) 12
7.10 RF radiation emission 12
7.11 Conduct Harassment 12
7.12 Magnetic Field 13
8 file 13
8.1 Overview 13
8.2 Type Test Report 13
8.3 Certificate of Compliance 13
8.4 Operation and Maintenance Manual 14
References 15
Table 1 reference conditions and standard test conditions 14
Table 2 RF emission limits 14
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the translation method identical with IEC 62534.2010 "Radiation protection instrumentation for high sensitivity neutron detection of radioactive material
Handheld instrument. "
The documents of our country that have consistent correspondence with the international standards that are normative references in this standard are as follows.
--- GB/T 13161-2015 Radiation protection instrumentation for measuring X, γ, neutron and β radiation dose equivalent Hp (10) and
Hp (0.07) Direct Reading Personal Dose Equivalent (IEC 61526.2010, IDT);
Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test (IEC 61000-4-2).
2001, IDT).
This standard made the following editorial changes.
--- Table 1 "relative humidity" and "atmospheric pressure" footnote a to b.
This standard proposed by China National Nuclear Corporation.
This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized.
This standard was drafted unit.Nuclear Industrial Standardization Institute, Xiamen City, metrological testing institute, Xiamen Minya Zhongmin Electronic Technology Co., Ltd..
The main drafters of this standard. Zhang Jingchang, Liu Pingping, Zheng Peng, Guo Wenqiong.
Radiation protection equipment for radioactive material neutrons
Detection of highly sensitive handheld instrument
1 Scope
This standard applies to the detection and positioning of neutron emission of radioactive substances handheld devices. These highly sensitive instruments are designed primarily for the purpose
Used to detect subtle changes within the normal background caused by the illicit trafficking or unintentional transfer of radioactive material. Highly sensitive instruments allow
Scans large items, such as vehicles or containers. In order to monitor checkpoints or hazardous areas, these instruments are also allowed to be fixed or temporarily fixed
Set unattended use. The instruments specified in this standard also provide methods of detecting photon radiation for personal protection.
This standard does not apply to GB/T 14318-2008 and IEC 61526 radiation protection equipment involved in the performance.
The purpose of this standard is to establish performance requirements, provide examples of acceptable test methods and provide general characteristics, general test conditions, radiation
Characteristics, electrical safety and environmental conditions, used to determine whether the instrument meets the requirements of this standard.
The test results provide government agencies and other users with information on the ability of radiation detectors to reliably detect neutron sources.
Equipment to meet or exceed the technical requirements of this standard performance requirements depend on the correct establishment of appropriate working parameters, the implementation of school
Perform appropriate response testing and maintenance procedures, review conforming quality requirements, and provide formal training to operators.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2900.81-2008 Electrotechnical terminology Nuclear physics and basic concepts (IEC 60050-393.2003, IDT)
GB/T 2900.82-2008 Electrotechnical terminology Instruments Instruments, systems, equipment and detectors (IEC 60050-394.2007,
IDT)
GB/T 4208-2008 enclosure protection (IP code) (IEC 60529.2001, IDT)
GB/T 14055.1-2008 Neutron reference radiation - Part 1. Radiation characteristics and methods of production (ISO 8529-1.2001, IDT)
GB/T 14318-2008 Radiation protection instrumentation around the neutron dose equivalent (rate) instrument (IEC 61005.2003, IDT)
IEC 61000-4-2.2008 Electromagnetic compatibility (EMC) Part 4-2. Testing and measurement techniques Electrostatic discharge immunity test
[Electromagnetic compatibility (EMC) -Part 4-2. Testing and measurement techniques-
Electrostaticdischargeimmunitytest]
IEC 61526.2005 Radiation protection instrumentation measures individual doses equivalent X, gamma, neutron and beta radiation Hp (10) and Hp (0.07)
Reading personal dose equivalent meter
3 Terms and definitions
3.1 Overview
The following terms and definitions apply to this document.
NOTE Radiation levels and dosimetry terms are given in GB/T 2900.81-2008 and GB/T 2900.82-2008.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34140-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34140-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 34140-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34140-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|