US$759.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34119-2017: Railway applications -- Electrical connector for rolling stock Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 34119-2017 | English | 759 |
Add to Cart
|
6 days [Need to translate]
|
Railway applications -- Electrical connector for rolling stock
| Valid |
GB/T 34119-2017
|
PDF similar to GB/T 34119-2017
Basic data | Standard ID | GB/T 34119-2017 (GB/T34119-2017) | | Description (Translated English) | Railway applications -- Electrical connector for rolling stock | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | S35 | | Classification of International Standard | 45.060 | | Word Count Estimation | 38,361 | | Date of Issue | 2017-07-31 | | Date of Implementation | 2018-02-01 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 34119-2017: Railway applications -- Electrical connector for rolling stock---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Railway applications - Electrical connector for rolling stock
ICS 45.060
S35
National Standards of People's Republic of China
Rail transit locomotive vehicle electrical connector
2017-07-31 Posted
2018-02-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword V.
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 environmental conditions 6
4.1 normal environmental conditions 6
4.2 special environmental conditions 6
5 installation location classification 6
5.1 Overview 6
5.2 Locomotive and vehicle operating environment 6
5.3 locomotive vehicle electrical connector installation location 6
6 Technical Requirements 8
6.1 Overview 8
6.2 Identification and marking 8
6.3 The minimum severity of the installation location 8
6.4 Appearance and Dimensions, Structure and Parts Requirements 9
6.5 Interchangeability 10
6.6 Electrical Connector Connection Positioning and Mis-insertion Protection 10
6.7 Rated current 10
6.8 Contact Resistance 11
6.9 Insulation resistance 13
6.10 Dielectric strength 13
6.11 Contact Fixation 13
6.12 insulation mounting plate fixed 14
6.13 cable stress relief 14
6.14 Tensile strength 15
6.15 Connection Force 15
6.16 Free Connector Performance 17
6.17 Mechanical Durability 17
6.18 Temperature Range and Temperature Rise 17
6.19 low temperature 18
6.20 high temperature 18
6.21 Flow mixed gas corrosion 18
6.22 salt spray corrosion 18
6.23 temperature change 18
6.24 alternating hot and humid 18
6.25 protection class 18
6.26 Ground Protection 18
6.27 Shock and vibration 19
6.28 liquid impregnation 19
6.29 Electromagnetic compatibility 19
6.30 Raw material requirements 19
7 test methods 19
7.1 General 19
7.2 appearance and size check 20
7.3 Marking Durability Inspection 20
7.4 Interchangeability check 21
7.5 connector connector positioning and wrong insertion protection test 21
7.6 Contact resistance test 21
7.7 Insulation resistance test 21
7.8 Dielectric strength test 22
7.9 Contact fixing test 22
7.10 insulation mounting plate fixation test 22
7.11 Cable Tension Endurance Test 22
7.12 Cable clip distortion endurance test 22
7.13 Cable clamp bending endurance test 22
7.14 Tensile strength test 23
7.15 Connection test 23
7.16 Impact test 23
7.17 Mechanical Durability Tests 24
7.18 temperature rise test 24
7.19 low temperature test 24
7.20 high temperature test 24
7.21 Flow mixed gas corrosion test 24
7.22 salt spray corrosion test 24
7.23 temperature change test 24
7.24 alternating hot and humid test 25
7.25 Degree of protection test 25
7.26 Ground Resistance Measurement 25
7.27 Shock and vibration test 25
7.28 liquid immersion test 25
7.29 Electromagnetic compatibility test 26
7.30 Raw material test 26
Inspection rules 27
8.1 Test classification 27
8.2 factory inspection 27
8.3 type test 27
8.4 inspection items 28
9 Packaging, transport and storage 29
9.1 Packaging 29
9.2 Transportation and storage 29
Appendix A (informative) Additional features and test information 30
References 32
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Please note that some of this document may be patentable. The issuing agencies of this document do not bear the responsibility of identifying these patents.
This standard proposed by the National Railway Administration.
This standard by the National Traction Electrical Equipment and Systems Standardization Technical Committee (SAC/TC278) centralized.
This standard is drafted by CNR Zhuzhou Electric Locomotive Research Institute Co., Ltd.
Participated in the drafting of this standard. Zhuzhou Electric Locomotive Co., Ltd., Qishuyan Locomotive Co., Ltd., Qingdao Sifang vehicles
Institute Co., Ltd., CTS Qingdao Sifang Locomotive Co., Ltd.
The main drafters of this standard. Shao Zhi and Yan Yun Sheng, Ma Xiaoning, Chen Jianhua, 昝 Haibin, Yin Shouzhi, Wang Qiuhua.
Rail transit locomotive vehicle electrical connector
1 Scope
This standard specifies the locomotive vehicle electrical connector environmental conditions, installation location classification, technical requirements, test methods, inspection rules, package
Loading, transportation and storage.
This standard applies to the rated voltage not higher than 1000V, a single contact current rating is not greater than 600A and the operating frequency is not greater than
3MHz single-core or multi-core electrical connectors, and operating frequency of not more than 100MHz communications connector. Other specifications of the locomotive
Electric connector, can refer to this standard.
This standard does not apply to the following types of electrical connectors.
--- Breaking capacity of the electrical connector.
Note 1. For safety, the locomotive vehicle electrical connector is not energized (eg plugged in, unplugged) nor operated by means of operating procedures or interlocking.
--- Automatic coupler electrical connector.
Note 2. The mechanical structure attached to the automatic coupler electrical connector is more complicated and is not within the scope of this standard.
--- Workshop jumper.
Note 3. Workshop jumpers are assembled from electrical connectors and cables. The scope of this standard covers only electrical connectors and can not cover shop jumpers.
Electrical connectors within the electronics, such as printed circuit boards, chassis and panel electrical connectors.
--- By spring pressure contact connectors to implement the electrical connector.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature (IEC 60068-2-
1.2007, IDT)
GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature (IEC 60068-2-
2.2007, IDT)
GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Db. Alternating hot and humid (12h
12h cycle) (IEC 60068-2-30.2005, IDT)
GB/T 2423.17-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Ka. Salt spray (IEC 60068-2-
11.1981, IDT)
GB/T 2423.22-2012 Environmental testing Part 2. Test methods Test N. Temperature changes (IEC 60068-2-4.2009,
IDT)
GB/T 2828.1-2012 Sampling procedures for inspection - Part 1 - Batch-by-lot inspection by acceptance quality limit (AQL)
Plan (ISO 2859-1.1999, IDT)
GB/T 4208-2008 enclosure protection (IP code) (IEC 60529.2001, IDT)
GB/T 4210 Electrotechnical terminology electromechanical components for electronic equipment (GB/T 4210-2015, IEC 60050-581.2008, IDT]
GB/T 4776 electrical safety terminology
GB/T 5095.2-1997 Electromechanical components for electronic equipment - Basic test procedures and measurement methods - Part 2. General inspection, electrical
Continuity and contact resistance test, insulation test and voltage stress test (idtIEC 60512-2.1985)
GB/T 5095.3-1997 Electromechanical components for electronic equipment Basic test procedures and measurement methods Part 3. Current carrying capacity test
Test (idtIEC 60512-3.1976)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34119-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34119-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 34119-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34119-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|