US$279.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 33868-2017: Calibration method for ultraviolet radiometer Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 33868-2017 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Calibration method for ultraviolet radiometer
| Valid |
GB/T 33868-2017
|
PDF similar to GB/T 33868-2017
Basic data Standard ID | GB/T 33868-2017 (GB/T33868-2017) | Description (Translated English) | Calibration method for ultraviolet radiometer | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | A47 | Classification of International Standard | 07.060 | Word Count Estimation | 14,181 | Date of Issue | 2017-07-12 | Date of Implementation | 2018-02-01 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 33868-2017: Calibration method for ultraviolet radiometer---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration method for ultraviolet radiometer
ICS 07.060
A47
National Standards of People's Republic of China
Calibration method of ultraviolet radiation table
2017-07-12 released
2018-02-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface I
1 Scope 1
2 terms and definitions
3 Calibration conditions 1
4 calibration method 2
5 Uncertainty assessment of calibration results
6 calibration results 3
7 re - school time interval 3
Appendix A (Normative Appendix) Spectral Radiometer Specifications 4
Appendix B (normative) Spectral radiometer method 5
Appendix C (informative) Evaluation Method for Uncertainty of Calibration Results of Ultraviolet Radiation Table 7
Reference 10
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by the China Meteorological Administration.
This standard is nationalized by the National Standardization Technical Committee for Meteorological Instruments and Observation Methods (SAC/TC507).
The drafting unit of this standard. National Meteorological Metering Station, Jiangsu Radio Science Research Institute Co., Ltd.
The main drafters of this standard. Ding Lei, Yang Yun, Quan Jimei, Chong Wei, Xu Yigang, Gu Ping month.
Calibration method of ultraviolet radiation table
1 Scope
This standard specifies the calibration conditions for the UV radiation table, the calibration method, and the uncertainty of the calibration results.
This standard applies to the solar broadband UV radiation table sensitivity calibration.
2 terms and definitions
The following terms and definitions apply to this document.
2.1
Ultraviolet radiation table
Broadband ultraviolet radiation table broadbandultra ultravioletradiometer
Bandwidth greater than tens of nanometers, measuring ground ultraviolet ultraviolet radiation (UV) instruments.
Note. According to the measurement of the spectral range can be divided into three categories. measuring UV-A (315nm ~ 400nm), UV-B (280nm ~ 315nm) or UV-AB
(280nm ~ 400nm) broadband ultraviolet radiation table.
3 calibration conditions
3.1 Environmental conditions
3.1.1 around the open, the instrument sensor surface above no obstacles.
3.1.2 Sky clear, good atmospheric transparency, the sun height angle of not less than 30 °.
3.1.3 air temperature in the range of 10 ℃ ~ 30 ℃, the relative humidity of not more than 80%, wind speed is not greater than 5m/s.
3.2 standard and ancillary equipment
3.2.1 Standard Broadband Ultraviolet Radiation Table
Should meet the following requirements.
a) The uncertainty should not be greater than 7%;
b) cosine response error (zenith angle 0 ° ~ 70 °) should not be greater than 2.5%;
c) Outside response (greater than 400nm) should not exceed 0.1%.
3.2.2 digital instrumentation
0.05, resolution 1μV.
3.2.3 Environmental measuring instruments
Technical indicators in Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 33868-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 33868-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 33868-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 33868-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|