US$139.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 33672-2017: Cavity Ring-Down Spectroscopy system for measurement of atmospheric methane Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 33672-2017 | English | 139 |
Add to Cart
|
3 days [Need to translate]
|
Cavity Ring-Down Spectroscopy system for measurement of atmospheric methane
| Valid |
GB/T 33672-2017
|
PDF similar to GB/T 33672-2017
Basic data Standard ID | GB/T 33672-2017 (GB/T33672-2017) | Description (Translated English) | Cavity Ring-Down Spectroscopy system for measurement of atmospheric methane | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | A47 | Classification of International Standard | 07.060 | Word Count Estimation | 7,758 | Date of Issue | 2017-05-12 | Date of Implementation | 2017-12-01 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the working principle, composition, function, technical requirements and installation environment requirements of the optical cavity decay spectroscopy system for observing atmospheric methane concentration. This standard is suitable for atmospheric cavity methane optical cavity ring attenuation spectrum observation, also applies to the observation system design, processing and so on. |
GB/T 33672-2017: Cavity Ring-Down Spectroscopy system for measurement of atmospheric methane---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cavity Ring-Down Spectroscopy system for measurement of atmospheric
ICS 07.060
A47
National Standards of People's Republic of China
Atmospheric Methane Optical Cavity Attenuation Spectral Observation System
2017-05-12 released
2017-12-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
This standard is proposed by the China Meteorological Administration.
This standard by the National Climate and Climate Change Standardization Technical Committee of Atmospheric Component Observation and Forecasting Service Subcommittee
(SAC/TC540/SC1).
The drafting of this standard. China Meteorological Bureau Meteorological Survey Center, China Meteorological Science Research Institute.
The main drafters of this standard. Fang Shuangxi, Liang Miao, Liu Lixin, Yao Bo, Xia Lingjun, Wang Hongyang, Pan Jingjing, Li Geng, Xu Lina, Chen Liqu.
Atmospheric Methane Optical Cavity Attenuation Spectral Observation System
1 Scope
This standard specifies the working principle, composition and function of the optical cavity decay spectroscopy observation system for observing the atmospheric methane concentration. The technical requirements
And installation environment requirements.
This standard is applicable to atmospheric cavity methane optical cavity ring attenuation spectroscopy observation, also applies to the observation system design, processing and so on.
2 terms and definitions
The following terms and definitions apply to this document.
2.1
CavityRing-DownSpectroscopymethod; CRDS
A beam of single-wavelength laser into the cavity, the beam back and forth between the mirror reflection. When the light source is cut off, its energy will decay with time,
The rate of attenuation is related to the loss of the optical cavity itself (including transmission, scattering) and absorption of the intracavitary medium. According to the speed of light energy attenuation
The method of the content of the component to be tested.
2.2
Standard gas standardgas
To dry clean air for the gas, the target substance concentration known mixed gas.
Note. rewrite from QX/T 125-2011, define 10.2.
2.3
Work standard standard workingstandardgas
The standard gas used to quantitatively measure the concentration of the target substance in the sample.
Note. rewrite from QX/T 125-2011, defined 10.8.
2.4
Target standard targetstandardgas
Used to check and evaluate the operating conditions of the measurement system and are treated as regular and repeated measurements of the sample gas.
Note. rewrite from QX/T 125-2011, define 10.9.
2.5
Sample gas samplegas
The gas is measured by the measuring system.
3 working principle
The sample collection and processing unit draws the air from the sampling line, and after the temperature balance, pressure control, drying and other treatment, by the air/standard gas
Select the unit to select the sample gas or standard gas into the optical cavity to ring the host unit measurement, the relevant data stored in the data acquisition and processing unit. according to
The different responses of the system to air/standard gas can quantify the target substance concentration in the sample. The target substance content is determined according to formula (1).
χ =
Total =
NAPV
RT
RT
NAPV
· 1
c · σ (υ)
· 1
τυ () -
τempty
÷ (1)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 33672-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 33672-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 33672-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 33672-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|