|
US$619.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32518.1-2016: Field test code of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 32518.1-2016 | English | 619 |
Add to Cart
|
6 days [Need to translate]
|
Field test code of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor
| Valid |
GB/T 32518.1-2016
|
PDF similar to GB/T 32518.1-2016
Basic data | Standard ID | GB/T 32518.1-2016 (GB/T32518.1-2016) | | Description (Translated English) | Field test code of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K44 | | Classification of International Standard | 29.240.01 | | Word Count Estimation | 31,393 | | Date of Issue | 2016-02-24 | | Date of Implementation | 2016-09-01 | | Regulation (derived from) | National Standard Announcement No | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 32518.1-2016: Field test code of controlled shunt reactor of extra high voltage -- Part 1: Multistage controlled shunt reactor ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Field test code of controlled shunt reactor of extra high voltage - Part 1. Multistage controlled shunt reactor
ICS 29.240.01
K44
National Standards of People's Republic of China
EHV Controllable Shunt Reactor Field Test
Technical specifications - Part 1. Classification adjustable
Part 1. Multistagecontroledshuntreactor
Issued on. 2016-02-24
2016-09-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
CONTENTS
Preface Ⅰ ...
1 Scope 1 ...
2 Normative references 1 ...
3 Terms and definitions ...
4 Test equipment and subsystems 2 ...
5 System Test 15 ...
6 Commissioning 25 ...
Appendix A (informative) adjusted grade controllable shunt reactor works 26 ...
Foreword
GB/T 32518 is expected to be divided into two parts.
--- Part 1. Classification adjustable;
--- Part 2. magnetron.
This section GB/T Part of 132,518.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section is proposed and managed by the China Electricity Council.
This section is drafted. Smart Grid Research Institute of State Grid, China Electric Power Research Institute, the State Grid Corporation of China Northwest Division, State Grid Electric Power Research Institute in Gansu province electric power company, State Grid Electric Power Research Institute of Qinghai Electric Power Company, State Grid Hubei provincial power company Electric power Research Institute,
State Grid Electric Power Research Institute of Zhejiang Electric Power Corporation, China Southern Power Grid EHV transmission company overhaul testing center, China Power Engineering, Northwest Electric Power Design Institute, State Nuclear Electric Power Planning Design and Research Institute Consulting Group, China Power Engineering Consulting Group in North China Power Engineering Ltd, China power Engineering Consulting Group Southwest Electric power Design Institute.
This part drafters. Jia with Mao, Zhang ring, Zheng Bin, class even heptyl, Qin Rui, thanks Yun Qing, Mary Hill, healthy, high-grand, Kang Peng, Liyun Wei, Zhang Jianping, Wu Yi Qiong Lu Jin Zhuang, Bi Sheng, Tang Jinkun, Xia Zhonghui, Zoujia Yong, Zhu Dapeng.
EHV Controllable Shunt Reactor Field Test
Technical specifications - Part 1. Classification adjustable
1 Scope
GB/T 32518 provisions of this part of the UHP grade adjustable controllable shunt reactor field test items, test content, evaluation criteria.
This section applies to new or renovation and expansion of 500kV, 750kV EHV Transmission Project and the bus line installation adjusted grade controllable shunt reactor test site, other voltage levels adjusted grade controllable shunt reactors can be implemented by reference.
2 Normative references
The following documents for the application of this document is essential. For cited documents with dates, only the dated edition applies to this document. For undated references, the latest edition (including any amendments) applies to this document.
GB 1094.2 Power transformers - Part 2. Temperature Rise
GB 1094.3 Power transformers Part 3. Insulation levels, dielectric tests and external insulation air gap
GB/T 2900.15 Electrotechnical terminology transformers, transformers, regulators and reactors
GB/T 2900.17 Electrotechnical terminology measuring relays
GB/T 2900.49 Electrotechnical terminology - Power System Protection
GB 50150-2006 works of electrical installations electrical equipment handover test standard
DL/T 995-2006 relay protection and automatic device grid security inspection procedures
DL/T 1193-2012 term FACTS
3 Terms and Definitions
GB/T 2900.15, GB/T 2900.17, GB/T 2900.49 and DL/T 1193-2012 and defined the following terms and definitions apply to this document.
3.1
controled shunt reactor (CSR)
Parallel connection system, a reactance change in online reactors, including continuous adjustment and classification adjustment in two ways, mainly by the body (for the transformer-type controllable shunt reactors high-impedance transformer), valve system, auxiliary equipment protection and control systems and other components, usually installed in line or bus.
3.2
transformer type controled shunt reactor (TTCSR)
By changing the controllable reactor to achieve a low pressure side equivalent impedance reactance value changes controllable shunt reactor.
3.3
multistage controled shunt reactor
Impedance can only switch controllable shunt reactor between a finite number of levels.
Note. The adjusted grade controllable shunt reactors basic principles in Appendix A.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32518.1-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32518.1-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32518.1-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32518.1-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|