US$379.00 ยท In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 32503.1-2016: Household and similar adjustable frequency converter safety -- Part 1: General requirements Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 32503.1-2016 | English | 379 |
Add to Cart
|
4 days [Need to translate]
|
Household and similar adjustable frequency converter safety -- Part 1: General requirements
| Valid |
GB/T 32503.1-2016
|
PDF similar to GB/T 32503.1-2016
Basic data | Standard ID | GB/T 32503.1-2016 (GB/T32503.1-2016) | | Description (Translated English) | Household and similar adjustable frequency converter safety -- Part 1: General requirements | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K32 | | Classification of International Standard | 97.120 | | Word Count Estimation | 19,120 | | Date of Issue | 2016-02-24 | | Date of Implementation | 2016-09-01 | | Regulation (derived from) | National Standard Announcement No | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 32503.1-2016: Household and similar adjustable frequency converter safety -- Part 1: General requirements ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Household and similar noise frequency converter safety - Part 1. General requirements
ICS 97.120
K32
National Standards of People's Republic of China
Household and similar use frequency converter
Safety - Part 1. General requirements
Part 1. Generalrequirements
2016-02-24 released
2016-09-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Directory
Preface I
1 Scope 1
2 normative reference document 1
3 Definition 2
4 General requirements 3
5 General description of the test 3
6 Rating 4
Category 4
8 Information 4
9 protection against electric shock 5
10 Earthing protection measures 5
11 terminals and terminals 5
Structural Requirements
13 moisture and dust 7
Electrical strength and insulation resistance
15 fever 7
Manufacturing Deviation and Drift 7
Environmental stress 7
18 empty chapter 8
19 mechanical strength 8
20 Threaded parts and connections
21 Electrical clearance, creepage distance and solid insulation
22 heat resistance, fire resistance and resistance to tracking 8
23 Corrosion resistance 8
24 Electromagnetic Compatibility (EMC) Requirements - Launch 8
25 empty chapter 8
26 normal operation 8
27 Electromagnetic compatibility (EMC) requirements - immunity 9
28 Abnormal operation 9
Appendix A (informative) Software protection for typical faults of frequency converter 12
Appendix B (informative) Thermal test method for power modules
Foreword
GB/T 32503 "Safety of household and similar frequency conversion controllers", divided into the following two parts.
- Part 1. General requirements;
Part 2. Special requirements.
The special requirements are made up of the following.
Safety of household and similar frequency converters - Part 2-1. Particulars for frequency converters for heat pumps, air conditioners and dehumidifiers
Claim;
This part is part 1 of GB 32503.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part is made by China Electrical Equipment Industry Association.
This part is headed by the National Standardization Technical Committee for Home Automation (SAC/TC212).
This part of the drafting unit. China Electrical Appliances Research Institute Co., Ltd., Guangdong University of Technology, Guangdong, the United States Refrigeration Equipment Co., Ltd., Hisense
(Shandong) Air Conditioning Co., Ltd., China Household Electrical Appliances Research Institute, Guangdong Kelon Air Conditioner Co., Ltd., Guangdong South China Home Appliances Research Institute, Boshi Huadian
(Jiangsu) Co., Ltd., Zhuhai Gree Electric Co., Ltd., Qingdao Haier Air Conditioner Co., Ltd., Daikin (China) Investment Co., Ltd.,
Nanjing Byron Technology Co., Ltd., Zhejiang Shield Artificial Environment Co., Ltd., Shanghai Hitachi Electric Co., Ltd., Zhejiang Sanhua Co., Ltd.
Company, TCL air conditioner (Zhongshan) Co., Ltd., Qingdao three source Tyco Electronic Technology Co., Ltd., Jiangsu snow Electric Co., Ltd., deep
Shenzhen Topen Co., Ltd., Zhuhai Lingda Compressor Co., Ltd., Jiaxi Bella Compressor Co., Ltd., Guangzhou Wanbao Group Compressor Co., Ltd.
Company, Foshan City, Granville Electronics Co., Ltd., Anhui Meizhi Refrigeration Equipment Co., Ltd., Lanxi City, the stronger Electric Co., Ltd., Wuxi Little Swan
Co., Ltd., Sichuan Changhong Electric Co., Ltd.
This part of the drafters. Wang Zhigang, Yu Yongquan, Zheng Xucheng, Yin Xianxin, Kong Ruixun, Jia Yulin, Sun Yingkai, Xie Jianfei, Dai Fang, Li Wencan,
Wang Youning, Zhang Jianjiang, Pan Bangyan, Wang Xiangrong, Wang Hui, Ye Rong, Zhu Jiuchang, Lin Zhiqiang,
XU Lin, YAN Zhi-qi, ZHU Xiao-ying, WANG Wei-jie, LI Zhao-yi, JI Xue-nong, WANG Bin, ZHONG Ming
Household and similar use frequency converter
Safety - Part 1. General requirements
1 Scope
This part of GB/T 32503 specifies the safety of frequency conversion controllers in household and similar equipment, including for use in household or similar
Use of refrigerators, air conditioners, electric fans, washing machines, dishwashers, vacuum cleaners, heat pump water heaters and similar applications with output power greater than 10W
, And the maximum rated voltage does not exceed 690V, the maximum rated current does not exceed 63A (these parameters are the controller) for the control of the motor
Variable frequency controller (referred to as. frequency controller).
This section applies to the inherent safety of the frequency converter installed in the equipment in a household or similar equipment and is suitable for use with equipment
Safety-related operating values, operating time and operating procedures, as well as for applications that are used in conjunction with the device in a household or similar equipment
Safety test of automatic control device for frequency controller.
This section applies to the frequency converter used in the equipment and equipment within the scope of GB 4706.1.
Not as a general appliance, but for public places, such as equipment and equipment used by shops, light industry and farms by non-professionals,
The variable frequency controller is also in the scope of this part.
This part does not apply to frequency control controllers and hand-held power tools for industrial purposes, children's vehicles, disabled cars, electric motorcycles
Cars and other use of the inverter controller.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 2423.10-2008 Environmental testing for electric and electronic products - Part 2. Test methods - Test Fc. Vibration (sinusoidal)
(IEC 60068-2-6..1995, IDT)
GB/T 2900.1-2008 Basic terminology for electrical terminology (IEC 60050-101-1998, NEQ)
GB/T 2900.25-2008 Electrotechnical terms Rotating electrical machines (IEC 60050-411..1996, IDT)
Electrotechnical terminology - Power semiconductor devices GB/T 2900.32-1994
GB 4343.1-2009 Electromagnetic compatibility requirements for household appliances, power tools and similar appliances - Part 1. Launch (IEC /CISPR
14-1..2005, IDT)
GB 4343.2-2009 Electromagnetic compatibility requirements for household appliances, power tools and similar appliances - Part 2. Immunity
(IEC CISPR14-2..2008, IDT)
GB 4706.1-2005 Safety of household and similar electrical appliances - Part 1. General requirements [IEC 60335-1..2004
(Ed4.1), IDT]
GB 4706.32-2012 Safety of household and similar electrical appliances - Particular requirements for heat pumps, air conditioners and dehumidifiers (IEC 60335-
2-40..2005, IDT)
GB 9364.1 Miniature fuses - Part 1. Definitions of small fuses and general requirements for small fuse - links (GB 9364.1-1997,
IEC 60127-1. 1988, IDT)
GB/T 14472-1998 Fixed capacitors for use in electronic equipment - Part 14. Sectional specification - Fixed capacitors for electromagnetic interference
(IEC 60384-14..1993, IDT)
GB 14536.1-2008 Automatic control for household and similar use - Part 1. General requirements (IEC 60730-1..2003,
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 32503.1-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 32503.1-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 32503.1-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 32503.1-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|