US$379.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31459-2015: Safety requirements for temperature control systems for floor heating for household and similar use Status: Valid GB/T 31459: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 31459-2015 | English | 379 |
Add to Cart
|
4 days [Need to translate]
|
Safety requirements for temperature control systems for floor heating for household and similar use
| Valid |
GB/T 31459-2015
|
GB/T 31459-2015 | English | 379 |
Add to Cart
|
4 days [Need to translate]
|
Safety requirements for temperature control systems for floor heating for household and similar use
| Valid |
GB/T 31459-2015
|
PDF similar to GB/T 31459-2015
Basic data Standard ID | GB/T 31459-2015 (GB/T31459-2015) | Description (Translated English) | Safety requirements for temperature control systems for floor heating for household and similar use | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K32 | Classification of International Standard | 97.120 | Word Count Estimation | 18,184 | Date of Issue | 2015-05-15 | Date of Implementation | 2016-06-01 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 31459-2015: Safety requirements for temperature control systems for floor heating for household and similar use ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety requirements for temperature control systems for floor heating for household and similar use
ICS 97.120
K32
National Standards of People's Republic of China
GB 31459-2015
Household and similar purpose floor heating equipment temperature
Control system safety requirements
2015-05-15 released
2016-06-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Test General Description 2
5 rating 3
6 Categories 4
7 information 4
8 functional safety requirements 5
9 anti-shock protection 6
Grounding protection measures 6
11 terminal and terminal 7
12 structural requirements 7
13 moisture and dust 7
Electrical strength and insulation resistance 8
15 fever 8
16 manufacturing deviation 8
Environmental Stress 9
Durability 10
19 Mechanical strength 10
20 Creepage distance, clearance and distance through solid insulation 11
21 heat, fire and tracking marks 11
Corrosion resistance 11
23 Electromagnetic Compatibility (EMC) Requirements 11
24 components 11
Electronic Controller Requirements 11
Appendix A (Informative) Floor heating equipment with temperature control system wiring diagram 12
GB 31459-2015
Foreword
The technical content of this standard is mandatory.
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard proposed by the China Electrical Equipment Industry Association.
This standard by the National Automatic Control Standardization Technical Committee (SAC/TC212) centralized.
This standard was drafted unit. China Electric Apparatus Research Institute Co., Ltd., Man Ruide automatic control system (Yueqing) Co., Ltd., Zhejiang Dunan artificial
Environmental Co., Ltd., Ningbo City, Europe know Electric Technology Co., Ltd., Ningbo Branch IC Design Center Co., Ltd., Daikin (China)
Investment Co., Ltd. Shanghai Branch, Ningbo Beilun Haibo Exquisite Machinery Manufacturing Co., Ltd., Shenzhen Topband Co., Ltd., Zhuhai Gree
Electrical Co., Ltd., Jiangsu Chang Heng Group Automation Co., Ltd., Hisense Kelon Electrical Co., Ltd., Guangdong Exit Inspection
Quarantine Inspection and Quarantine Technology Center, Wei Kai Detection Technology Co., Ltd.
The main drafters of this standard. Lin Yongming, Chen Linan, Wang Xiangrong, Ke Ci Long, Huang Chao, Zhang Jianqiang, He Dingfang, Li Zhi, Fan Lingyun, Du Li, Luo
Hui, Feng Da, Qian Feng.
GB 31459-2015
Introduction
Household and similar purpose floor heating equipment with temperature control system is widely used in hot water as a heat medium or heating cable, electric film plus
Thermal components of the radiant heating system engineering used to control the electric valve, electric valve, electric valve and heating equipment and other equipment temperature control and display
System is involved in product safety, energy saving and environmental protection of the key components, for pressure, cold and anti-corrosion, etc. have higher requirements.
This standard provides the basis for the safety and performance evaluation of the temperature control system for home and similar floor heating equipment, to the industry
Designers provide a reference design and exchange platform, so that the safety of end-product design more standardized.
GB 31459-2015
Household and similar purpose floor heating equipment temperature
Control system safety requirements
1 Scope
This standard specifies the mechanical, electronic household and similar purpose floor heating equipment with temperature control system safety requirements. This standard includes
The requirements for controlling the temperature control system in the home are also included with the pipeline pump, water heater, central air conditioning system and building automation system
Supporting the use of floor heating temperature control system requirements, but also includes a remote control and intelligent control of floor heating temperature control system requirements. this
The standard does not include the requirements of the radiant part of the floor heating.
This standard applies to the rated voltage does not exceed 690V, the rated current does not exceed 63A, on the room by the electrical energy into heat (often called electricity
Floor heating) or through the hot fluid medium to spread heat (often called warm water), requiring a single or dual temperature control floor warm temperature control system.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature
GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature
GB/T 2423.3 Environmental testing for electric and electronic products Part 2. Test methods Test Cab. Constant hot and humid
GB/T 2423.22 Environmental testing for electric and electronic products Part 2. Test methods Test N. Temperature changes
GB 4208 enclosure protection (IP code)
GB 4343.1-2009 Household appliances, power tools and similar appliances - EMC requirements Part 1. Emission
GB 4343.2-2009 Household appliances, power tools and similar appliances EMC requirements Part 2. Immunity
Automatic electrical controls for household and similar use - Part 1. General requirements
GB 14536.10-2008 Household and similar electrical automatic controlgear Particular requirements for temperature-sensitive controller
IEC 60536 classification of electric and electronic equipment protection against electric shock (Classificationofelectricalandelectronicequipment
withregardrotectionagainstelectricshock)
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Warm floorheating
Using hot water or electric power as a heating medium or a heat source, heat conduction means such as a heating pipe or an electric heating device embedded in the floor of a building is used to conduct heat
Way to heat the ground, the surface to radiation and convection heat transfer to the indoor heating mode of heating.
3.2
Water warm waterfloorheating
Also known as low-temperature hot water radiant floor heating. To the temperature is not higher than 60 ℃ hot water as heat medium, circulating in the heating pipe to heat the ground
Heating method.
GB 31459-2015
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31459-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 31459-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 31459-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31459-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 31459-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 31459-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|