|
US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31010-2014: Spectral calibration in laboratory for dispersive hyperspectral sensor Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 31010-2014 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Spectral calibration in laboratory for dispersive hyperspectral sensor
| Valid |
GB/T 31010-2014
|
PDF similar to GB/T 31010-2014
Basic data | Standard ID | GB/T 31010-2014 (GB/T31010-2014) | | Description (Translated English) | Spectral calibration in laboratory for dispersive hyperspectral sensor | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N30 | | Classification of International Standard | 17.180.01 | | Word Count Estimation | 9,930 | | Date of Issue | 9/3/2014 | | Date of Implementation | 2/1/2015 | | Quoted Standard | GJB 2700-1996; GJB 3007A-2009 | | Regulation (derived from) | People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the dispersive spectroscopy hyperspectral remote sensor calibration laboratory equipment conditions and experimental methods. This Standard applies to working band of 0.4��m ~ 2.5��m dispersion imaging type (such as filter type, type |
GB/T 31010-2014: Spectral calibration in laboratory for dispersive hyperspectral sensor---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Spectral calibration in laboratory for dispersive hyperspectral sensor
ICS 17.180.01
N30
National Standards of People's Republic of China
Dispersive spectroscopy Hyperspectral Sensor Calibration Laboratory
Issued on. 2014-09-03
2015-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard was proposed by the Chinese Academy of Sciences.
This standard by the National Remote Sensing Technology Standardization Technical Committee (SAC/TC327) centralized.
This standard was drafted. Institute of Physics, Changchun Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Anhui Optics and Fine Mechanics Research
The Chinese Academy of Sciences Shanghai Institute of Technical Physics.
The main drafters of this standard. Yanchang Xiang, Shaojian Bing, Zheng Xiaobing, Ma Yanhua.
Dispersive spectroscopy Hyperspectral Sensor Calibration Laboratory
1 Scope
This standard specifies the dispersive spectroscopy hyperspectral remote sensor calibration laboratory equipment conditions and experimental methods.
This standard applies to working band is 0.4μm ~ 2.5μm dispersion imaging type (such as filter type, type diffraction grating, prism dispersive)
Airborne/spaceborne hyperspectral remote sensor spectral calibration laboratories. Other dispersive spectral remote sensor calibration laboratories can use the reference.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GJB2700-1996 Satellite Terminology
GJB3007A-2009 anti-static work area technical requirements
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Hyperspectral Sensor hyperspectralremotesensor
10-2λ spectral resolution in the order of optical remote sensor, λ is the operating wavelength.
3.2
Spectral calibration spectralcalibration
Hyperspectral Sensor determination process for each channel spectrum peak wavelength and spectral bandwidth.
3.3
Laboratory spectral calibration laboratoryspectralcalibration
Spectroscopy in the laboratory to conduct hyperspectral remote sensor calibration.
3.4
Spectral bandwidth spectralbandwidth
Hyperspectral Sensor for each spectral channel relative spectral response curve, the spectral response is maximum corresponding to half the difference between the wavelengths.
4 General requirements
4.1 Calibration Laboratory
Calibration laboratory environmental conditions are as follows.
a) the level of cleanliness should be better than one hundred thousand. TBD elevation spectral remote sensor for cleanliness have special requirements, they should be required to perform;
b) In the remote sensor working band and the field of view to suppress stray light;
c) a temperature of 20 ℃ ± 3 ℃, relative humidity of 50% ± 10%. TBD elevation spectral remote sensor for temperature and humidity have special requirements, should be
Requests the Executive;
d) should have good anti-static condition, anti-static work area should be consistent with the relevant provisions of GJB3007A-2009.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31010-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 31010-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 31010-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31010-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|