US$4874.00 · In stock Delivery: <= 10 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30268.1-2013: Information technology -- Conformance testing for the biometric application programming interface (BioAPI) -- Part 1: Methods and procedures Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30268.1-2013 | English | 4874 |
Add to Cart
|
10 days [Need to translate]
|
Information technology -- Conformance testing for the biometric application programming interface (BioAPI) -- Part 1: Methods and procedures
| Valid |
GB/T 30268.1-2013
|
PDF similar to GB/T 30268.1-2013
Basic data | Standard ID | GB/T 30268.1-2013 (GB/T30268.1-2013) | | Description (Translated English) | Information technology -- Conformance testing for the biometric application programming interface (BioAPI) -- Part 1: Methods and procedures | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L71 | | Classification of International Standard | 35.040 | | Word Count Estimation | 244,231 | | Quoted Standard | GB 13000-2010; ISO/IEC 19784-1 | | Adopted Standard | ISO/IEC 24709-1-2007, IDT | | Regulation (derived from) | National Standards Bulletin 2013 No. 27 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the concepts, frameworks, test methods and criteria. Also provides BioAPI conformance test suite using the guide, write and test assertions compliance testing process to be followed in order. This standard focuses on conformance te |
GB/T 30268.1-2013: Information technology -- Conformance testing for the biometric application programming interface (BioAPI) -- Part 1: Methods and procedures ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Information technology Conformance testing for the biometric application programming interface (BioAPI) Part 1. Methods and procedures
ICS 35.040
L71
National Standards of People's Republic of China
Information technology - Biometric application program interface
(BioAPI) compliance testing
Part 1. Methods and procedures
programminginterface (BioAPI) -
Part 1. Methodsandprocedures
(ISO /IEC 24709-1.2007, IDT)
Issued on. 2013-11-11
2014-07-15 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Compliance 1
3 Normative references 1
4 Terms and definitions 2
5 Acronyms 3
6 Conformance Test Method 4
General Properties assertion language 12 7
8 of 17 elements assertion language
9 standard interface function 42
10 built-in variables 181
11 test log 189
12 Test Report 190
13 BioAPI conformance test suite 191
XML Schema in Appendix A (normative) assertion language 193
ASN.1 schema Appendix B (normative) assertion language 199
Appendix C (Normative Appendix) XML Schema test log 204
Annex D (informative) Test Method 207 Implementation Guide
Appendix E (Informative Appendix) BioAPI conformity assessment outline 212
Annex F (informative) assertion language XML icon 216
References 238
Foreword
GB/T 30268 "Information technology - Biometric application programming interface (BioAPI) compliance testing" is divided into the following four parts.
--- Part 1. Methods and procedures;
--- Part 2. Test biometric service providers assertion;
--- Part 3. Test assertions BioAPI framework;
--- Part 4. biometric application test assertions.
This section GB/T Part of 130,268.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with the international standard ISO /IEC 24709-1.2007 "Information technology - Biometric application
Interface (BioAPI) compliance testing - Part 1. Methods and procedures. "
This section also made the following editorial changes. In Chapter 3, the inclusion in the ISO /IEC 24709-1.2007 7.2.1 Normative References
The ISO /IEC 10646.2003 that is GB/T 13000-2010.
Consistency correspondence between this part of the normative international documents referenced with our file.
--- GB/T 30267.1-2013 Information technology section Biometric Application Programming Interface Chapter 1. BioAPI Specification
(ISO /IEC 19784-1.2006, IDT).
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This part of the National Information Technology Standardization Technical Committee (SAC/TC28) and focal points.
This section drafted by. China Electronics Standardization Institute, Zhejiang Bougainville Technology Co., Ltd., Beijing Vimicro.
The main drafters of this section. Yuan Li, Huo Hongwen, Lu Jie, Cuiguo Qin should Chun, Feng Jing, Jin Qian.
Introduction
This section defines conformance test methods biometrics, detailing three kinds compliance testing model can be applied separately, box
Racks and BSP, three BioAPI components for compliance testing. Also described for test assertions defined assertion language. BioAPI
The actual test assertions of each component in GB/T 30268 in the subsequent sections are defined.
This section also includes some of the concepts and guidelines for the establishment and management concepts BioAPI conformity assessment and verification procedures. Guidelines for
Identification of the claim compliance BioAPI the application of conformity assessment, and to verify the type of activity, response, service and documentation. In addition,
GB/T 30268 in this section provides a complete BioAPI establish conformity assessment methods guidelines.
--- Chapter 6. Introduction BioAPI test methods and conformance test model;
--- Chapter 7. Defining XML-based compliance testing assertion language;
--- Chapter 8. Defining elements assertion language;
--- Chapter 9. Introduction BioAPI conformance testing use BioAPI standard interface functions;
--- Chapter 10. built-in variables defined assertion language;
--- Chapter 11. Defining use XML syntax test log;
--- Chapter 12. Defining the use of XML syntax test report;
--- Chapter 13. Description BioAPI conformance test suite structure and basic concepts;
--- Appendix A. XML schema definition of the assertion language;
--- Appendix B. defines assertions ASN.1 language of architecture;
--- Appendix C. defines the XML Schema for the test log;
--- Annex D. Getting knowledge BioAPI describes the method of testing, including compliance testing process and test item description;
--- Annex E. describes the general framework for the entire BioAPI conformity assessment process;
--- Annex F. provides a diagram assertion language.
Reference lists some standards organizations, including. ISO , IEC , NIST, IEEE, and other published conformity assessment,
And compliance test file or organization White Paper 1).
1) GB/T 30268 This section contains excerpts references rather than references to these files.
Information technology - Biometric application program interface
(BioAPI) compliance testing
Part 1. Methods and procedures
1 Scope
1.1 GB/T 30268 into compliance with this Part BioAPI (see ISO /IEC 19784-1) compliance testing biometric products, Regulation
Set of concepts, frameworks, test methods and criteria. Also provided BioAPI conformance test suite guide, written to test assertions
Conformity and testing process to be followed.
1.2 part focuses comply BioAPI (see ISO /IEC 19784-1) compliance testing biometric products, do not pay attention biometric
Signature identification product testing or other types of testing other features (such as acceptability, performance, robustness, security, etc.). Not included for special
Given test biometric products.
1.3 section applies to conformance test methods -, BioAPI conformance test suite, in line with BioAPI product compliance testing process
Development and use of sequence; can be used for testing body, but can also be used for developers and users to test assertions and test methods.
2 Compliance
2.1 part BioAPI conformance test suite should support one or more compliance test model (see 6.2), and should be able to perform its support
Valid test assertion to test the model, these assertions are defined in Chapter 7 to Chapter 10.
Note. There are no restrictions on the form and structure of BioAPI conformance test suite, the contents of the communication between tasks or components such as the number of components, assemblies and completed
form.
2.2 BioAPI compliance test suite should be able to verify the correctness of any of the conformance test model included in the syntax, including the assertion
Or activities (or both both) (see 7.1.6), including the package does not support the compliance test model (if it exists).
2.3 For the compliance test model support, BioAPI conformance test suites and test should be able to carry out the activities necessary to interact (with
Body to a computing platform), you can call BioAPI standard interface function testing activities, testing activities and can receive BioAPI standard interfaces
Function calls itself.
Note 1. In compliance test model BioAPI application, does not require BioAPI conformance test suite can start or stop activities, but a mechanism is needed
To detect the beginning and end of the test activities.
Note 2. Not required BioAPI conformance test suite can test all consistent with basic standards activities. Including but not limited to. creating BioAPI Compliance
Circumstances platform test suite and create a platform for testing activities inconsistent; testing activities dependent on hardware (but the device can not be active in the test
Running on the running platform) situation.
2.4 BioAPI conformance test suite should generate a test log for each test campaign (see Chapter 11) and a test report (see para. 12
chapter).
If BioAPI 2.5 conformance test suite can not perform the basic activities of the test standard test, it should not be recorded in the test report
Execution rather not meet.
2.6 BioAPI conformance test suites should provide users with data input method, the data is necessary for the test.
Note. These data include assertions identifier (package name and the name of the assertion), asserts list of input parameters and all other information required in the test report (see para.
Chapter 12).
3 Normative References
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
|