Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 30032.2-2025 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Mobile elevating work platforms - Design, calculations, safety requirements and test methods relative to special features - Part 2: MEWPs with non-conductive (insulating) components
| Valid |
GB/T 30032.2-2025
|
GB/T 30032.2-2013 | English | 419 |
Add to Cart
|
3 days [Need to translate]
|
Mobile elevating work platforms -- Design, calculations, safety requirements and test methods relative to special features -- Part 2: MEWPs with non-conductive (insulating) components
| Valid |
GB/T 30032.2-2013
|
Basic data Standard ID | GB/T 30032.2-2025 (GB/T30032.2-2025) | Description (Translated English) | Mobile elevating work platforms - Design, calculations, safety requirements and test methods relative to special features - Part 2: MEWPs with non-conductive (insulating) components | Sector / Industry | National Standard (Recommended) | Date of Implementation | 2026-03-01 | Older Standard (superseded by this standard) | GB/T 30032.2-2013 |
GB/T 30032.2-2013: Mobile elevating work platforms -- Design, calculations, safety requirements and test methods relative to special features -- Part 2: MEWPs with non-conductive (insulating) components
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
. Mobile elevating work platforms Design, calculations, safety requirements and test methods relative to special features Part 2. MEWPs with non-conductive (insulating) components
ICS 53.020.99
J80
National Standards of People's Republic of China
Mobile elevating work platform with a special member
Design, calculations, safety requirements and test methods
Part 2. equipped with a non-conductive (insulating)
Mobile elevating work platform member
calculations, safetyrequirementsandtestmethodsrelativetospecialfeatures-
Part 2. MEWPswithnon-conductive (insulating) components
(ISO 16653-2.2009, MOD)
Issued on. 2014-03-01 2013-11-27 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
2 4 danger list
5 Safety requirements and/or protective measures 2
6 Safety requirements and/or protective measures of verification 4
7 Information 9
8 security principles, inspection, maintenance and operation 9
Appendix A (informative) manufacturing trademark licensing information template 14
Foreword
GB/T 30032 "design of mobile elevating work platforms with special parts, calculations, safety requirements and test methods" is divided into three
section.
--- Part 1. Mobile elevating work platforms equipped with retractable guardrail systems;
--- Part 2. equipped with a non-conductive mobile elevating work platforms (insulating) components;
--- Part 3. orchard operations for mobile elevating work platforms.
This section GB/T Part of 230,032.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses redrafted Law Amendment uses ISO 16653-2.2009 Design "mobile elevating work platforms with special elements,
Calculations, safety requirements and test methods - Part 2. Mobile elevating work platforms equipped with a non-conductive (insulating) components. "
This part of ISO 16653-2.2009 technical differences and the reasons are as follows.
--- GB 25849-2010 "Mobile elevating work platform design calculations, safety requirements and test methods" to modify using the international standard
Quasi ISO 16368.2003, this part of the normative references revised to GB 25849-2010.
--- According to the actual situation of China's power grid, the power distribution system voltage by the "46kV" to "35kV", and modify the phase in this section
It should RMS AC voltage; frequency is "60Hz" or "50Hz ~ 60Hz" to "50Hz", ie frequency.
--- Delete ISO 16653-2.2009 and in this part irrelevant footnote 1) and footnote 2).
For ease of use, this section made the following editorial changes.
--- ISO 16653-2.2009 is the "international standard" be replaced by "this section";
--- Delete ISO 16653-2.2009 preface and introduction, increase the foreword of this section.
This part is proposed by China Machinery Industry Federation.
This part of the National Standardization Technical Committee elevating work platform (SAC/TC335) centralized.
This section is drafted. Beijing Institute of Architectural mechanization, Terex (China) Investment Co., Ltd., Zhejiang full mechanical limited shares
The company, Hangzhou Aichi Engineering Vehicles Co., Ltd., Beijing Science and Technology Co., Ltd. CIB Machinery, XCMG Xuzhou Construction Machinery Research Institute.
The main drafters of this section. Yin Wenjing, Wang Xu roots, Chen Xiaofeng, Li Jing, Wu Rui.
Mobile elevating work platform with a special member
Design, calculations, safety requirements and test methods
Part 2. equipped with a non-conductive (insulating)
Mobile elevating work platform member
1 Scope
GB/T 30032 provisions of this section is equipped with a non-conductive (insulating) components of mobile elevating work platforms (hereinafter referred to as MEWP) of
Design, calculations, safety requirements and test methods. This section GB 25849 and supporting the use of.
This section applies equipped with a non-conductive (insulating) components of all types and sizes of MEWP, including the design and testing meet the manufacturer
Insulating member specific license consistent electrical performance. Such predetermined MEWP to the working position for transport of personnel, tools and equipment, in order to
Before working on the insulation above the boom segment of the working platform.
This section includes the structural design calculations, stability clauses applications, construction and MEWP equipped with non-conductive (insulating) components for the first time
Safety inspections and tests performed before. He pointed out that the use of various hazardous MEWP equipped with a non-conductive (insulating) components, also proposed elimination
Remove or reduce these risks approach.
This section refers to any member of the MEWP is not in contact with live parts of electrical equipment. MEWP non-conductive (insulating) components
Electrical performance should provide protection against accidental electrical non-conductive boom segment work platform on the end of the touch. If MEWP fitted bottom
Plate insulation system, which can provide protection against electrical ground personnel to prevent accidental touching of the top of the system.
This section does not apply to live working MEWP (see IEC 61057).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 25849-2010 Mobile elevating work platform design calculations, safety requirements and test methods (ISO 16368.2003,
MOD)
GB/T 27548-2011 Mobile elevating work platform safety rules, inspection, maintenance and operation (ISO 18893.2004, IDT)
Insulated high-altitude operation means (Liveworking-Insulatingaerial IEC 61057 Live Working mounted on the chassis
decivesformountingonachassis)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Chassis insulation system chassisinsulatingsystem
Installed in the system chassis and supporting the upper non-conductive (insulating) between the boom structure of a non-conductive (insulating) components.
NOTE. If the system is properly maintained, when that part of the accidental touching of live conductors between the upper MEWP non-conductive (insulating) boom with the system or with other
When electrical equipment, to provide insulation protection for the chassis.
|