US$929.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29233-2012: Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 29233-2012 | English | 929 |
Add to Cart
|
7 days [Need to translate]
|
Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application
| Valid |
GB/T 29233-2012
|
PDF similar to GB/T 29233-2012
Basic data | Standard ID | GB/T 29233-2012 (GB/T29233-2012) | | Description (Translated English) | Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | M33 | | Classification of International Standard | 33.180.10 | | Word Count Estimation | 42,453 | | Quoted Standard | GB/T 2951.11-2008; GB/T 6995.2; GB/T 7424.1-2003; GB/T 7424.2-2008; GB/T 7424.3-2003; GB/T 9771.1; GB/T 9771.2; GB/T 9771.3; GB/T 9771.4; GB/T 9771.5; GB/T 9771.6; GB/T 9771.7; GB/T 13993.2-2002; GB/T 13993.4-2002; GB/T 15972-10-2008; GB/T 15972-20-2008; | | Adopted Standard | IEC 60794-3-11-2010, MOD | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the pipeline, buried and non- self-supporting aerial installation with single-mode fiber optic cable communication outside the structure and materials, performance requirements, test methods, packaging, and transportation. This sta |
GB/T 29233-2012: Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Singlemode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application
ICS 33.180.10
M33
National Standards of People's Republic of China
Pipeline, buried and non-self-supporting aerial
Single-mode fiber optic cable laying Outdoor Communications
foroutdoorduct, directlyburied, andlashedaerialapplication
(IEC 60794-3-11.2010, Opticalfibrecables-Part 3-11. Outdoorcables
-Productspecificationforduct, Directlyburied, andlashedaerial
single-modeopticalfibretelecommunicationcables, MOD)
Issued on. 2012-12-31
2013-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 Symbols and abbreviations 2
5 General 3
6 6 Structures and Materials
7 performance requirements and test methods 10
8 packaging, transportation and storage 20
9 Quality Assurance 21
Appendix A (informative) This standard and IEC 60794-3-11.2010 structure change compared to the situation 22
Annex B (informative) This standard and IEC 60794-3-11.2010 technical differences and their causes 25
Appendix C (Informative Appendix) ITU-T and IEC Guide 28 standard single-mode fiber
Materials and features Appendix D (normative) single-mode fiber parameters 29
Annex E (informative) single-mode fiber compatibility guidelines 31
Design Guidelines Appendix F (informative) cable armouring is 34
Annex G (informative) cable avidin attack the protective layer of the design guidelines 36
References 38
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The revised standards adopted IEC 60794-3-11.2010 "Optical fiber cables - Part 3-11. Outdoor cables pipeline, buried and non-self-supporting frame
Empty communication singlemode fiber product specification. "
This standard and IEC 60794-3-11.2010, compared with more adjustment in the structure, listed in Appendix A of this standard and IEC 60794-
3-11. reg number 2010 control list.
This standard and IEC 60794-3-11.2010 compared to the existence of technical differences, these differences involve provisions have been adopted in its outer margin
Vertical single line blank position (|) were marked. Appendix B gives a list of corresponding technical differences and their causes.
This standard also made the following editorial changes.
--- For ease of use, the IEC 60794-3-11.2010 reference standard IEC /T R62000 increase this standard Annex E;
--- Increase the informative appendix F "cable armouring Design Guidelines";
--- Increase the informative Appendix G "cable avidin attack the protective layer of design guidelines."
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
The standard by the China Communications Standards Association.
This standard was drafted. Datang Telecom Technology & Industry Group, Beijing Institute of Telecommunications and beneficially through Science and Technology Co., Ltd., Wuhan Posts and Telecommunications
Academy of Sciences, Optical Fiber and Cable Co., Ltd.
The main drafters of this standard. Chi Meng Xue, Wang Zemin, Liu Xiangrong, Guo Zhihong, SONG Zhi Tacitus, Yangya Ning, bear strong, Gao Hua.
Pipeline, buried and non-self-supporting aerial
Single-mode fiber optic cable laying Outdoor Communications
1 Scope
This standard specifies the pipeline, buried and non-self-supporting aerial laying structure and material of a single-mode fiber optic cable outdoor communications, performance requirements, test
Methods, packaging and transportation.
This standard applies to pipes, buried or aerial self-supporting manner laid using single-mode fiber optic outdoor communication.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side
Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1.2001, IDT)
GB/T 6995.2 wire and cable identification methods - Part 2. Standard colors
GB/T 7424.1-2003 total cable specification - Part 1. General (IEC 60794-1-1.2001, MOD)
Basic optical cable test method. GB/T 7424.2-2008 cable Part 2 Generic specification (IEC 60794-1-2.2003, MOD)
GB/T 7424.3-2003 cable Part 3. Sectional specification - Outdoor cables (IEC 60794-3.2001, MOD)
GB/T 9771 (all parts) with a single-mode optical fiber communication
GB/T 13993.2-2002 communications cable series Part 2. Outdoor optical fiber core network
GB/T 13993.4-2002 communications cable series - Part 4. Outdoor optical fiber access networks
GB/T 15972-2008 (all parts) optical fiber test methods [IEC 60793-1 (all parts)]
Gases evolved during combustion of GB/T 17650.2-1998 materials from cables - Test methods - Part 2. Measurement
PH value and conductivity measurement of acidity of gases (idt IEC 60754-2.1991)
GB/T 17651.1-1998 Measurement of smoke density of cables burning under defined conditions - Part 1. Test apparatus (idt
IEC 61034-1.1997)
GB/T 17651.2-1998 of cables burning under defined conditions Measurement of smoke density - Part 2. Test procedure and requirements
(Idt IEC 61034-2.1997)
GB/T 18380.11-2008 and optical fiber cables under fire conditions - Test - Part 11. single insulated wire and cable fire
Vertical flame spread test test equipment (IEC 60332-1-1.2004, IDT)
GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire
Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2.2004, IDT)
GB/T 18900-2002 Test methods for polarization mode dispersion single mode fiber (ITU-TG.650.2000, NEQ)
GB/T 29199-2012 rodent cable performance test methods
JB/T 8137 (all parts) wire and cable delivery plate
YD/T 837.2-1996 Copper polyolefin insulated aluminum sheathed local communication cable test methods - Part 2. Electrical performance
experiment method
YD/T 837.3-1996 Copper polyolefin insulated aluminum sheathed local communication cable test methods - Part 3. mechanical and physical
Performance test method
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29233-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 29233-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 29233-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29233-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|