HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 29233-2012 English PDF

US$929.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 29233-2012: Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 29233-2012English929 Add to Cart 7 days [Need to translate] Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application Valid GB/T 29233-2012

PDF similar to GB/T 29233-2012


Standard similar to GB/T 29233-2012

YD/T 2554.1   GB/T 9771.1   GB/T 20186.1   GB/T 29230.1   GB/T 29231   GB/T 29229   

Basic data

Standard ID GB/T 29233-2012 (GB/T29233-2012)
Description (Translated English) Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard M33
Classification of International Standard 33.180.10
Word Count Estimation 42,453
Quoted Standard GB/T 2951.11-2008; GB/T 6995.2; GB/T 7424.1-2003; GB/T 7424.2-2008; GB/T 7424.3-2003; GB/T 9771.1; GB/T 9771.2; GB/T 9771.3; GB/T 9771.4; GB/T 9771.5; GB/T 9771.6; GB/T 9771.7; GB/T 13993.2-2002; GB/T 13993.4-2002; GB/T 15972-10-2008; GB/T 15972-20-2008;
Adopted Standard IEC 60794-3-11-2010, MOD
Regulation (derived from) National Standards Bulletin No. 41 of 2012
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the pipeline, buried and non- self-supporting aerial installation with single-mode fiber optic cable communication outside the structure and materials, performance requirements, test methods, packaging, and transportation. This sta

GB/T 29233-2012: Single mode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Singlemode optical fibre telecommunication cables for outdoor duct, directly buried, and lashed aerial application ICS 33.180.10 M33 National Standards of People's Republic of China Pipeline, buried and non-self-supporting aerial Single-mode fiber optic cable laying Outdoor Communications foroutdoorduct, directlyburied, andlashedaerialapplication (IEC 60794-3-11.2010, Opticalfibrecables-Part 3-11. Outdoorcables -Productspecificationforduct, Directlyburied, andlashedaerial single-modeopticalfibretelecommunicationcables, MOD) Issued on. 2012-12-31 2013-06-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 Symbols and abbreviations 2 5 General 3 6 6 Structures and Materials 7 performance requirements and test methods 10 8 packaging, transportation and storage 20 9 Quality Assurance 21 Appendix A (informative) This standard and IEC 60794-3-11.2010 structure change compared to the situation 22 Annex B (informative) This standard and IEC 60794-3-11.2010 technical differences and their causes 25 Appendix C (Informative Appendix) ITU-T and IEC Guide 28 standard single-mode fiber Materials and features Appendix D (normative) single-mode fiber parameters 29 Annex E (informative) single-mode fiber compatibility guidelines 31 Design Guidelines Appendix F (informative) cable armouring is 34 Annex G (informative) cable avidin attack the protective layer of the design guidelines 36 References 38

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The revised standards adopted IEC 60794-3-11.2010 "Optical fiber cables - Part 3-11. Outdoor cables pipeline, buried and non-self-supporting frame Empty communication singlemode fiber product specification. " This standard and IEC 60794-3-11.2010, compared with more adjustment in the structure, listed in Appendix A of this standard and IEC 60794- 3-11. reg number 2010 control list. This standard and IEC 60794-3-11.2010 compared to the existence of technical differences, these differences involve provisions have been adopted in its outer margin Vertical single line blank position (|) were marked. Appendix B gives a list of corresponding technical differences and their causes. This standard also made the following editorial changes. --- For ease of use, the IEC 60794-3-11.2010 reference standard IEC /T R62000 increase this standard Annex E; --- Increase the informative appendix F "cable armouring Design Guidelines"; --- Increase the informative Appendix G "cable avidin attack the protective layer of design guidelines." Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. The standard by the China Communications Standards Association. This standard was drafted. Datang Telecom Technology & Industry Group, Beijing Institute of Telecommunications and beneficially through Science and Technology Co., Ltd., Wuhan Posts and Telecommunications Academy of Sciences, Optical Fiber and Cable Co., Ltd. The main drafters of this standard. Chi Meng Xue, Wang Zemin, Liu Xiangrong, Guo Zhihong, SONG Zhi Tacitus, Yangya Ning, bear strong, Gao Hua. Pipeline, buried and non-self-supporting aerial Single-mode fiber optic cable laying Outdoor Communications

1 Scope

This standard specifies the pipeline, buried and non-self-supporting aerial laying structure and material of a single-mode fiber optic cable outdoor communications, performance requirements, test Methods, packaging and transportation. This standard applies to pipes, buried or aerial self-supporting manner laid using single-mode fiber optic outdoor communication.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 6995.2 wire and cable identification methods - Part 2. Standard colors GB/T 7424.1-2003 total cable specification - Part 1. General (IEC 60794-1-1.2001, MOD) Basic optical cable test method. GB/T 7424.2-2008 cable Part 2 Generic specification (IEC 60794-1-2.2003, MOD) GB/T 7424.3-2003 cable Part 3. Sectional specification - Outdoor cables (IEC 60794-3.2001, MOD) GB/T 9771 (all parts) with a single-mode optical fiber communication GB/T 13993.2-2002 communications cable series Part 2. Outdoor optical fiber core network GB/T 13993.4-2002 communications cable series - Part 4. Outdoor optical fiber access networks GB/T 15972-2008 (all parts) optical fiber test methods [IEC 60793-1 (all parts)] Gases evolved during combustion of GB/T 17650.2-1998 materials from cables - Test methods - Part 2. Measurement PH value and conductivity measurement of acidity of gases (idt IEC 60754-2.1991) GB/T 17651.1-1998 Measurement of smoke density of cables burning under defined conditions - Part 1. Test apparatus (idt IEC 61034-1.1997) GB/T 17651.2-1998 of cables burning under defined conditions Measurement of smoke density - Part 2. Test procedure and requirements (Idt IEC 61034-2.1997) GB/T 18380.11-2008 and optical fiber cables under fire conditions - Test - Part 11. single insulated wire and cable fire Vertical flame spread test test equipment (IEC 60332-1-1.2004, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2.2004, IDT) GB/T 18900-2002 Test methods for polarization mode dispersion single mode fiber (ITU-TG.650.2000, NEQ) GB/T 29199-2012 rodent cable performance test methods JB/T 8137 (all parts) wire and cable delivery plate YD/T 837.2-1996 Copper polyolefin insulated aluminum sheathed local communication cable test methods - Part 2. Electrical performance experiment method YD/T 837.3-1996 Copper polyolefin insulated aluminum sheathed local communication cable test methods - Part 3. mechanical and physical Performance test method

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 29233-2012_English be delivered?

Answer: Upon your order, we will start to translate GB/T 29233-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 29233-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 29233-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.