US$599.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29199-2012: Test methods for rodent resistance of optical fiber cable Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 29199-2012 | English | 599 |
Add to Cart
|
5 days [Need to translate]
|
Test methods for rodent resistance of optical fiber cable
| Valid |
GB/T 29199-2012
|
PDF similar to GB/T 29199-2012
Basic data | Standard ID | GB/T 29199-2012 (GB/T29199-2012) | | Description (Translated English) | Test methods for rodent resistance of optical fiber cable | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | M33 | | Classification of International Standard | 33.180.10 | | Word Count Estimation | 26,269 | | Quoted Standard | GB/T 1040.2-2006; GB 14922.1-2001; GB 14922.2-2001; GB 14924.2-2001; GB 14924.3-2010; GB 14925-2010; GB/T 16491-2008; GB/T 19291-2003 | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies three rodent performance test methods, including test specimen, devices, procedures, and test results indicate reports. This standard applies to single-layer or multi-layer metal armor with a device does not contain any chemicals r |
GB/T 29199-2012: Test methods for rodent resistance of optical fiber cable---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods for rodent resistance of optical fiber cable
ICS 33.180.10
M33
National Standards of People's Republic of China
Rodent cable performance test methods
Issued on. 2012-12-31
2013-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 General 3
5 A method of etching cycle rat-bite 3
5.1 Overview 3
5.2 Sample 3
5.3 Test apparatus and conditions 3
Program 6 5.4
5.5 Expression of results 7
5.6 Test Report 7
6 Mechanical Simulation Method B Method 8 rat bite
6.1 Overview 8
6.2 Sample 8
6.3 Test apparatus 9
6.4 Calibration Procedure 10
6.5 Procedures 11
6.6 Expression of results 11
6.7 Test Report 11
7 C direct methods rat-bite law 12
7.1 Overview 12
7.2 Sample 12
7.3 Test apparatus and conditions 12
7.4 Program 13
7.5 Expression of results 13
7.6 rat bite resistant capability index meaning 14
7.7 Test Report 14
Test flow chart in Appendix A (normative) Method A 16
Appendix B (normative) metal armor layer corrosion perforation conversion coefficient to calculate the number of days 17
Appendix C (Informative Appendix) Wistar rats sample 19 test results
References 21
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
The standard by the China Communications Standards Association.
This standard was drafted. Beijing CCS Optical Fiber Cable Co., Ltd., Chengdu CCS Optical Fiber Cable Co., Ltd., Beijing University of Posts and Telecommunications, Beijing Tong and beneficial electricity
Letter Institute of Science and Technology Co., Ltd., Wuhan Research Institute of Posts and Telecommunications, Optical Fiber and Cable Co., Ltd., Jiang Su Yongding Co., Ltd., Jiangsu
Su Heng photoelectric Limited.
The main drafters of this standard. Ji Lei, Yang Shixin, Xiao Bin, Wang Zhenyue, SONG Zhi Tacitus, Lei Fei, Shi Huiping Xiong Zhuang, Chen Xiaohong, Ma Jianlin.
Introduction
Cable industry calls "Rodents", usually due to the laying of the cable environment caused by a rodent bite function failure, reduced service life
Short and communication is interrupted. Rodents communication failure caused by social and economic activities suffered immeasurable loss. "Rodent" concept in
"Rat" refers to cause such damage to the cable rodent.
Three test methods specified in this standard are focused on testing several different rodent face cable capacity. Setting the standard mouse, rat by the standard of
Different mouse; bite cable and fiber optic cable by rodents after a comprehensive evaluation of corrosion resistance, to unify the evaluation of the performance of different rodent cable
Disaster Type, simulation mouse teeth to improve the consistency of test results, and speed testing and design of the cable puncture resistance test; different
Type of rodent, rodents cable through the bite of non-metallic material damage characteristics evaluation of the cable sheath to prevent the ability to target specific mouse. needle
Different aspects and different purposes rodent cable capacity, different selection methods specified in this standard may be tested.
Chemical rodent and non-metallic cable test methods to be rodent-repellent effect study.
Users of this standard is recommended for rodents performance indicators and the practical application of the cable collection, comparison, clearly laying different environment
Cable performance requirements rodents, rodent cable guide and promote the design, manufacture and application.
When issuing authority of the document drew attention to the statement of compliance with this document may involve Chapter 6, "Method B Mechanical Simulation rat bite Law"
And Cable and material destruction of anti-rodent test methods and apparatus related to the ability to use the patent.
The issuing authority for the patent document authenticity, validity and scope without any position.
The patent holder has to ensure that the issuing authority of the document, he was willing to reasonable and non-discriminatory terms and conditions with any applicant,
Patent licensing negotiations. The patent holder's statement has been filed in the release mechanism of the present document. Related information is available through the following
Contact at.
Patent holder. Chengdu CCS Optical Fiber Cable Co., Ltd.
Address. Siemens Road, Chengdu, Sichuan, China Hi-tech Development Zone No. 1
Please note that in addition to the above patents, some of the contents of this document may still involve patents. The issuing authority of this document does not undertake to recognize these special
Lee responsibility.
Rodent cable performance test methods
1 Scope
This standard specifies three rodent performance test methods and test reports showing samples include testing apparatus, procedures, results and so on.
This standard is applicable to a single-layer or multi-layer metal armor and does not contain any chemicals like repellent cable sheath materials, metal armor
Rodent-repellent properties of materials evaluation. Wherein the metal armor layer may be a metal pipe, longitudinally (or wrapping) metal strip or stranded (or woven) wire.
Rodent performance testing of similar structure to other products such as cables can also refer to use.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB /1040.2-2006 Plastics Determination of tensile properties T Part 2. Test plastics molding and extrusion conditions
GB 14922.1-2001 Laboratory Animal parasitology rating and monitoring
GB 14922.2-2001 Laboratory Animal Microbiology rating and monitoring
GB 14924.2-2001 animal feed hygiene standards
GB 14924.3-2010 animal feed nutrients
GB 14925-2010 Laboratory Animal Facilities and Environment
GB/T 16491-2008 electronic universal testing machine
GB/T 19291-2003 Corrosion test Corrosion of metals and alloys General principles (ISO 11845.1995, IDT)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Control sheath material referencesheathmaterial
Customer consultation and evaluation unit selected for rat bite test, as compared to the reference cable jacket material.
3.2
Control samples cable referencecablesample
Sheath material with a certain thickness of the control cable as a sample jacket layer.
3.3
Indented single type debris onetoothmarkgnawedpiece
Rat bite sample produced only one incisor bite marks debris, shown in Figure 1.
Figure 1 Single-type debris scalloped
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29199-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 29199-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 29199-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29199-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|