HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 2900.59-2008 English PDF

US$489.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 2900.59-2008: Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Substations
Status: Valid

GB/T 2900.59: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 2900.59-2008English489 Add to Cart 4 days [Need to translate] Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Substations Valid GB/T 2900.59-2008
GB/T 2900.59-2002English759 Add to Cart 3 days [Need to translate] Electrician term power generation, transmission and distribution substation Obsolete GB/T 2900.59-2002

PDF similar to GB/T 2900.59-2008


Standard similar to GB/T 2900.59-2008

GB/T 2424.7   GB/T 2424.5   GB/T 2900.50   GB/T 2900.65   GB/T 2900.55   GB/T 2900.64   

Basic data

Standard ID GB/T 2900.59-2008 (GB/T2900.59-2008)
Description (Translated English) Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Substations
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K04
Classification of International Standard 01.040.29
Word Count Estimation 21,267
Date of Issue 2008-06-18
Date of Implementation 2009-05-01
Older Standard (superseded by this standard) GB/T 2900.59-2002
Adopted Standard IEC 60050-605-1983, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 10 of 2008 (total 123)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the generation, transmission and distribution substation terminology related fields. This standard applies to power system planning, management, design, power generation, transmission and distribution and other fields.

GB/T 2900.59-2008: Electrotechnical terminology -- Generation, transmission and distribution of electricity -- Substations


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electrotechnical terminology. Generation, transmission and distribution of electricity. Substations ICS 01.040.29 K04 National Standards of People's Republic of China Replacing GB/T 2900.59-2002 Electrotechnical terminology Generation, transmission and distribution substations (IEC 60050-605. 1983, MOD) Posted 2008-06-18 2009-05-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Terms and definitions 1 2.1 Substation Type - Substations arrangement 1 2.2 transformer substation apparatus 5 Substation secondary equipment 2.3 9 Chinese index 11 English 13 Index

Foreword

This section GB/T 2900 Part 59. The partial modification of the use of IEC 60050-605. 1983 "International Electrotechnical Vocabulary - Part 605. Generation, transmission and distribution substations" And with reference to the International Electrotechnical Commission 2003 document (1/1906/CD), modify the definition of some terms used. This part of IEC 60050-605. Compared to 1983, there is a technical difference. --- 602-02-11 [12], 605-03-01 [2] were changed to separate two; --- Modified 605-01-01,605-02-37 such definitions; --- Remove IEC 60050-605. 605-02-37 1983 in the second English term "substationrelaykiosk". This Part replaces GB/T 2900.59-2002 "Electrotechnical terminology Generation, transmission and distribution substations." This section compared with the GB/T 2900.59-2002 main changes are as follows. --- 605-01-19 and 605-01-20 of the Chinese term increase "bus" instructions; --- 604-02-32 Chinese term "silencer shell" to "muffler shell"; --- 605-01-25 Chinese term increase "sesqui-breaker"; --- Modified, "605-02-37 substation relay chamber" is defined as "605-01-01 substation." This part of the National Electrotechnical Terminology Standardization Technical Committee (SAC/TC232) and focal points. This in part by China Electric Power Research Institute, Mechanical Science Research Institute and the China Electricity Council is responsible for drafting scientific enterprise. The main drafters of this section. Xinde Pei Wei rounder, Yang Fu, to the king. This part of the standard replaces the previous editions are. --- GB/T 2900.59-2002. Electrotechnical terminology Generation, transmission and distribution substations

1 Scope

This standard specifies the generation, transmission and distribution in the field of terminology related substations. This standard applies to the planning, management, design, power generation, transmission and distribution and other areas of power system.

2 Terms and definitions

2.1 Substation Type - Substations arrangement Note. "substation" also known as "substation." 605-01-01 Part of the power system, which is concentrated in a designated place, including the terminal transmission or distribution line and switch and control equipment Buildings and transformers. Typically include power system security and control of the necessary facilities (such as protective devices). Note. Depending on the nature of the system contains a substation can add a prefix to define the word in front of the substation. For example .( a transmission system) Transmission and Distribution Stations, power distribution substation, 500kV substation, 35kV substation. 605-01-02 With a switch device, also typically includes bus, but no power transformer substation. 605-01-03 Transformer two or more different voltage levels of the network connecting the substation. 605-01-04 Transformer output voltage higher than the input voltage of the transformer substation. 605-01-05 Transformer output voltage is lower than the input voltage of the transformer substation. 605-01-06 The main substation to the traction power supply system. 605-01-07 Mounted inverter and are mainly used to convert alternating current or direct current into AC substation. 605-01-08 Frequency alternating current can be converted from one substation to another frequency. 605-01-09 There substation operating personnel on duty.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 2900.59-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 2900.59-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 2900.59-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 2900.59-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 2900.59-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 2900.59-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.