US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 28112-2011: Determination of residual dimethylcyclosiloxane volatiles in silicone rubber Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 28112-2011 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Determination of residual dimethylcyclosiloxane volatiles in silicone rubber
| Valid |
GB/T 28112-2011
|
PDF similar to GB/T 28112-2011
Basic data | Standard ID | GB/T 28112-2011 (GB/T28112-2011) | | Description (Translated English) | Determination of residual dimethylcyclosiloxane volatiles in silicone rubber | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G34 | | Classification of International Standard | 83.060 | | Word Count Estimation | 10,184 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-10-01 | | Quoted Standard | GB/T 8170-2008; GB/T 14838-2009; GB/T 15340-2008 | | Adopted Standard | ASTM F2466-2005, NEQ | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 23 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the gas chromatographic determination of residual silicone rubber raw rubber ring of volatile methyl siloxanes D4 (Octamethyl siloxane) ~ D10 (twenty ten ring methyl siloxane) content of the principle and test methods. This standard applies to silicone rubber raw rubber, hexamethyldisiloxane (D4 ~ D10) single-component detection limit was 50mg/kg. |
GB/T 28112-2011: Determination of residual dimethylcyclosiloxane volatiles in silicone rubber---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of residual dimethylcyclosiloxane volatiles in silicone rubber
ICS 83.060
G34
National Standards of People's Republic of China
Silicone rubber volatile methyl siloxane ring
Determination of residues
Issued on. 2011-12-30
2012-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard with the American Society for Testing Materials Standards ASTMF2466-05 "Transport silicone rubber silicone volatiles standard measurement
Practice, "the non-equivalent.
The presence of the following standards and technical differences compared ASTMF2466-05.
--- Different ranges apply. This standard applies to silicone raw rubber, while ASTMF2466-05 applicable to vulcanized silicone rubber products.
--- Different extraction agent. This standard uses acetone as an extracting agent, and ASTMF2466-05 using n-pentane as the extraction agent.
--- Different detector works. The standard gas chromatography flame ionization detector (FID) detection method, ASTM
F2466-05 by GC thermal conductivity detector (TCD) detection method.
--- The standard selection decamethylcyclopentasiloxane siloxane (D5) or twelve six methyl siloxane ring (D6) as one of the standard, n-tetradecane
Hydrocarbons (n-C14H30) or n-dodecane (n-C12H26) as an internal standard one, was tested with the standard relative to the internal standard
Correction factor, the determination of silicon rubber adhesive residual volatile methyl siloxane ring (D4 ~ D10) content in the standard method. ASTM
F2466-05 need seven hexamethyldisiloxane (D4 ~ D10) and n-dodecane total of eight standard samples in Volatile
Of hexamethyldisiloxane (D4 ~ D10) was quantified.
--- Qualitatively different form of standard control samples. This standard uses a mixed methyl siloxane ring (D4 ~ D10) standard still
Products, and ASTMF2466-05 Methods D4 ~ D10 seven separate hexamethyldisiloxane standard sample.
--- Increased gas chromatography - mass spectrometry (GC-MS) qualitative methods.
--- Increasing the precision of the method.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Rubber and rubber products Standardization Technical Committee (SAC/TC35) centralized.
This standard was drafted. Zhongshan University Testing Center, China Research Institute of Petroleum Chemical Industry Co., Ltd..
Drafters of this standard. Xie Xi Mei, Lu Huining, Sun Lijun, Qin Peng.
Silicone rubber volatile methyl siloxane ring
Determination of residues
WARNING 1 --- personnel should use this standard regular laboratory work experience. This standard does not point out all possible security
problem. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
Warning 2 --- some of the steps of the standard substances and waste generated in the local environment may be damaged. An after use should be developed
Documents the whole process.
1 Scope
This standard specifies the determination by gas chromatography silicone raw rubber residual volatile hexamethyldisiloxane D4 (octamethylcyclotetrasiloxane siloxane) ~
D10 (twenty-methyl siloxane ring ten) principles and test methods for the content.
This standard applies to silicone gum, methyl siloxane ring (D4 ~ D10) single-component minimum detectable amount of 50mg/kg.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 8170-2008 revised value represents about rules and limit values \u200b\u200band judgment
GB/T 14838-2009 Rubber and rubber products - Determination of precision for test method standards (ISO /T R9272.2005, IDT)
GB/T 15340-2008 natural and synthetic rubber raw sampling and sample preparation method (ISO 1795.2000, IDT)
Principle 3
Anhydrous sodium sulfate dispersed silicone rubber adhesive samples, and then soaked in acetone, volatile methyl silicone ring wherein ultrasonic extraction residues
Alkyl, gas chromatography flame ionization detector (FID) detection. Qualitative mixed methyl siloxane ring (D4 ~ D10) of reference standards
Retention time qualitative or GC-MS characterization. According hexamethyldisiloxane same hydrocarbon composition ratio of each component of the same quality as methyl cyclosila
Siloxane consistent response on the FID detector to decamethylcyclopentasiloxane siloxane (D5) or twelve six methyl siloxane ring (D6) as a standard,
Fourteen n-paraffins (n-C14H30) or n-dodecane (n-C12H26) as internal standard to determine the relative calibration factor. Determination by internal standard method each
The residual amount of methyl cyclosiloxanes.
4 Instrument
Conventional laboratory equipment and the following.
4.1 Gas Chromatograph (GC). with autosampler or manual injection device, equipped with a flame ionization detector (FID), to meet the analysis
Requirements; qualitative analysis can also be used by gas chromatography - mass spectrometry (GC-MS).
4.2 Capillary column. 100% non-polar highly inert dimethylpolysiloxane crosslinked capillary column DB-1 (30m × 0.25mm ×
0.25μm), it can also be used to achieve other equivalent separation of non-polar capillary column.
4.3 Data processing system. chromatographic integrator or chromatography workstation.
4.4 Analytical balance. accurate to 0.1mg.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 28112-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 28112-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 28112-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 28112-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|