US$374.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27894.6-2012: Natural gas -- Determination of composition with defined uncertainty by gas chromatography -- Part 6: Determination of hydrogen helium oxygen nitrogen carbon dioxide and C1 to C8 hydrocarbons using three capillary columns Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 27894.6-2012 | English | 374 |
Add to Cart
|
3 days [Need to translate]
|
Natural gas -- Determination of composition with defined uncertainty by gas chromatography -- Part 6: Determination of hydrogen helium oxygen nitrogen carbon dioxide and C1 to C8 hydrocarbons using three capillary columns
| Valid |
GB/T 27894.6-2012
|
PDF similar to GB/T 27894.6-2012
Basic data | Standard ID | GB/T 27894.6-2012 (GB/T27894.6-2012) | | Description (Translated English) | Natural gas -- Determination of composition with defined uncertainty by gas chromatography -- Part 6: Determination of hydrogen helium oxygen nitrogen carbon dioxide and C1 to C8 hydrocarbons using three capillary columns | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | E24 | | Classification of International Standard | 75.060 | | Word Count Estimation | 19,119 | | Quoted Standard | GB/T 27894.1-2012; ISO 6142; ISO 6143; ISO 6974-2; ISO 7504 | | Adopted Standard | ISO 6974-6-2002, IDT | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the three capillary columns of the quantitative determination of nitrogen gas, helium, oxygen, nitrogen, carbon dioxide and C1 to C8 hydrocarbon content of a gas chromatography. This method is applicable to the analysis given in Ta |
GB/T 27894.6-2012: Natural gas -- Determination of composition with defined uncertainty by gas chromatography -- Part 6: Determination of hydrogen helium oxygen nitrogen carbon dioxide and C1 to C8 hydrocarbons using three capillary columns
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS75.060
E24
National Standards of People's Republic of China
GB/T 27894.6-2012/ISO 6974-6.2002
Natural gas under certain uncertainty by gas
Chromatography composition Part 6. The three
Capillary column Determination of hydrogen, helium, oxygen, nitrogen,
Carbon dioxide and hydrocarbons C1 to C8,
chromatography-Part 6. Determinationofhydrogenheliumoxygennitrogen
(ISO 6974-6.2002, IDT)
Issued on. 2012-12-31 2013-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 2
3 Principle 3
3.1 Analysis of gas samples 3
3.2 Analysis of SNG 3
4 material 3
4.1 3 carrier gas
4.2 auxiliary gas 3
4.3 Reference gas 4
5 Apparatus 4
5.1 Gas Chromatograph System 4
5.2 Capillary Column 7
6 Step 8
6.1 Operating conditions 8
6.2 Performance Requirements 9
6.3 Determination of 10
7 Calculation 13
8 Precision 13
9 13 test reports
Appendix A (informative) typical precision value 14
References 15
GB/T 27894.6-2012/ISO 6974-6.2002
Foreword
GB/T 27894 "natural gas under certain uncertainty by gas-phase chromatography composition" is divided into six parts.
--- Part 1. Analysis of guidelines;
--- Part 2. measurement system characteristics and statistics;
--- Part 3. with two packed columns Determination of hydrogen, helium, oxygen, nitrogen, carbon dioxide and hydrocarbons up to C8;
--- Part 4. laboratory and on-line measuring system using two columns Determination of nitrogen, carbon dioxide and C1 to C5 and C6 of
Hydrocarbons;
--- Part 5. using laboratory and on-line processing system three columns Determination of nitrogen, carbon dioxide and C1 to C5 and C6 of
Hydrocarbons;
--- Part 6. Determination of capillary column with three of hydrogen, helium, oxygen, nitrogen, carbon dioxide and hydrocarbons C1 to C8's.
This is Part 6 GB/T 27894 in.
Rules in this section in accordance with GB/T 1.1-2009 given draft.
This section uses the translation method identical with ISO 6974-6.2002 "gas at a certain degree of uncertainty with the composition determined by gas chromatography method
Part 6. Determination of capillary column with three of hydrogen, helium, oxygen, nitrogen, carbon dioxide and C1 to C8 hydrocarbons. "
Consistent correspondence between this standard international documents and normative references of the following documents.
--- GB/T 5274-2008 gas analyzer calibration weighing method for preparing a mixed gas (ISO 6142.2001, IDT)
--- GB/T 10628-2008 Gas analysis - Determination of the composition of calibration gas mixtures and calibration Comparative Law (ISO 6143.2001,
IDT)
--- GB/T 14850-2008 gas analysis vocabulary (ISO 7504.2001, IDT)
--- GB/T 27894.2-2012 natural gas under certain uncertainty by gas chromatography to determine the composition Part 2. Measurement
System characteristics and statistics (ISO 6974-2.2001, IDT)
This part of the National Gas Standardization Technical Committee (SAC/TC244) centralized.
This section drafted by. China Petroleum Daqing Oilfield Engineering Co., Ltd., China Petroleum and Natural Gas Research Institute, Southwest Oil and Gas Field Company.
The main drafters of this section. Tan for the group, Li Nan, Pu Jianshu, Tang Meng, late Yongjie.
GB/T 27894.6-2012/ISO 6974-6.2002
Natural gas under certain uncertainty by gas
Chromatography composition Part 6. The three
Capillary column Determination of hydrogen, helium, oxygen, nitrogen,
Carbon dioxide and hydrocarbons C1 to C8,
1 Scope
This section GB/T 27894 gives the determination of hydrogen gas with three quantitative capillary column, helium, oxygen, nitrogen, carbon dioxide and
C1 to C8 hydrocarbon content of a gas chromatography. This method is suitable for analysis within the range of mole fractions given in Table 1 gas group
Min. These ranges do not represent the detection limit, and that the use of the method in this range to achieve a predetermined precision. While the sample will have a
Or more of the components can not be detected, but this method can still apply.
In conjunction with Part 2 GB/T 27894 This part of the GB/T 27894 Part 1 and GB/T 27894 in.
The method is also suitable for the analysis of substitute natural gas.
Table 1 Scope
Component formula mole fraction /%
Helium He 0.002 ~ 0.5
Hydrogen H2 0.001 ~ 0.5
Oxygen O2 0.007 ~ 5
Nitrogen N2 0.007 ~ 40
Methane CH4 40 ~ 100
Carbon monoxide a CO 0.001 ~ 1
Carbon dioxide CO2 0.001 ~ 10
Acetylene a C2H2 0.001 ~ 0.5
Ethylene a C2H4 0.001 ~ 0.5
Ethane C2H6 0.002 ~ 15
Propylene a, b C3H6 0.001 ~ 0.5
Propane b C3H8 0.001 ~ 5
Isobutane C4H10 0.0001 ~ 1
Butane C4H10 0.0001 ~ 1
2,2-dimethyl propane (neopentane) C5H12 0.0001 ~ 0.5
2-methylbutane (isopentane) C5H12 0.0001 ~ 0.5
Pentane C5H12 0.0001 ~ 0.5
GB/T 27894.6-2012/ISO 6974-6.2002
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 27894.6-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 27894.6-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 27894.6-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27894.6-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|