|
US$529.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 27747-2011: High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72.5 kV and above Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 27747-2011 | English | 529 |
Add to Cart
|
4 days [Need to translate]
|
High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72.5 kV and above
| Valid |
GB/T 27747-2011
|
PDF similar to GB/T 27747-2011
Basic data | Standard ID | GB/T 27747-2011 (GB/T27747-2011) | | Description (Translated English) | High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72.5 kV and above | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K43 | | Classification of International Standard | 29.130.10 | | Word Count Estimation | 23,252 | | Date of Issue | 2011-12-30 | | Date of Implementation | 2012-05-01 | | Quoted Standard | GB 1984; GB 1985; GB/T 2900.19-1994; GB/T 2900.20-1994; GB/T 2900.57-2008; GB/T 11022; IEC/TS 60815-1-2008; IEC/TR 62271-310-2008 | | Adopted Standard | IEC 62271-108-2005, MOD | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 22 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard applies to design and installation indoors or outdoors and run the system at a frequency of 50Hz rated voltage 72. 5 kV and above AC isolation breaker. This standard was confirmed GB/T 11022, GB 1984 and GB 1985 requested the applicable sections of these devices are also given specific additional requirements. This standard covers the Court in the position of circuit breakers and disconnectors satisfy both requirements. This standard describes in detail the isolation Adams Road is independent functional interaction between the requirements, a clear separation of these requirements with an independent circuit breakers and disconnectors differences between the requirements. |
GB/T 27747-2011: High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72.5 kV and above ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
High-voltage alternating current disconnecting circuit-breakers for rated voltages of 72.5 kV and above
ICS 29.130.10
K43
National Standards of People's Republic of China
Rated voltage of 72.5kV and above AC isolation breaker
(IEC 62271-108.2005, MOD)
Issued on. 2011-12-30
2012-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Overview 1
2 Normal and special conditions of use
3 Terms and definitions
Rating 3 4
5 Design and Structure 8
6 Type Test 10
7 factory test 16
8 isolated Breaker Selection Guide 17
9 Inquire with information, the tender offer and order 17
10 transport, storage, installation, operation and maintenance of the rule 17
11 Safety 17
The impact on the environment 12 17
Appendix A (informative) isolation breaker explanatory notes and examples 18
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard and GB/T 11022, GB 1984, GB 1985 together. To simplify the representation of the same requirements, this standard reg number
11022 consistent with GB/T . Supplementary content of these clauses are given in the same reference under the heading, and additional terms numbered starting from 101.
This standard uses redrafted law revision using IEC 62271-108.2005 "Part 108 high-voltage switchgear and control equipment. the amount
72.5kV and above constant voltage AC high voltage isolation breaker. "
This standard and IEC 62271-108.2005 main difference is reflected in.
--- Rated frequency.
According to the actual situation of China's power grid, removing the IEC 62271-108.2005 rated frequency of 60Hz;
--- Rated voltage.
According to China's power grid, the voltage range is divided into.
72.5kV, 126kV, 252kV, 363kV, 550kV, 800kV;
--- Terminals static load rating.
According to the level of the voltage level of the IEC 62271-108.2005 in Table 1 and the terminal rated current range of static load value
Modify considered in a multi-column isolation breaker situation, circuit breakers and disconnectors side terminal side terminal static load value;
--- Increased Chapter 12. Effect of the relevant requirements of the product on the environment;
--- Appendix A Figure A.3 increase the circuit breaker and isolating switch interlock mechanism Fig.
The chapters in this standard, the order of the arrangement with the IEC 62271-108.2005 agreement, the contents of most of the provisions of IEC 62271-108.
2005 same, except that the main difference has been given instructions.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national high-voltage switch equipment Standardization Technical Committee (SAC/TC65) centralized.
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., Sunrise Holdings Limited, China Electric Power Research Institute High
Voltage switchgear Institute, Henan high level of electrical Co., Ltd., Xi'an high-voltage electrical Co., Ltd., Xi'an High Voltage Switch Co.
Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co. Institute, high-voltage electrical machinery industry product quality inspection center (Shenyang),
Ltd. Hangzhou Gaudet high voltage electrical equipment, ABB (China) Co., Ltd. High Pressure Technology Center, Ningbo Tianan (Group) Co., Ltd.,
Chint Electric Co., Ltd., Zhejiang Switch Factory Co., Ltd., Shaanxi Electric Power Research Institute, Shandong Taikai high voltage switch Ltd., Hebei
Provincial Electric Power Research Institute, Shanghai Electric Power Transmission and Distribution Limited testing center.
Drafters of this standard. Tian Enwen, travel Yimin, Pingwu Jun, Xu Jingjiang, Pan Yongcheng, Dongchuan Qi, Li Qingyu, Guan Xing Yan, Wu Junhui, Mo Kang,
Wang Tianxiang, Zhang Shu, Yang Kun, Deng Meng, Zhang interlocking, which Wang Kai, Gong Chen, Liu all, Su Weimin, Lu Zhen Mei, Yang Ren and Li Zhonghua, Panjin, Luo Shicong,
Xingjian.
Rated voltage of 72.5kV and above AC isolation breaker
1 Overview
1.1 Scope
This standard applies to the design and installation indoors or outdoors and run at a frequency of 50Hz system rated voltage 72.5kV and above
AC isolation circuit breaker.
Note 1. The rated voltage 72.5kV AC isolation breaker may refer to this standard.
This standard was confirmed GB/T 11022, GB 1984 GB 1985 and applicable sections of the requirements, but also gives a unique kind of attachment means
Canadian requirements.
This standard covers the OFF position while meeting the requirements of the circuit breakers and disconnectors devices.
This standard describes in detail the requirements for isolation breaker function independent interaction and clear these requirements with the circuit breaker and the separate compartment
Leaving the independent claim related to the difference between.
Note 2. The isolation breaker explanatory notes and illustrated in Appendix A.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated edition applies to this
file. For undated references, the latest edition (including any amendments) applies to this document.
GB 1984 high voltage AC circuit breaker (IEC 62271-100.2001, MOD)
GB 1985 high-voltage AC disconnectors and earthing switches (IEC 62271-102.2002, MOD)
GB/T 2900.19-1994 Electrotechnical term high voltage test technique and insulation coordination (neqIEC 60071-1.1993)
GB/T 2900.20-1994 Electrotechnical terminology voltage switchgear (neqIEC 60050-441. 1984)
GB/T 2900.57-2008 Electrotechnical terminology Generation, transmission and distribution operations (IEC 60050-604. 1987, MOD)
GB/T 11022 high-voltage switchgear and control equipment standard common technical requirements (IEC 62271-1.2007, MOD)
IEC /T S60815-1. under the 2008 definition of pollution conditions, information and general principles with high-voltage insulators and choose the size Selec-
tionanddimensioningofhigh-voltageinsulatorsintendedforuseinpolutedconditions-Definitions,
informationandgeneralprinciples
IEC /T R62271-310.2008 high-voltage switchgear and controllers - Part 310. Electrical circuit breakers rated voltage 52kV
Durability Test High-voltageswitchgearandcontrolgear-Part 310. Electricalendurancetestingfor
circuit-breakersaratedvoltage52kV
2 Normal and special service conditions
GB/T 11022 Chapter 2 apply.
3 Terms and Definitions
The following terms and definitions apply to this document.
Note 1. For ease of reference, GB/T 2900.19, GB/T 2900.20, part of the definition GB/T 2900.57 and GB/T 11022 in this re-listed.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 27747-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 27747-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 27747-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27747-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|