Fluid flow in closed conduits -- Connections for pressure signal transmissions between primary and secondary elements
| Valid |
GB/T 26801-2011
|
PDF similar to GB/T 26801-2011
Basic data | Standard ID | GB/T 26801-2011 (GB/T26801-2011) | | Description (Translated English) | Fluid flow in closed conduits -- Connections for pressure signal transmissions between primary and secondary elements | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | N12 | | Classification of International Standard | 17.120.10 | | Word Count Estimation | 23,261 | | Date of Issue | 2011-07-29 | | Date of Implementation | 2011-12-01 | | Quoted Standard | GB/T 2624.1-2006; GB/T 2624.2-2006; GB/T 2624.3-2006; GB/T 2624.4-2006; GB/T 17611 | | Adopted Standard | ISO 2186-2007, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 12 of 2011 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the time between the device and the second device the pressure signal transmission system design, layout and installation. By the pressure signal transmission system, using known techniques, measuring a fluid flow from the apparatus to safely transmit a pressure signal to the secondary device, and the signal value is not distorted or changed. |
GB/T 26801-2011: Fluid flow in closed conduits -- Connections for pressure signal transmissions between primary and secondary elements ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fluid flow in closed conduits. Connections for pressure signal transmissions between primary and secondary elements
ICS 17.120.10
N12
National Standards of People's Republic of China
Enclosed measuring fluid flow in the pipeline
Means between the primary and the secondary device
Connection of pressure signal transmission
(ISO 2186.2007, IDT)
Issued on. 2011-07-29
2011-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 1 General
4.1 Safety seal 1
4.2 pipe size 2
4.3 isolation valve (valve) 2
4.4 Manifold 3
4.5 Installation 4
4.6 taps 4
Size 4.7 Impulse tube 4
4.8 Insulation 5
5 5 horizontal pipe installation
5.1 Gas 5
5.2 liquid 5
5.3 condensed steam, such as water vapor 5
6 vertical pipe installation 6
6.1 General 6
6.2 Gas 6
6.3 Liquid 6
6.4 condensed steam, such as steam 6
7 grading ring 7
8 7 special case
Appendix A (informative) long connecting pipe diameter 8 Select Guide
Annex B (informative) Impulse control of dynamic characteristics 9
Annex C (informative) head height calculation example 10
Annex D (informative) Supplementary legend 11
References 18
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses the translation method identical with ISO 2186.2007 "Measurement of fluid flow in closed conduits primary device and the secondary device
Pressure between the transmitted signal connection method. "
This standard made the following editorial changes.
a) a reference to the original standard 5.1 and 5.2, the slope of the "8%" into a unified representation of the original reference standard Figure D.3, namely "1.12.5";
b) by deleting references to the original standard table A.1 title in parentheses, brackets put the contents of a table showing the top right of the unit taken, and deleted
Table A.1 "pressure signal is transmitted from the" bottom "mm" error representation;
c) a reference to the original standard table C.1, the values \u200b\u200blisted in the table by the lack of specific volume density values \u200b\u200bshown in the table, this is due to the specific volume given
Value due to insufficient number of significant digits. Contrast this standard capacitance values \u200b\u200bdid Correction. In 0.001001969m3/kg instead of
0.001002m3/kg; in 0.001004466m3/kg instead of 0.001004m3/kg.
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard was drafted. Shanghai Industrial Automation Instrument Research Institute, Shanghai Automation Instrumentation System Inspection and Testing Institute, Yuyao silver circulation
Instrument Co., Ltd., Naval Aviation devices metering station.
The main drafters of this standard. Guo Aihua, Zhu Jiashun, Zhao Yiqian, Gushun Feng.
Enclosed measuring fluid flow in the pipeline
Means between the primary and the secondary device
Connection of pressure signal transmission
1 Scope
This standard specifies the means between the primary and the secondary device pressure signal transmission system design, layout and installation. By pressure signal transmission
Delivery system, using known techniques of fluid flow measuring a pressure signal from the device safely transferred to a secondary device, and the signal will not
Distorted or changed.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2624.1-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 1. General
Principles and requirements (ISO 5167-1.2003, IDT)
GB/T 2624.2-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 2. Orifice
(ISO 5167-2.2003, IDT)
GB/T 2624.3-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 3. Nozzle
Venturi nozzles (ISO 5167-3.2003, IDT)
GB/T 2624.4-2006 with the differential pressure measuring device mounted to round pipe full pipe fluid flow - Part 4. Venturi
Tubes (ISO 5167-4.2003, IDT)
GB/T 17611 in closed conduits measuring fluid flow terms and symbols (GB/T 17611-1998, ISO 4006.1991,
IDT)
3 Terms and Definitions
GB/T 17611 and GB/T 2624.1 and define the following terms and definitions apply to this document.
3.1
Secondary means secondarydevice
Receiving a pressure signal from the device, and can display the differential pressure signal into a different form, such as a digital signal or an analog signal
Number, and then transferred to the differential pressure device according to another place.
4 General
4.1 Safety seal
Differential pressure signal to be transmitted through a pipe or hose securely to the secondary device. This requires a secure seal between the primary and the secondary device means
Fluid. Safety sealing fluid required to meet the applicable standards and regulations, the need to use a suitable structural materials, production methods, washers and password
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 26801-2011_English be delivered?Answer: Upon your order, we will start to translate GB/T 26801-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 26801-2011_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 26801-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|