US$489.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 26343-2010: Technical standard for physical examination for students Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 26343-2010 | English | 489 |
Add to Cart
|
4 days [Need to translate]
|
Technical standard for physical examination for students
| Valid |
GB/T 26343-2010
|
PDF similar to GB/T 26343-2010
Basic data Standard ID | GB/T 26343-2010 (GB/T26343-2010) | Description (Translated English) | Technical standard for physical examination for students | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | C56 | Classification of International Standard | 13.100 | Word Count Estimation | 21,294 | Date of Issue | 2011-01-14 | Date of Implementation | 2011-05-01 | Quoted Standard | GB/T 11533; GB/T 16133; WS/T 202; WS288 | Regulation (derived from) | National Standard Approval Announcement 2011 No.121 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the students form, physiological functions, ENT, surgery, technical requirements for medical and laboratory parameters. This standard applies to ordinary schools, vocational high school and technical school students' health checks, colleges and universities may also refer students to perform health checks. |
GB/T 26343-2010: Technical standard for physical examination for students---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical standard for physical examination for students
ICS 13.100
C56
National Standards of People's Republic of China
Student Health Check Technical Specification
Issued on. 2011-01-14
2011-05-01 implementation
People's Republic of China Ministry of Health
Standardization Administration of China released
Foreword
The Standard Appendix A, Appendix B, Appendix C is a normative appendix.
This standard is proposed and administered by the People's Republic of China Ministry of Health.
This standard by the People's Republic of China Ministry of Health is responsible for interpretation.
This standard was drafted. Hunan Provincial Disease Prevention and Control Center, the Shanghai Municipal Center for Disease Control and Prevention, Public Health, Anhui Medical University
Hospital, Hunan Provincial People's Hospital, Shenzhen Center for Disease Control.
The main drafters of this standard. Li Guangchun early Pengning Ning, Tao aryl standard, Liu Huilin, Liusi Qing, Chen Xue, Wang Cuilan.
Student Health Check Technical Specification
1 Scope
This standard specifies the student morphological, physiological functions, ENT, surgery, medical and technical requirements for laboratory parameters.
This standard applies to ordinary primary and secondary schools, vocational high school and technical school students health checks and colleges students may also refer to a health check
carried out.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 11533 standard vision chart
GB/T 16133 Children in screening abnormal curvature of the spine
WS/T 202 children and adolescents refractive testing requirements
WS288 tuberculosis diagnostic criteria
3 Configuration of measurement
3.1 Height
3.1.1 Equipment
Human altimeter.
0.00 proofread before use, and with a standard steel body correction tape altimeter scale, per meter error no larger than 0.1cm. At the same time, should
Check the column and base plate, column and vertical slide board is measured at the connection is tight, loose parts, etc., should be corrected promptly.
3.1.2 Method
Choose flat against the wall of the ground horizontal human altimeter, column scale facing the light source. Subject barefoot, standing in attention position
Humans altimeter floor, two upper limbs drooping naturally, heels together, toes separated into 60 °, chest and abdomen, head upright, eyes flat front view
Side, under the eyes and ears on the edge of the edge of the screen horizontal position between the heel, sacral and two three-point contact with scapular region column. Inspectors are standing on the
The right side of the subject, the slide plate measured along the column fell gently until contact with the cranial vertex. Binocular testing personnel should be high when the readings measured with the slide plate. Measurement
The amount of error should not exceed ± 0.5cm.
3.1.3 Results Recording
Recorded in centimeters, after reading to one decimal place.
3.1.4 Precautions
a) measuring slide plate in contact with the cranial vertex, elastic moderate. Head of braids, hair knot should untie, accessories should be removed.
B) After completion of the measurement, should be measured immediately slide plate to the highest point, to avoid the subject of other accident trauma.
3.2 Weight
3.2.1 Equipment
Lever or portable electronic scales weighing meter.
Before use to test its accuracy and sensitivity, calibration with standard weight 50kg and 0.1kg accuracy requirements of error of less than
0.1%, the sensitivity should be able to detect 0.1kg, below standard should be replaced.
3.2.2 Method
The scales on a flat, hard surface. Male students to wear shorts and female students to wear shorts, tank tops, countertops central standing scales. Use bars
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 26343-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 26343-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 26343-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 26343-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|