HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 24991-2010 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 24991-2010: Paper, board and pulps -- Determination of lead content -- Graphite furnace atomic absorption spectrometry method
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 24991-2010English209 Add to Cart 3 days [Need to translate] Paper, board and pulps -- Determination of lead content -- Graphite furnace atomic absorption spectrometry method Valid GB/T 24991-2010

PDF similar to GB/T 24991-2010


Standard similar to GB/T 24991-2010

GB/T 24328.3   GB/T 27741   GB/T 31905   GB/T 24988   GB/T 24999   GB/T 24990   

Basic data

Standard ID GB/T 24991-2010 (GB/T24991-2010)
Description (Translated English) Paper, board and pulps -- Determination of lead content -- Graphite furnace atomic absorption spectrometry method
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y30
Classification of International Standard 85-010
Word Count Estimation 9,985
Date of Issue 2010-08-09
Date of Implementation 2010-12-01
Quoted Standard GB/T 450; GB/T 462; GB/T 740; GB/T 6682
Regulation (derived from) National Standard Approval Announcement 2010 No.3 (Total No.158)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the graphite furnace atomic absorption spectrometry paper, paperboard and pulp methods lead content. This standard applies to a variety of available nitrate wet digestion, including pulp containing recycled fibers, including, paper and paperboard.

GB/T 24991-2010: Paper, board and pulps -- Determination of lead content -- Graphite furnace atomic absorption spectrometry method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Paper, board and pulps. Determination of lead content. Graphite furnace atomic absorption spectrometry method ICS 85-010 Y30 National Standards of People's Republic of China Paper, board and pulp lead content Graphite Furnace Atomic Absorption Spectrometry Paper, boardandpulps-Determinationofleadcontent- Issued on. 2010-08-09 2010-12-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

The Standard Appendix A, Appendix B is an informative annex. The standard proposed by China National Light Industry Council. The standard paper by the National Standardization Technical Committee (SAC/TC141) centralized. This standard was drafted. SZCIQ Industrial Testing Center, China Pulp and Paper Research Institute, Shenzhen test Quarantine Science Research Institute. The main drafters of this standard. Xu Rong, Chen Xuhui, Guhao Fei, Chen Xiangyang, Yi Feng. Paper, board and pulp lead content Graphite Furnace Atomic Absorption Spectrometry

1 Scope

This standard specifies the graphite furnace atomic absorption spectrometry paper, board and pulp lead content. This standard applies to all kinds of wet nitric acid is available, including those containing recycled fiber, including pulp, paper and paperboard. The detection limit of this method was about 60μg/kg.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 450 and take samples to an aspect of paper and paperboard samples, positive and negative determination (GB/T 450-2008, ISO 186. 2002, MOD) GB/T 462 paper, board and pulp - Determination of water sample (GB/T 462-2008; ISO 287. 1985, MOD; ISO 638. 1978, MOD) GB/T 740 pulp samples taken (GB/T 740-2003, ISO 7213. 1981, IDT) GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD) Principle 3 In a closed container, with nitric acid at high temperature and pressure conditions of the sample, diluted to give the sample, standard addition method using graphite furnace Determination of lead content by atomic absorption.

4 Reagents

Unless otherwise indicated, used in the analysis confirmed only for the gifted class pure reagents. 4.1 Water, GB/T 6682, Grade 2. 4.2 Concentrated nitric acid (HNO3), ρ = 1.40g/mL, the mass fraction is 65% to 68%. 4.3 Hydrogen peroxide (H2O2), ρ = 1.11g/mL, the mass fraction of ≥30%. 4.4 matrix modifiers. the selection of the matrix modifier may be determined by a blank test, we recommend the following matrix modifier. 4.4.1 palladium nitrate stock solution, 0.4%, taking 2.0g of Pd (NO3) 2 was dissolved in 10mL of concentrated nitric acid (4.2), and then washed with water in capacity Bottle diluted to 500mL. Valid for six months. 4.4.2 Work palladium nitrate solution, 200mg/L, taking 5mL palladium nitrate stock solution (4.4.1), dilute with water to 100mL. That solution with Ready to use. 4.4.3 ammonium dihydrogen phosphate magnesium nitrate solution, 1% 0.06%, taking 1.0g of NH4H2PO4 and 0.06g of Mg (NO3) 2 · 6H2O was dissolved in water and diluted to 100mL. With a solution that is ready to use. 4.5 lead standard stock solution, 100mg/L, weighed 0.1598g lead nitrate [Pb (NO3) 2] in a beaker, add a little water, then add After 20mL of concentrated nitric acid (4.2) were dissolved, diluted with water to 1L. Solution was kept in a sealed polyethylene container. Valid for six months.

5 Instruments

Conventional laboratory equipment and the following.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 24991-2010_English be delivered?

Answer: Upon your order, we will start to translate GB/T 24991-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 24991-2010_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 24991-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.