Basic data | Standard ID | GB/T 24922-2010 (GB/T24922-2010) | | Description (Translated English) | Technical specifications of explosion-proof version electric valve actuators | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | J16 | | Classification of International Standard | 23.060.99 | | Word Count Estimation | 6,690 | | Date of Issue | 2010-08-09 | | Date of Implementation | 2010-12-31 | | Quoted Standard | GB 3836.1-2000; GB 3836.2-2000; GB 3836.3-2000; GB 4208-2008; GB/T 24923-2010; JB/T 8670-1997 | | Regulation (derived from) | National Standard Approval Announcement 2010 No.3 (Total No.158) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the flameproof electric valve actuators (hereinafter referred to as explosion-proof electric apparatus) terms and definitions, technical requirements, test methods, inspection rules face, signs, packaging and storage. This standard applies to proof type of d, category of II, an explosive gas mixture of A, B, C three, allowing the maximum surface temperature of 85��C (T6) ~ 135��C (T4) electric device design, manufacturing and inspection. |
GB/T 24922-2010: Technical specifications of explosion-proof version electric valve actuators---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Technical specifications of explosion-proof version electric valve actuators
ICS 23.060.99
J16
National Standards of People's Republic of China
Flameproof electric valve actuators technical conditions
Posted 2009-08-09
2010-12-31 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The standard proposed by China Machinery Industry Federation.
The standard valve by the National Standardization Technical Committee (SAC/TC188) centralized.
This standard is mainly drafted by. Hefei General Machinery Research Institute, Tianjin Baili Machinery Co., Ltd., located in Tianjin Ai Kete valve control
Preparation Co., Ltd., China Teflon Group, Huangshan Liang industry Valve Co., Ltd., Yangzhou Power Equipment built factory, Changzhou Power Station Auxiliary Equipment
Plant Limited.
The main drafters of this standard. Huang Minya, Wang Lei, Cao record type, Lijin Shuo, Liu Huaifu, item Megan, Zhule Yao Jiang New Year, Chen Huaxiang,
ZHAO.
Flameproof electric valve actuators technical conditions
1 Scope
This standard specifies the flameproof electric valve actuators (hereinafter referred to as explosion-proof electric apparatus) terms and definitions, technical requirements, test side
Method, inspection rules, marking, packaging and storage.
This standard applies to the type of protection is d, category Ⅱ class, explosive gas mixture A, B, C three, maximum allowable surface temperature
Design of electrical installations 85 ℃ (T6) ~ 135 ℃ (T4), manufacturing and testing.
2 References
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB 3836.1-2000 Electrical equipment for explosive gas atmospheres - Part 1. General requirements (eqv IEC 60079-0.1998)
GB 3836.2-2000 Electrical apparatus for explosive gas atmospheres - Part 2. flameproof "d" (eqv IEC 60079-1.1990)
GB 3836.3-2000 Electrical equipment for explosive gas atmospheres Part 3. Increased Safety "e" (eqv IEC 60079-7.1990)
GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT)
GB/T 24923-2010 common type valve electric device technology
JB/T 8670-1997 YBDF2 series of electric valve actuators induction motors for explosion-proof three-phase
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
Explosion-proof type typeofprotection
Specific measures taken to protect electrical equipment from causing ignition of a surrounding explosive atmosphere taken.
3.2
Explosive atmosphere potentialyexplosiveatmosphere
Explosive atmospheres may occur.
3.3
Explosive gas atmospheres explosivegasatmosphere
Under atmospheric conditions, the mixture of air and combustible material gas, vapor or mist formed, the mixture is ignited, the combustion will spread
Environmental entire unburned mixture.
3.4
Flameproof enclosure flameproofenclosure
One kind of type of protection for electrical equipment. Penetrate the shell can withstand any joints or structural gap to the interior of the housing shell can
Combustible mixture in an internal explosion without damage, and does not cause the outer one of a variety of gases or vapors to ignite an explosive atmosphere formed.
3.5
Flameproof joint flameproofjoint
Flameproof enclosure surface corresponding to the different parts fit together (or shell connections) and the flame or the products of combustion from the outside may thus
Reached the interior of the shell portion outside the housing.
|