US$299.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24916-2010: Surface treatment solution -- Determination of metal element contents -- Inductively coupled plasma atomic emission spectrometric method Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24916-2010 | English | 299 |
Add to Cart
|
3 days [Need to translate]
|
Surface treatment solution -- Determination of metal element contents -- Inductively coupled plasma atomic emission spectrometric method
| Valid |
GB/T 24916-2010
|
PDF similar to GB/T 24916-2010
Basic data | Standard ID | GB/T 24916-2010 (GB/T24916-2010) | | Description (Translated English) | Surface treatment solution -- Determination of metal element contents -- Inductively coupled plasma atomic emission spectrometric method | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | A29 | | Classification of International Standard | 25.220.40 | | Word Count Estimation | 13,174 | | Date of Issue | 2010-08-09 | | Date of Implementation | 2010-12-31 | | Quoted Standard | GB/T 6682 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 3, 2010 (No. 158 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the inductively coupled plasma atomic emission spectrometry surface treatment of metals in solution methods. This standard applies to the aluminum surface treatment solution, sodium, calcium, magnesium, iron, copper, chromium, lead, zinc, manganese, nickel, antimony and other metals content. |
GB/T 24916-2010: Surface treatment solution -- Determination of metal element contents -- Inductively coupled plasma atomic emission spectrometric method ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Surface treatment solution. Determination of metal element contents. Inductively coupled plasma atomic emission spectrometric method
ICS 25.220.40
A29
National Standards of People's Republic of China
Determination of metals in the solution of the surface treatment
Inductively coupled plasma atomic emission spectrometry
Issued on. 2010-08-09
2010-12-31 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Principle 1
4 Reagents and materials 1
5 Preparation 2
5.1 Preparation of standard solution 2
5.2 standard addition method of preparation of standard solution series 3
6 Analysis of Condition 5
7 Procedure 5
5 7.1 blank test
Pre-treatment and analysis Preparation 5 7.2 test solution
7.3 Determination of 8
8 8 Calculation Results
8.1 Calculation 8
Precision 8 8.2
8 9 Test report
10 Note 9
Foreword
The standard proposed by China Machinery Industry Federation.
This standard by the national metal and non-metal coating layer Standardization Technical Committee centralized.
This standard was drafted. Chongqing Changan Automobile Company Limited.
The main drafters of this standard. Huang Xianming, Zhang Jian Yang, Li Qihua, Yang Xuemei, Fanzhao Ying, Zhu Jun.
Determination of metals in the solution of the surface treatment
Inductively coupled plasma atomic emission spectrometry
1 Scope
This standard specifies the inductively coupled plasma atomic method for determining the surface treatment of metals in solution and emission spectroscopy.
This standard applies to the determination of the surface of aluminum in the solution, sodium, calcium, magnesium, iron, copper, chromium, lead, zinc, manganese, nickel, antimony and other metals in processing.
Determination of the range in Table 1.
Table 1 Measuring range
Element Measuring range/(g/L) element Measuring range/(g/L) element Measuring range/(g/L)
Sodium aluminum 0.000020 0.000016 to 5.00 to 5.00 to 5.00 calcium 0.000010
Magnesium iron 0.000010 0.000010 to 5.00 to 20.00 to 20.00 Copper 0.000010
Chromium lead 0.000040 0.000020 to 5.00 to 5.00 to 5.00 Zinc 0.000010
Nickel-manganese to 5.00 0.000010 0.000020 0.000060 to 5.00 to 5.00 antimony
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3696. 1987, MOD)
Principle 3
Sample of nitric acid and hydrogen peroxide to remove organic thermal decomposition by perchloric acid smoke treated, acidified with hydrochloric acid, the sample solution is evaporated
And excitation and emission light elements contained in the characteristic wavelength, after splitting splitting system, its spectral intensity accepted by the photovoltaic element and into telecommunications
Number is recorded, according to the relationship element concentrations and spectral intensity, determination of each element. Determination of the standard addition method.
4 Reagents and materials
Unless otherwise indicated in the analysis using only analytical reagent.
4.1 argon, w (Ar) ≥99.99%.
4.2 water, in line with GB/T 6682 in two water specifications.
4.3 aluminum, w (Al) ≥99.95%.
4.4 Working Standard reagent sodium chloride as a solid.
4.5 calcium carbonate, w (CaCO3) ≥99.95%.
Magnesium 4.6, w (Mg) ≥99.95%.
4.7 iron, w (Fe) ≥99.95%.
4.8 Cu, w (Cu) ≥99.95%.
4.9 Cr, w (Cr) ≥99.95%.
4.10 Pb, w (Pb) ≥99.95%.
4.11 Zinc, w (Zn) ≥99.95%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24916-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 24916-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24916-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24916-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|