US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23951-2009: Inorganic chemicals for industrial use -- General method for the determination of residue after ignition Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 23951-2009 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Inorganic chemicals for industrial use -- General method for the determination of residue after ignition
| Valid |
GB/T 23951-2009
|
PDF similar to GB/T 23951-2009
Basic data Standard ID | GB/T 23951-2009 (GB/T23951-2009) | Description (Translated English) | Inorganic chemicals for industrial use -- General method for the determination of residue after ignition | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G10 | Classification of International Standard | 71.060.01 | Word Count Estimation | 8,840 | Date of Issue | 2009-06-02 | Date of Implementation | 2010-02-01 | Quoted Standard | GB/T 6682-2008 | Regulation (derived from) | National Standard Approval Announcement 2009 No.8 (Total No.148) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the inorganic chemical products used Gravimetric method common method of burning residue feed, analysis step, calculated results. This standard applies to be able to sublimate or carbonation and measured at 55 ~ 1200��C Residue on ignition inorganic chemical products except the body of the net. |
GB/T 23951-2009: Inorganic chemicals for industrial use -- General method for the determination of residue after ignition ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inorganic chemicals for industrial use. General method for the determination of residue after ignition
ICS 71.060.01
G10
National Standards of People's Republic of China
Inorganic chemical products
General method for the determination of residue on ignition
Posted 2009-06-02
2010-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee chemical inorganic chemicals Club (SAC/TC63/SC1) centralized.
This standard is mainly drafted by. Fluoride Chemicals Co., Ltd., CNOOC Tianjin Chemical Research & Design Institute.
The main drafters of this standard. Xu Jin Xue, BU Law See Gao Peng.
This standard is the first release.
Inorganic chemical products
General method for the determination of residue on ignition
1 Scope
This standard specifies the inorganic chemical products by Gravimetric general method of residue on ignition method summary, the analysis step, the results
Calculations.
This standard applies to be able to sublimate or carbonized and at 550 ℃ ~ 1200 ℃ In addition to inorganic chemical products net residue on ignition of the main body
Determination.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 6682-2008 analytical laboratory use specifications and test methods (ISO 3696. 1987, MOD)
3 Method summary
The use of a volatile sample is formed between the body and the residue material differences between the physical and chemical properties of thermal stability and oxygen, etc.,
The samples were low-temperature heating evaporation, carbonation, high temperature burning, the sample body and the residue was completely separated, said the quality of the residue.
4 Safety Tips
Sulfuric acid or hydrochloric acid used in this test method is corrosive, be careful when operating! As splashed on the skin should immediately wash with water,
In severe cases should be treated immediately. This test method need to use high-temperature furnace, the operation must be careful to prevent burns.
5 General Provisions
This standard reagents and water, did not indicate when the other requirements, refer to analytically pure reagents and GB/T 6682-2008 stipulated three
Grade water.
6 Reagents
Hydrochloric acid solution was 6.1. 1 + 1.
6.2 sulfuric acid.
7 instruments and equipment
7.1 evaporation vessel. crucible or evaporating dish, made of platinum, quartz or ceramics.
7.2 high-temperature furnace. temperature can be controlled at 550 ℃ ~ 1200 ℃. 550 ℃ ~ 800 ℃, the temperature can be controlled at 550 ℃ ± 25 ℃ ~ 800 ℃
± 25 ℃; 800 ℃ ~ 1200 ℃, the temperature can be controlled at 800 ℃ ± 50 ℃ ~ 1200 ℃ ± 50 ℃.
Analysis Step 8
8.1 ignition temperature selection
The sample own characteristics, select the appropriate firing temperature.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23951-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 23951-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 23951-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23951-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|