US$949.00 · In stock Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23753-2020: (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above) Status: Valid GB/T 23753: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 23753-2020 | English | 949 |
Add to Cart
|
7 days [Need to translate]
|
(Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above)
| Valid |
GB/T 23753-2020
|
GB/T 23753-2009 | English | 639 |
Add to Cart
|
3 days [Need to translate]
|
Specification and technical requirements for 330kV and 500kV oil-immersed shunt reactors
| Obsolete |
GB/T 23753-2009
|
PDF similar to GB/T 23753-2020
Basic data Standard ID | GB/T 23753-2020 (GB/T23753-2020) | Description (Translated English) | (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above) | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | K41 | Word Count Estimation | 51,557 | Date of Issue | 2020-11-19 | Date of Implementation | 2021-06-01 | Older Standard (superseded by this standard) | GB/T 23753-2009 | Regulation (derived from) | National Standard Announcement No. 26 of 2020 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 23753-2020: (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above) ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above)
ICS 29.180
K41
National Standards of People's Republic of China
Replace GB/T 23753-2009
110kV and above oil-immersed shunt reactor
Technical parameters and requirements
shuntreactors
2020-11-19 released
2021-06-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Table of contents
Preface Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Conditions of use 2
5 110kV class reactor 2
6 220kV class reactor 8
7 330kV class reactor 14
8 500kV class reactor 20
9 750kV class reactor 26
10 1000kV class reactor 32
11 Marking, lifting, packaging, transportation and storage 40
Appendix A (Normative Appendix) The technical parameters and technical parameters of neutral grounding reactors for 110kV and above oil-immersed shunt reactors
Requirements 41
Figure 1 IVPD test sequence of 1000kV oil-immersed shunt reactor 38
Figure 2 Partial discharge measurement test sequence at the end of 1000kV oil-immersed shunt reactor (neutral point) 39
Table 1 Basic parameters of 110kV single-phase reactor 2
Table 2 Basic parameters of 110kV three-phase reactor 3
Table 3 Overexcitation capacity of 110kV reactor 4
Table 4 Rated insulation level of 110kV class reactor 5
Table 5 Basic parameters of 220kV single-phase reactor 8
Table 6 Basic parameters of 220kV three-phase reactor 9
Table 7 Overexcitation capacity of 220kV class reactor 10
Table 8 Rated insulation level of 220kV class reactor 11
Table 9 Basic parameters of 330kV single-phase reactor 14
Table 10 Basic parameters of 330kV three-phase reactor 15
Table 11 Overexcitation capacity of 330kV reactor 17
Table 12 Rated insulation level of 330kV reactor 17
Table 13 Basic parameters of 500kV single-phase reactor 20
Table 14 Overexcitation capacity of 500kV reactor 22
Table 15 Rated insulation level of 500kV class reactor 23
Table 16 Basic parameters of 750kV single-phase reactor 26
Table 17 Tank vibration level of 750kV reactor 28
Table 18 Overexcitation capability of 750kV reactor 28
Table 19 Rated insulation level of 750kV reactor 29
Table 20 Basic parameters of 1000kV single-phase reactor 32
Table 21 Tank vibration level of 1000kV class reactor 33
Table 22 Overexcitation capacity of 1000kV class reactor 34
Table 23 Rated insulation level of 1000kV class reactor 34
Table 24 Rated insulation level of 1000kV bushing 36
Table 25 Terminal allowable load of 1000kV bushing 36
Table A.1 110kV, 220kV, 330kV, 500kV class shunt reactor matching neutral point grounding reactor rated insulation level 42
Table A.2 Rated insulation level of neutral grounding reactor for 750kV parallel reactor
Table A.3 Rated insulation level of neutral grounding reactor for 1000kV class shunt reactor 46
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 23753-2009 "330kV and 500kV oil-immersed shunt reactor technical parameters and requirements", and
Compared with GB/T 23753-2009, the main technical changes are as follows.
---Expanded the scope of application of the standard (see Chapter 1, Chapter 1 of the.2009 edition);
---Modified the normative references (see Chapter 2, Chapter 2 of the.2009 edition);
---Added the conditions of use (see Chapter 4);
---Modified the technical content of 330kV and 500kV (see Chapter 7 and Chapter 8, Chapter 4 ~ Chapter 8 of the.2009 edition
chapter);
---The technical parameters and requirements of 110kV, 220kV, 750kV and 1000kV oil-immersed shunt reactors have been added (see Chapter 5,
Chapter 6, Chapter 9, and Chapter 10);
--- The content of the appendix has been modified and supplemented (see Appendix A, Appendix A of the.2009 edition).
This standard was proposed by China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Transformer Standardization Technical Committee (SAC/TC44).
Drafting organizations of this standard. Shenyang Transformer Research Institute Co., Ltd., Xi'an Xidian Transformer Co., Ltd., Wujiang Transformer
Co., Ltd., China Electric Power Research Institute Co., Ltd., Baoding Tianwei Baobian Electric Co., Ltd., TBEA Shenyang Transformer Group
Co., Ltd., China Southern Power Grid Research Institute Co., Ltd., TBEA Hengyang Transformer Co., Ltd., Shandong Power Transmission Equipment Co., Ltd.,
Electric Power Research Institute of Guangdong Power Grid Co., Ltd., Jiangsu Huapeng Transformer Co., Ltd., State Grid Shaanxi Electric Power Company
Institute, Zhejiang Jiangshan Transformer Co., Ltd.
The main drafters of this standard. Zhang Zhongguo, Chen Rong, Yu Yunchang, Zhang Xianzhong, Fu Chao, Zhang Dong, Liu Junfei, Lei Yuanyuan, Gong Xiaoqi, Li Xuecheng,
Lin Chunyao, Zhao Wenjun, Liu Xiaowei, Jiang Zhenjun.
The previous versions of the standard replaced by this standard are as follows.
---GB/T 23753-2009.
110kV and above oil-immersed shunt reactor
Technical parameters and requirements
1 Scope
This standard specifies the terms and definitions of oil-immersed shunt reactors (hereinafter referred to as reactors) with a nominal voltage of 110kV and above.
Definition, use conditions, performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation and storage. Unify
The performance parameters, technical requirements, design and structure of neutral point grounding reactors for 110kV and above oil-immersed shunt reactors have been determined.
Inspection rules and methods, marking, lifting, packaging, transportation and storage.
This standard applies to single-phase and three-phase oil-immersed shunt reactors with a rated frequency of 50 Hz and a system nominal voltage of 110 kV and above
The neutral grounding reactor is matched with 110kV and above oil-immersed shunt reactor.
For reactors with special requirements, such as capacitor-adjusting reactors, if the rated impedance has a ±5% or ±10% tap, it is opened through a non-excitation tap
To realize the adjustment of reactor capacity, its technical requirements can be used as reference.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 1094.1 Power Transformer Part 1.General Rules
GB/T 1094.2 Power Transformer Part 2.Temperature Rise of Liquid-immersed Transformer
GB/T 1094.3 Power Transformer Part 3.Insulation Level, Insulation Test and External Insulation Air Gap
GB/T 1094.6 Power Transformer Part 6.Reactor
GB/T 1094.10 Power Transformer Part 10.Sound Level Measurement
GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches
GB/T 2900.95 Electrotechnical terminology transformer, voltage regulator and reactor
GB/T 4109 Insulating bushing with AC voltage higher than 1000V
GB/T 5273 Standardization of terminal size for high voltage electrical appliances
GB/T 11604 High-voltage electrical equipment radio interference test method
GB/T 20840.2 Transformer Part 2.Supplementary Technical Requirements for Current Transformers
GB/T 26218.2 Selection and size determination of high-voltage insulators used under dirty conditions Part 2.Porcelain and glass for AC systems
Glass insulator
DL/T 722 Dissolved gas analysis and judgment guidelines in transformer oil
3 Terms and definitions
The terms and definitions defined in GB/T 1094.6 and GB/T 2900.95 apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23753-2020_English be delivered?Answer: Upon your order, we will start to translate GB/T 23753-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 23753-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23753-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 23753-2020?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23753-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|