HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 23753-2020 English PDF

US$949.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 23753-2020: (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above)
Status: Valid

GB/T 23753: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 23753-2020English949 Add to Cart 7 days [Need to translate] (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above) Valid GB/T 23753-2020
GB/T 23753-2009English639 Add to Cart 3 days [Need to translate] Specification and technical requirements for 330kV and 500kV oil-immersed shunt reactors Obsolete GB/T 23753-2009

PDF similar to GB/T 23753-2020


Standard similar to GB/T 23753-2020

GB/T 19212.5   GB/T 10228   GB/T 8286   GB/T 19212.14   GB/T 23755   

Basic data

Standard ID GB/T 23753-2020 (GB/T23753-2020)
Description (Translated English) (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K41
Word Count Estimation 51,557
Date of Issue 2020-11-19
Date of Implementation 2021-06-01
Older Standard (superseded by this standard) GB/T 23753-2009
Regulation (derived from) National Standard Announcement No. 26 of 2020
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 23753-2020: (Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Technical parameters and requirements for oil-immersed shunt reactors of 110kV and above) ICS 29.180 K41 National Standards of People's Republic of China Replace GB/T 23753-2009 110kV and above oil-immersed shunt reactor Technical parameters and requirements shuntreactors 2020-11-19 released 2021-06-01 implementation State Administration for Market Regulation Issued by the National Standardization Management Committee

Table of contents

Preface Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Conditions of use 2 5 110kV class reactor 2 6 220kV class reactor 8 7 330kV class reactor 14 8 500kV class reactor 20 9 750kV class reactor 26 10 1000kV class reactor 32 11 Marking, lifting, packaging, transportation and storage 40 Appendix A (Normative Appendix) The technical parameters and technical parameters of neutral grounding reactors for 110kV and above oil-immersed shunt reactors Requirements 41 Figure 1 IVPD test sequence of 1000kV oil-immersed shunt reactor 38 Figure 2 Partial discharge measurement test sequence at the end of 1000kV oil-immersed shunt reactor (neutral point) 39 Table 1 Basic parameters of 110kV single-phase reactor 2 Table 2 Basic parameters of 110kV three-phase reactor 3 Table 3 Overexcitation capacity of 110kV reactor 4 Table 4 Rated insulation level of 110kV class reactor 5 Table 5 Basic parameters of 220kV single-phase reactor 8 Table 6 Basic parameters of 220kV three-phase reactor 9 Table 7 Overexcitation capacity of 220kV class reactor 10 Table 8 Rated insulation level of 220kV class reactor 11 Table 9 Basic parameters of 330kV single-phase reactor 14 Table 10 Basic parameters of 330kV three-phase reactor 15 Table 11 Overexcitation capacity of 330kV reactor 17 Table 12 Rated insulation level of 330kV reactor 17 Table 13 Basic parameters of 500kV single-phase reactor 20 Table 14 Overexcitation capacity of 500kV reactor 22 Table 15 Rated insulation level of 500kV class reactor 23 Table 16 Basic parameters of 750kV single-phase reactor 26 Table 17 Tank vibration level of 750kV reactor 28 Table 18 Overexcitation capability of 750kV reactor 28 Table 19 Rated insulation level of 750kV reactor 29 Table 20 Basic parameters of 1000kV single-phase reactor 32 Table 21 Tank vibration level of 1000kV class reactor 33 Table 22 Overexcitation capacity of 1000kV class reactor 34 Table 23 Rated insulation level of 1000kV class reactor 34 Table 24 Rated insulation level of 1000kV bushing 36 Table 25 Terminal allowable load of 1000kV bushing 36 Table A.1 110kV, 220kV, 330kV, 500kV class shunt reactor matching neutral point grounding reactor rated insulation level 42 Table A.2 Rated insulation level of neutral grounding reactor for 750kV parallel reactor Table A.3 Rated insulation level of neutral grounding reactor for 1000kV class shunt reactor 46

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces GB/T 23753-2009 "330kV and 500kV oil-immersed shunt reactor technical parameters and requirements", and Compared with GB/T 23753-2009, the main technical changes are as follows. ---Expanded the scope of application of the standard (see Chapter 1, Chapter 1 of the.2009 edition); ---Modified the normative references (see Chapter 2, Chapter 2 of the.2009 edition); ---Added the conditions of use (see Chapter 4); ---Modified the technical content of 330kV and 500kV (see Chapter 7 and Chapter 8, Chapter 4 ~ Chapter 8 of the.2009 edition chapter); ---The technical parameters and requirements of 110kV, 220kV, 750kV and 1000kV oil-immersed shunt reactors have been added (see Chapter 5, Chapter 6, Chapter 9, and Chapter 10); --- The content of the appendix has been modified and supplemented (see Appendix A, Appendix A of the.2009 edition). This standard was proposed by China Electrical Equipment Industry Association. This standard is under the jurisdiction of the National Transformer Standardization Technical Committee (SAC/TC44). Drafting organizations of this standard. Shenyang Transformer Research Institute Co., Ltd., Xi'an Xidian Transformer Co., Ltd., Wujiang Transformer Co., Ltd., China Electric Power Research Institute Co., Ltd., Baoding Tianwei Baobian Electric Co., Ltd., TBEA Shenyang Transformer Group Co., Ltd., China Southern Power Grid Research Institute Co., Ltd., TBEA Hengyang Transformer Co., Ltd., Shandong Power Transmission Equipment Co., Ltd., Electric Power Research Institute of Guangdong Power Grid Co., Ltd., Jiangsu Huapeng Transformer Co., Ltd., State Grid Shaanxi Electric Power Company Institute, Zhejiang Jiangshan Transformer Co., Ltd. The main drafters of this standard. Zhang Zhongguo, Chen Rong, Yu Yunchang, Zhang Xianzhong, Fu Chao, Zhang Dong, Liu Junfei, Lei Yuanyuan, Gong Xiaoqi, Li Xuecheng, Lin Chunyao, Zhao Wenjun, Liu Xiaowei, Jiang Zhenjun. The previous versions of the standard replaced by this standard are as follows. ---GB/T 23753-2009. 110kV and above oil-immersed shunt reactor Technical parameters and requirements

1 Scope

This standard specifies the terms and definitions of oil-immersed shunt reactors (hereinafter referred to as reactors) with a nominal voltage of 110kV and above. Definition, use conditions, performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation and storage. Unify The performance parameters, technical requirements, design and structure of neutral point grounding reactors for 110kV and above oil-immersed shunt reactors have been determined. Inspection rules and methods, marking, lifting, packaging, transportation and storage. This standard applies to single-phase and three-phase oil-immersed shunt reactors with a rated frequency of 50 Hz and a system nominal voltage of 110 kV and above The neutral grounding reactor is matched with 110kV and above oil-immersed shunt reactor. For reactors with special requirements, such as capacitor-adjusting reactors, if the rated impedance has a ±5% or ±10% tap, it is opened through a non-excitation tap To realize the adjustment of reactor capacity, its technical requirements can be used as reference.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 1094.1 Power Transformer Part 1.General Rules GB/T 1094.2 Power Transformer Part 2.Temperature Rise of Liquid-immersed Transformer GB/T 1094.3 Power Transformer Part 3.Insulation Level, Insulation Test and External Insulation Air Gap GB/T 1094.6 Power Transformer Part 6.Reactor GB/T 1094.10 Power Transformer Part 10.Sound Level Measurement GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches GB/T 2900.95 Electrotechnical terminology transformer, voltage regulator and reactor GB/T 4109 Insulating bushing with AC voltage higher than 1000V GB/T 5273 Standardization of terminal size for high voltage electrical appliances GB/T 11604 High-voltage electrical equipment radio interference test method GB/T 20840.2 Transformer Part 2.Supplementary Technical Requirements for Current Transformers GB/T 26218.2 Selection and size determination of high-voltage insulators used under dirty conditions Part 2.Porcelain and glass for AC systems Glass insulator DL/T 722 Dissolved gas analysis and judgment guidelines in transformer oil

3 Terms and definitions

The terms and definitions defined in GB/T 1094.6 and GB/T 2900.95 apply to this document.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 23753-2020_English be delivered?

Answer: Upon your order, we will start to translate GB/T 23753-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 23753-2020_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 23753-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 23753-2020?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23753-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.