HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (12 Oct 2025)

GB/T 2317.1-2008 English PDF

US$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 2317.1-2008: Test method for electric power fittings -- Part 1: Mechanical tests
Status: Valid

GB/T 2317.1: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 2317.1-2008English299 Add to Cart 3 days [Need to translate] Test method for electric power fittings -- Part 1: Mechanical tests Valid GB/T 2317.1-2008
GB/T 2317.1-2000English479 Add to Cart 4 days [Need to translate] Electric Power Fitting mechanical test methods Obsolete GB/T 2317.1-2000
GB/T 2317-1985EnglishRFQ ASK 3 days [Need to translate] Fittings acceptance inspection, test methods, marking and packing Obsolete GB/T 2317-1985

PDF similar to GB/T 2317.1-2008


Standard similar to GB/T 2317.1-2008

GB/T 2820.7   GB/T 2317.4   GB/T 2820.1   GB/T 30372   GB/T 2315   GB/T 11920   

Basic data

Standard ID GB/T 2317.1-2008 (GB/T2317.1-2008)
Description (Translated English) Test method for electric power fittings -- Part 1: Mechanical tests
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K51
Classification of International Standard 29.240.20
Word Count Estimation 13,140
Date of Issue 2008-09-24
Date of Implementation 2009-08-01
Older Standard (superseded by this standard) GB/T 2317.1-2000
Quoted Standard GB/T 2317.4; GB/T 8287.2; DL/T 763; DL/T 1098; DL/T 1099
Adopted Standard IEC 61284-1997, MOD
Regulation (derived from) Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the electrical fittings mechanical test methods. This section applies to the rated voltage of 10 kV and above overhead power lines, substations and power distribution equipment used in electrical fittings (hereinafter referred to as fittings).

GB/T 2317.1-2008: Test method for electric power fittings -- Part 1: Mechanical tests

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test method for electric power fittings Part 1. Mechanical tests ICS 29.240.20 K51 National Standards of People's Republic of China Replacing GB/T 2317.1-2000 Electrical fittings - Test methods - Part 1. Mechanical test (IEC 61284.1997, Overheadlines-Requirementsandtestsforfittings, MOD) Posted 2008-09-24 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Test category 1 5 connection fittings Test 2 6 Suspension Clamps Test 3 7 Clamp fittings and connecting test 5 Test 68 of preformed fittings 9 protection fittings Test 6 The contact fittings 10 Test 6 711 bus test of fittings

Foreword

GB/T 2317 "Test methods for electrical fittings" There are four parts, namely. GB/T 2317.1 electrical fittings - Test methods - Part 1. Mechanical test GB/T 2317.2 electrical fittings - Test methods - Part 2. corona and radio interference test GB/T 2317.3 electrical fittings - Test methods - Part 3. Thermal cycling test GB/T 2317.4 electrical fittings - Test methods - Part 4. Acceptance rules This part of GB/T 2317 Part 1. The partial modification using IEC 61284.1997 "Requirements and test overhead line fittings ---" and also consider the specific situation of China, An increase of preformed fittings mechanical test content. This section and the IEC 61284.1997 as compared to the following main differences. --- Increasing the bending and test methods busbar fittings equalizing shield gold with strength, with the gold contacts; --- Consider the specific situation of China, an increase of preformed fittings mechanical test content; Code such as the increase of the "connection fittings --- mechanical damage load and failure load test when. --- customary expression of modified LOADING exploded view. "For increasing load mode, this part of the narrative, and the IEC standard adopts the square icon formula; --- Label defined term is not exactly the same as in the IEC "specified minimum failure load" in this section as "nominal load damage Netherlands. " This Part replaces GB/T 2317.1-2000 "electrical fittings Mechanical test methods." This section compared with the GB/T 2317.1-2000, mainly with the following modifications. --- The definition of some of the terms have been adjusted to make the definition clearer definition; --- Original title of Chapter 4 standard "test specimen type and quantity" to "test category." Test-categories of "purpose" and "a General requirements "two to define, more clearly defined; --- Connection fittings and suspension clamps of "experimental arrangement" of the text has been substantially revised, the test arrangement described in more clear Chu easy to understand, but also with a corresponding portion of the IEC standards coincide; --- For the content of the suspension clamp connection hardware and the "Criteria" were substantially modified, no longer distinguish between type testing, sampling and test Routine tests, instead of a uniform criterion; 6.1 --- The title "load mechanical damage and mechanical failure load" to "mechanical load test"; --- Original standard 6.2.1 and 6.2.2 are combined content and add a test method to choose. This part is proposed by the China Electricity Council. The overhead lines in part by the National Standardization Technical Committee (SAC/TC202) centralized. This section is responsible for drafting unit. Beijing State Grid Electric Power Research Institute building. Participated in the drafting of this section. Nanjing Line Equipment Factory, Zhejiang Electric Power Design Institute. The main drafters of this section. Thin pass, Xunai tube, Dong-e Kat, Ning, Liu Changqing, You Zhuanyong, Zouchun Ning, Jing Dynasty, Zhou Lixian. This part of the standard replaces the previous editions are. --- GB/T 2317-1985, GB/T 2317.1-2000. Electrical fittings - Test methods - Part 1. Mechanical test

1 Scope

This section provides mechanical test methods for electrical fittings. This section applies to the rated voltage of 10kV and above overhead power lines, substations and distribution equipment used in power plant electrical fittings (hereinafter Referred fittings).

2 Normative references

The following documents contain provisions which, through reference to GB/T 2317 to the present, constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2317.4 electrical fittings acceptance marking and packaging rules GB/T 8287.2 High voltage post insulators Part 2. Dimensions and characteristics (GB/T 8287.2-1999, neqIEC 60273) DL/T 763 overhead lines Preformed fittings technical requirements DL/T 1098 spacer technical requirements and test methods DL/T 1099 Damper Technical conditions and test methods

3 Terms and Definitions

The following terms and definitions apply to this section. 3.1 Under specified test conditions, it can be applied to the gold with a maximum load. 3.2 Under test conditions, gold has not appeared permanent deformation under maximum load conditions can bear. 3.3 Presented by the demand side or the supply side by a predetermined minimum load of gold with no mechanical damage. 3.4 Some way of securing the wire fittings, upon application of a load, occurs between the wire and the relative displacement of the fittings, so that the test load can not When continue to rise, this phenomenon is called slip. 3.5 Fastening of wires required fittings, maximum load without slippage phenomenon can bear.

4 test category

4.1 Mechanical type tests 4.1.1 Objective Type test is to determine the mechanical design features, normally only once, and only in design, material or process change when redone.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 2317.1-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 2317.1-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 2317.1-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 2317.1-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 2317.1-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 2317.1-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.