US$369.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 23113-2023: Sample preparation for measurement of mercury level in discharge lamp Status: Valid GB/T 23113: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 23113-2023 | English | 369 |
Add to Cart
|
4 days [Need to translate]
|
Sample preparation for measurement of mercury level in discharge lamp
| Valid |
GB/T 23113-2023
|
| GB/T 23113-2017 | English | 639 |
Add to Cart
|
4 days [Need to translate]
|
Sample preparation for measurement of mercury level in fluorescent lamps
| Obsolete |
GB/T 23113-2017
|
| GB/T 23113-2008 | English | 559 |
Add to Cart
|
3 days [Need to translate]
|
Measurement of mercury level in fluorescent lamps
| Obsolete |
GB/T 23113-2008
|
PDF similar to GB/T 23113-2023
Basic data | Standard ID | GB/T 23113-2023 (GB/T23113-2023) | | Description (Translated English) | Sample preparation for measurement of mercury level in discharge lamp | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K71 | | Classification of International Standard | 29.140.30 | | Word Count Estimation | 18,163 | | Date of Issue | 2023-11-27 | | Date of Implementation | 2024-06-01 | | Older Standard (superseded by this standard) | GB/T 23113-2017 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 23113-2023: Sample preparation for measurement of mercury level in discharge lamp---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 29:140:30
CCSK71
National Standards of People's Republic of China
Replace GB/T 23113-2017
Sample preparation for mercury content detection in discharge lamps
Published on 2023-11-27
2024-06-01 Implementation
State Administration for Market Regulation
Released by the National Standardization Administration Committee
Table of contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Overview 1
5 Procedure for collecting mercury from discharge lamps 2
5:1 General requirements 2
5:2 Reagents 2
5:3 Chemical experiment equipment 2
5:4 Sample preparation 2
5:5 Sample digestion 6
5:6 Filtering 7
6 test 7
6:1 Blank test 7
6:2 Data reporting 7
6:3 Analytical testing 7
Appendix A (Informative) Information related to the cold end method 8
Appendix B (Informative) Electrothermal Vaporization Atomic Absorption Spectrometry (EVAAS) 11
Foreword
This document complies with the provisions of GB/T 1:1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents"
Drafting:
This document replaces GB/T 23113-2017 "Sample Preparation for Detection of Mercury Content in Fluorescent Lamps": Compared with GB/T 23113-2017, except
In addition to structural adjustments and editorial changes, the main technical changes are as follows:
---Changed the scope of the file (see Chapter 1, Chapter 1 of the:2017 edition);
---Added a chapter of "Terms and Definitions" (see Chapter 3);
---"Fluorescent lamp" in the document is changed to "discharge lamp" (see Chapter 1, Chapter 4, Chapter 5, Chapter 1, Chapter 3, Chapter:2017 version
Chapter 4);
---Changed the general requirements for laboratories (see 5:1, 4:1 of the:2017 version);
---Deleted some unused chemical experimental equipment (see 4:3 of the:2017 version);
---Changed the lighting method of the cold end method (see 5:4:1:1, 4:4:1:1 of the:2017 version);
---Changed the interception method of the lamp [see 5:4:4e), 5:4:4g),:2017 version 4:4:4e), 4:4:4g)];
---Deleted redundant operations [see:2017 version 4:4:1:2h), 4:4:4];
---Changed the filtering requirements (see 5:6, 4:6 of the:2017 version);
---Changed the requirements for analytical testing (see 6:3, 5:3 of the:2017 version):
This document is modified to adopt IEC 62554:2017 "Sample Preparation for Detection of Mercury Content in Fluorescent Lamps":
Compared with IEC 62554:2017, this document has made the following structural adjustments:
---Appendix A corresponds to Appendix B in IEC 62554:2017, and Appendix B corresponds to Appendix A in IEC 62554:2017:
The technical differences between this document and IEC 62554:2017 and their reasons are as follows:
---The scope of the document has been changed (see Chapter 1, Chapter 1 of IEC 62554:2017) to adapt to the actual needs of my country's products;
---Deleted terms and their definitions (see Chapter 3 of IEC 62554:2017), and added terms referencing GB/T 2900:65 (see
Chapter 3), to adapt to my country’s technical conditions;
---Changed the general requirements for laboratories and replaced ISO /IEC 17025:2005 with GB/T 27025 (see 5:1, IEC 62554:
5:1) of:2017, to adapt to my country’s technical conditions;
---Changed the water requirements and replaced ISO 3696:1987 with GB/T 6682 (see 5:2, 5:2 of IEC 62554:2017) to suit
In response to my country’s technical conditions;
---Deleted some unused chemical experimental equipment (see 5:3 of IEC 62554:2017) to conform to actual operation;
---The lighting method of the cold end method has been changed (see 5:4:1:1, 5:4:1:1 of IEC 62554:2017) to adapt to some pipe walls during ignition
Very hot discharge lamps;
---Changed the interception method of the lamp [see 5:4:4e), 5:4:4g), IEC 62554:2017 5:4:4e), 5:4:4g)] to provide more
Light tube interception method;
---The usage concentration of nitric acid has been changed [see 5:5:2a), 5:5:2a) of IEC 62554:2017] to ensure safe use;
---Changed the requirements for analytical testing, replacing IEC 62321-4 with GB/T 39560:4 (see 6:3, IEC 62554:2017
6:3), to adapt to my country’s technical conditions:
The following editorial changes have been made to this document:
---In order to coordinate with the existing standards, the name of the standard is changed to "Sample Preparation for Detection of Mercury Content in Discharge Lamps";
---Change the permissive clauses in some notes to declarative clauses;
---Changed the upper limit of the cold end method temperature in Note 5:4:1:1;
---Changed the test method in Appendix A:
Please note that some content in this document may be subject to patents: The publisher of this document assumes no responsibility for identifying patents:
This document is proposed by China Light Industry Federation:
This document is under the jurisdiction of the National Lighting Appliances Standardization Technical Committee (SAC/TC224):
This document was drafted by: Zhongshan Quality Supervision and Inspection Institute of Guangdong Province, Shenzhen Lighting and Display Engineering Industry Association, Beijing Electro-optical
SOURCE INSTITUTE LIMITED:
The main drafters of this document: Peng Zhenjian, Jing Fajun, Zhang Bo, Wu Qiong, Fu Zhimin, Wu Xiaosen, Qiao Zhenzhong:
The previous versions of this document and the documents it replaces are as follows:
---First published as GB/T 23113-2008 in:2008, first revised in:2017;
---This is the second revision:
Sample preparation for mercury content detection in discharge lamps
1 Scope
This document specifies procedures for sample preparation and testing for the determination of mercury content in discharge lamps:
This document is applicable to the detection of mercury content (not less than 0:1 mg) in discharge lamps (including fluorescent lamps and ultraviolet lamps): Other mercury-containing discharge lamps
Refer to use:
This document does not contain all measurement information: Detailed measurement information is described in GB/T 39560:4:
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to
this document:
GB/T 2900:65 Electrical terminology lighting (GB/T 2900:65-2023, IEC 60050-845:2020, IDT)
GB/T 6682 Analytical laboratory water specifications and test methods (GB/T 6682-2008, ISO 3696:1987, MOD)
GB/T 27025 General requirements for testing and calibration laboratory capabilities (GB/T 27025-2019, ISO /IEC 17025:2017,
IDT)
GB/T 39560:4 Determination of certain substances in electronic and electrical products Part 4: CV-AAS, CV-AFS, ICP-OES and
Determination of mercury in polymers, metals and electronic parts by ICP-MS (GB/T 39560:4-2021, IEC 62321-4:2013, IDT)
3 Terms and definitions
The terms and definitions defined in GB/T 2900:65 apply to this document:
4 Overview
Mercury in discharge lamps covered by this document is present in the following states:
a) Gaseous state in the lamp;
b) liquid metal;
c) compounds;
d) Alloys:
Due to the differences in the shape, location, composition and structure of mercury-containing devices, there are various quantitative mercury injection schemes: Although some lamps contain amalgam
Mercury is injected in the form of solid amalgam or solid amalgam, but there are also many lamps in which liquid mercury is injected:
Mercury amalgam lamps often have devices that serve as auxiliary amalgams, and the shapes and placement of these devices are very diverse:
See Appendix A for instructions on how to use the cold end method to minimize the loss of vapor mercury when opening the pipe: When the lamp is in working condition, all the mercury in the lamp tube will be rich in
Concentrated at the cold end, this will help control mercury recovery:
The procedures in Chapter 5 include methods for collecting liquid mercury, combined mercury, amalgams, and amalgams:
Liquid mercury, combined mercury, amalgam and amalgam are tested to obtain the total mercury content:
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 23113-2023_English be delivered?Answer: Upon your order, we will start to translate GB/T 23113-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 23113-2023_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23113-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 23113-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23113-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|